314 related articles for article (PubMed ID: 23206607)
1. Comparison of strain ratio with elastography score system in differentiating malignant from benign thyroid nodules.
Wang H; Brylka D; Sun LN; Lin YQ; Sui GQ; Gao J
Clin Imaging; 2013; 37(1):50-5. PubMed ID: 23206607
[TBL] [Abstract][Full Text] [Related]
2. The value of strain ratio in differential diagnosis of thyroid solid nodules.
Ning CP; Jiang SQ; Zhang T; Sun LT; Liu YJ; Tian JW
Eur J Radiol; 2012 Feb; 81(2):286-91. PubMed ID: 21237598
[TBL] [Abstract][Full Text] [Related]
3. Virtual touch tissue imaging on acoustic radiation force impulse elastography: a new technique for differential diagnosis between benign and malignant thyroid nodules.
Zhang YF; He Y; Xu HX; Xu XH; Liu C; Guo LH; Liu LN; Xu JM
J Ultrasound Med; 2014 Apr; 33(4):585-95. PubMed ID: 24658938
[TBL] [Abstract][Full Text] [Related]
4. Comparison of muscle-to-nodule and parenchyma-to-nodule strain ratios in the differentiation of benign and malignant thyroid nodules: which one should we use?
Aydin R; Elmali M; Polat AV; Danaci M; Akpolat I
Eur J Radiol; 2014 Mar; 83(3):e131-6. PubMed ID: 24373836
[TBL] [Abstract][Full Text] [Related]
5. Real-time ultrasound elastography for differentiation of benign and malignant thyroid nodules: a meta-analysis.
Sun J; Cai J; Wang X
J Ultrasound Med; 2014 Mar; 33(3):495-502. PubMed ID: 24567461
[TBL] [Abstract][Full Text] [Related]
6. Ultrasonographic elastography of thyroid nodules: is adding strain ratio to colour mapping better?
Chong Y; Shin JH; Ko ES; Han BK
Clin Radiol; 2013 Dec; 68(12):1241-6. PubMed ID: 23969150
[TBL] [Abstract][Full Text] [Related]
7. Shear wave elastography versus real-time elastography on evaluation thyroid nodules: a preliminary study.
Liu BX; Xie XY; Liang JY; Zheng YL; Huang GL; Zhou LY; Wang Z; Xu M; Lu MD
Eur J Radiol; 2014 Jul; 83(7):1135-1143. PubMed ID: 24813530
[TBL] [Abstract][Full Text] [Related]
8. A threshold value in Shear Wave elastography to rule out malignant thyroid nodules: a reality?
Veyrieres JB; Albarel F; Lombard JV; Berbis J; Sebag F; Oliver C; Petit P
Eur J Radiol; 2012 Dec; 81(12):3965-72. PubMed ID: 23031543
[TBL] [Abstract][Full Text] [Related]
9. [Value of ROI A value in strain ratio and elasticity scores in differential diagnosis of thyroid nodules using ultrasonic elastography].
An X; Cong S; Qian J; Guo Y; Zhou L; Liang T
Nan Fang Yi Ke Da Xue Xue Bao; 2013 Mar; 33(3):454-7. PubMed ID: 23529253
[TBL] [Abstract][Full Text] [Related]
10. Comparison of color-Doppler and qualitative and quantitative strain-elastography for differentiation of thyroid nodules in daily practice.
Götzberger M; Krueger S; Gärtner R; Reincke M; Pichler M; Assmann G; Mussack T; Zimmermann M; Gülberg V
Hormones (Athens); 2016 Apr; 15(2):197-204. PubMed ID: 27376423
[TBL] [Abstract][Full Text] [Related]
11. Acoustic Radiation Force Impulse Elastography in the Diagnosis of Thyroid Nodules: Useful or Not Useful?
Zhang YF; Xu HX; Xu JM; Liu C; Guo LH; Liu LN; Zhang J; Xu XH; Qu S; Xing M
Ultrasound Med Biol; 2015 Oct; 41(10):2581-93. PubMed ID: 26119458
[TBL] [Abstract][Full Text] [Related]
12. Comparison of Acoustic Radiation Force Impulse Imaging and Strain Elastography in Differentiating Malignant From Benign Thyroid Nodules.
Zhang F; Zhao X; Han R; Du M; Li P; Ji X
J Ultrasound Med; 2017 Dec; 36(12):2533-2543. PubMed ID: 28646602
[TBL] [Abstract][Full Text] [Related]
13. Ultrasound elastography in the differential diagnosis of benign and malignant cervical lesions.
Lu R; Xiao Y; Liu M; Shi D
J Ultrasound Med; 2014 Apr; 33(4):667-71. PubMed ID: 24658946
[TBL] [Abstract][Full Text] [Related]
14. Thyroid nodule parameters influencing performance of ultrasound elastography using intrinsic compression.
Kim MH; Luo S; Ko SH; Bae JS; Lim J; Lim DJ; Kim Y
Ultrasound Med Biol; 2015 Sep; 41(9):2333-9. PubMed ID: 26095532
[TBL] [Abstract][Full Text] [Related]
15. Efficacy of thyroid ultrasound elastography in differential diagnosis of small thyroid nodules.
Dighe M; Luo S; Cuevas C; Kim Y
Eur J Radiol; 2013 Jun; 82(6):e274-80. PubMed ID: 23410906
[TBL] [Abstract][Full Text] [Related]
16. The utility of ultrasound elastography and MicroPure imaging in the differentiation of benign and malignant thyroid nodules.
Ciledag N; Arda K; Aribas BK; Aktas E; Köse SK
AJR Am J Roentgenol; 2012 Mar; 198(3):W244-9. PubMed ID: 22358021
[TBL] [Abstract][Full Text] [Related]
17. Distinguishing benign from malignant thyroid nodules using thyroid ultrasonography: utility of adding superb microvascular imaging and elastography.
Ahn HS; Lee JB; Seo M; Park SH; Choi BI
Radiol Med; 2018 Apr; 123(4):260-270. PubMed ID: 29249077
[TBL] [Abstract][Full Text] [Related]
18. Prospective comparative evaluation of quantitative-elastosonography (Q-elastography) and contrast-enhanced ultrasound for the evaluation of thyroid nodules: preliminary experience.
Cantisani V; Consorti F; Guerrisi A; Guerrisi I; Ricci P; Di Segni M; Mancuso E; Scardella L; Milazzo F; D'Ambrosio F; Antonaci A
Eur J Radiol; 2013 Nov; 82(11):1892-8. PubMed ID: 23928231
[TBL] [Abstract][Full Text] [Related]
19. Prospective evaluation of multiparametric ultrasound and quantitative elastosonography in the differential diagnosis of benign and malignant thyroid nodules: preliminary experience.
Cantisani V; D'Andrea V; Biancari F; Medvedyeva O; Di Segni M; Olive M; Patrizi G; Redler A; De Antoni E E; Masciangelo R; Frezzotti F; Ricci P
Eur J Radiol; 2012 Oct; 81(10):2678-83. PubMed ID: 22357195
[TBL] [Abstract][Full Text] [Related]
20. Ultrasound elastography using carotid artery pulsation in the differential diagnosis of sonographically indeterminate thyroid nodules.
Choi WJ; Park JS; Koo HR; Kim SY; Chung MS; Tae K
AJR Am J Roentgenol; 2015 Feb; 204(2):396-401. PubMed ID: 25615763
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]