These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 23201500)
1. A modeling approach to the effects of force guided versus depth guided compression during cardiopulmonary resuscitation on different chests and back support surfaces. Dellimore KH; Scheffer C Resuscitation; 2013 Jun; 84(6):837-42. PubMed ID: 23201500 [TBL] [Abstract][Full Text] [Related]
2. Comparison of experimental chest compression data to a theoretical model for the mechanics of constant peak displacement cardiopulmonary resuscitation. Cloete G; Dellimore KH; Scheffer C Acad Emerg Med; 2011 Nov; 18(11):1167-76. PubMed ID: 22092898 [TBL] [Abstract][Full Text] [Related]
3. Optimal chest compression in cardiopulmonary resuscitation depends upon thoracic and back support stiffness. Dellimore KH; Scheffer C Med Biol Eng Comput; 2012 Dec; 50(12):1269-78. PubMed ID: 23054380 [TBL] [Abstract][Full Text] [Related]
4. Towards optimum chest compression performance during constant peak displacement cardiopulmonary resuscitation. Dellimore KH; Cloete G; Scheffer C Med Biol Eng Comput; 2011 Sep; 49(9):1057-65. PubMed ID: 21786014 [TBL] [Abstract][Full Text] [Related]
5. The impact of backboard size and orientation on sternum-to-spine compression depth and compression stiffness in a manikin study of CPR using two mattress types. Cloete G; Dellimore KH; Scheffer C; Smuts MS; Wallis LA Resuscitation; 2011 Aug; 82(8):1064-70. PubMed ID: 21601344 [TBL] [Abstract][Full Text] [Related]
6. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques. Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Conrad CJ; Kitscha DJ; Provo TA; Lurie KG Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766 [TBL] [Abstract][Full Text] [Related]
7. Development of a real-time feedback algorithm for chest compression during CPR without assuming full chest decompression. Gohier F; Dellimore KH; Scheffer C Resuscitation; 2014 Jun; 85(6):820-5. PubMed ID: 24632512 [TBL] [Abstract][Full Text] [Related]
8. Effect of mattress deflection on CPR quality assessment for older children and adolescents. Nishisaki A; Nysaether J; Sutton R; Maltese M; Niles D; Donoghue A; Bishnoi R; Helfaer M; Perkins GD; Berg R; Arbogast K; Nadkarni V Resuscitation; 2009 May; 80(5):540-5. PubMed ID: 19342150 [TBL] [Abstract][Full Text] [Related]
9. Chest compressions by ambulance personnel on chests with variable stiffness: abilities and attitudes. Ødegaard S; Kramer-Johansen J; Bromley A; Myklebust H; Nysaether J; Wik L; Steen PA Resuscitation; 2007 Jul; 74(1):127-34. PubMed ID: 17368692 [TBL] [Abstract][Full Text] [Related]
10. Application of an anatomically-detailed finite element thorax model to investigate pediatric cardiopulmonary resuscitation techniques on hard bed. Jiang B; Mao H; Cao L; Yang KH Comput Biol Med; 2014 Sep; 52():28-34. PubMed ID: 24995425 [TBL] [Abstract][Full Text] [Related]
11. Incomplete chest wall decompression: a clinical evaluation of CPR performance by trained laypersons and an assessment of alternative manual chest compression-decompression techniques. Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Kitscha DJ; Provo TA; Lurie KG Resuscitation; 2006 Dec; 71(3):341-51. PubMed ID: 17070644 [TBL] [Abstract][Full Text] [Related]
12. Manikins with human-like chest properties--a new tool for chest compression research. Nysaether JB; Dorph E; Rafoss I; Steen PA IEEE Trans Biomed Eng; 2008 Nov; 55(11):2643-50. PubMed ID: 18990635 [TBL] [Abstract][Full Text] [Related]
13. Accurate feedback of chest compression depth on a manikin on a soft surface with correction for total body displacement. Beesems SG; Koster RW Resuscitation; 2014 Nov; 85(11):1439-43. PubMed ID: 25150184 [TBL] [Abstract][Full Text] [Related]
14. [An experimental study on the effects of rhythmic abdominal lifting and compression during cardiopulmonary resuscitation in a swine model of asphyxia]. Li XM; Wang LX; Liu YH; Sun K; Ma LZ; Guo XD; Li HQ Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2012 Apr; 24(4):237-40. PubMed ID: 22464579 [TBL] [Abstract][Full Text] [Related]
15. Does a more "physiological" infant manikin design effect chest compression quality and create a potential for thoracic over-compression during simulated infant CPR? Martin PS; Kemp AM; Theobald PS; Maguire SA; Jones MD Resuscitation; 2013 May; 84(5):666-71. PubMed ID: 23123431 [TBL] [Abstract][Full Text] [Related]
16. Active compression-decompression cardiopulmonary resuscitation (ACD-CPR) compared with standard CPR in a manikin model--decompression force, compression rate, depth and duration. Skogvoll E; Wik L Resuscitation; 1997 Feb; 34(1):11-6. PubMed ID: 9051818 [TBL] [Abstract][Full Text] [Related]
17. The impact of compliant surfaces on in-hospital chest compressions: effects of common mattresses and a backboard. Noordergraaf GJ; Paulussen IW; Venema A; van Berkom PF; Woerlee PH; Scheffer GJ; Noordergraaf A Resuscitation; 2009 May; 80(5):546-52. PubMed ID: 19409300 [TBL] [Abstract][Full Text] [Related]
18. An audiovisual feedback device for compression depth, rate and complete chest recoil can improve the CPR performance of lay persons during self-training on a manikin. Krasteva V; Jekova I; Didon JP Physiol Meas; 2011 Jun; 32(6):687-99. PubMed ID: 21606561 [TBL] [Abstract][Full Text] [Related]