183 related articles for article (PubMed ID: 23202147)
1. Evaluation of two automated immunoassays for 25-OH vitamin D: comparison against LC-MS/MS.
Hsu SA; Soldo J; Gupta M
J Steroid Biochem Mol Biol; 2013 Jul; 136():139-45. PubMed ID: 23202147
[TBL] [Abstract][Full Text] [Related]
2. Four automated 25-OH total vitamin D immunoassays and commercial liquid chromatography tandem-mass spectrometry in Finnish population.
Koivula MK; Matinlassi N; Laitinen P; Risteli J
Clin Lab; 2013; 59(3-4):397-405. PubMed ID: 23724631
[TBL] [Abstract][Full Text] [Related]
3. State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods.
Farrell CJ; Martin S; McWhinney B; Straub I; Williams P; Herrmann M
Clin Chem; 2012 Mar; 58(3):531-42. PubMed ID: 22230812
[TBL] [Abstract][Full Text] [Related]
4. Performance evaluation of four 25-hydroxyvitamin D assays to measure 25-hydroxyvitamin D2.
Freeman J; Wilson K; Spears R; Shalhoub V; Sibley P
Clin Biochem; 2015 Nov; 48(16-17):1097-104. PubMed ID: 26054580
[TBL] [Abstract][Full Text] [Related]
5. Performance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 Total 25-OH Vitamin D assays.
Chen Y; Kinney L; Božović A; Smith H; Tarr H; Diamandis EP; LeBlanc A
Clin Biochem; 2012 Nov; 45(16-17):1485-90. PubMed ID: 22705028
[TBL] [Abstract][Full Text] [Related]
6. 25-hydroxy-Vitamin D status: limitations in comparison and clinical interpretation of serum-levels across different assay methods.
Enko D; Fridrich L; Rezanka E; Stolba R; Ernst J; Wendler I; Fabian D; Hauptlorenz S; Halwachs-Baumann G
Clin Lab; 2014; 60(9):1541-50. PubMed ID: 25291951
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the analytical performance of Unicel DXI 800 for the Total 25 (OH) Vitamin D measurements.
Ozcan N; Ucar F; Arzuhal AE; Bulut E; Ozturk A; Taslipinar Yavuz M; Temel I; Erden G
Clin Biochem; 2016 Apr; 49(6):486-491. PubMed ID: 26655254
[TBL] [Abstract][Full Text] [Related]
8. Performance characteristics of six automated 25-hydroxyvitamin D assays: Mind your 3s and 2s.
Wyness SP; Straseski JA
Clin Biochem; 2015 Nov; 48(16-17):1089-96. PubMed ID: 26272200
[TBL] [Abstract][Full Text] [Related]
9. Performance of LC-MS/MS and immunoassay based 24-h urine free cortisol in the diagnosis of Cushing's syndrome.
Oßwald A; Wang R; Beuschlein F; Hartmann MF; Wudy SA; Bidlingmaier M; Zopp S; Reincke M; Ritzel K
J Steroid Biochem Mol Biol; 2019 Jun; 190():193-197. PubMed ID: 30959155
[TBL] [Abstract][Full Text] [Related]
10. Performance characteristics of the VIDAS® 25-OH Vitamin D Total assay - comparison with four immunoassays and two liquid chromatography-tandem mass spectrometry methods in a multicentric study.
Moreau E; Bächer S; Mery S; Le Goff C; Piga N; Vogeser M; Hausmann M; Cavalier E
Clin Chem Lab Med; 2016 Jan; 54(1):45-53. PubMed ID: 26124054
[TBL] [Abstract][Full Text] [Related]
11. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry.
Kocak FE; Ozturk B; Isiklar OO; Genc O; Unlu A; Altuntas I
Biochem Med (Zagreb); 2015; 25(3):430-8. PubMed ID: 26526462
[TBL] [Abstract][Full Text] [Related]
12. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.
Saleh L; Mueller D; von Eckardstein A
Clin Chem Lab Med; 2016 Apr; 54(4):617-25. PubMed ID: 26457778
[TBL] [Abstract][Full Text] [Related]
13. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays.
Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ
Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879
[TBL] [Abstract][Full Text] [Related]
14. Experience with the first fully automated chemiluminescence immunoassay for the quantification of 1α, 25-dihydroxy-vitamin D.
van Helden J; Weiskirchen R
Clin Chem Lab Med; 2015 Apr; 53(5):761-70. PubMed ID: 25274943
[TBL] [Abstract][Full Text] [Related]
15. Assessment of ADVIA Centaur analyzer for the measurement of 25-OH vitamin D.
Hermida FJ; Fernández M; Laborda B; Pérez A; Lorenzo MJ; Magadán C
Clin Lab; 2012; 58(9-10):987-95. PubMed ID: 23163115
[TBL] [Abstract][Full Text] [Related]
16. Automated Competitive Protein-Binding Assay for Total 25-OH Vitamin D, Multicenter Evaluation and Practical Performance.
Wielders JP; Carter GF; Eberl H; Morris G; Roth HJ; Vogl C
J Clin Lab Anal; 2015 Nov; 29(6):451-61. PubMed ID: 25132191
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Six Automated Immunoassays With Isotope-Diluted Liquid Chromatography-Tandem Mass Spectrometry for Total Thyroxine Measurement.
Yu S; Zhou W; Cheng X; Meng Q; Li H; Hou L; Lu J; Xie S; Cheng Q; Zhang C; Qiu L
Ann Lab Med; 2019 Jul; 39(4):381-387. PubMed ID: 30809984
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of the 25-hydroxy vitamin D assay on a fully automated liquid chromatography mass spectrometry system, the Thermo Scientific Cascadion SM Clinical Analyzer with the Cascadion 25-hydroxy vitamin D assay in a routine clinical laboratory.
Benton SC; Tetteh GK; Needham SJ; Mücke J; Sheppard L; Alderson S; Ruppen C; Curti M; Redondo M; Milan AM
Clin Chem Lab Med; 2020 Jun; 58(6):1010-1017. PubMed ID: 31851610
[TBL] [Abstract][Full Text] [Related]
19. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference.
Roth HJ; Schmidt-Gayk H; Weber H; Niederau C
Ann Clin Biochem; 2008 Mar; 45(Pt 2):153-9. PubMed ID: 18325178
[TBL] [Abstract][Full Text] [Related]
20. Comparison of four current 25-hydroxyvitamin D assays.
Moon HW; Cho JH; Hur M; Song J; Oh GY; Park CM; Yun YM; Kim JQ
Clin Biochem; 2012 Mar; 45(4-5):326-30. PubMed ID: 22244986
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]