These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
92 related articles for article (PubMed ID: 2320752)
1. Computer-aided construction and quantitative evaluation of missing-tissue compensators. Kuchnir FT; Myrianthopoulos LC; Lossin E Radiother Oncol; 1990 Mar; 17(3):239-47. PubMed ID: 2320752 [TBL] [Abstract][Full Text] [Related]
2. Computer aided design and verification of megavoltage tissue compensators for oblique beams. Faddegon BA; Pfalzner P Med Phys; 1988; 15(5):757-62. PubMed ID: 3141758 [TBL] [Abstract][Full Text] [Related]
3. Missing tissue compensators: evaluation and optimization of a commercial system. Ansbacher W; Robinson DM; Scrimger JW Med Phys; 1992; 19(5):1267-72. PubMed ID: 1435608 [TBL] [Abstract][Full Text] [Related]
4. Use of intensity modulation for missing tissue compensation of pediatric spinal fields. Phillips MH; Cho PS; Parsai H; Douglas JG J Appl Clin Med Phys; 2003; 4(4):274-81. PubMed ID: 14604416 [TBL] [Abstract][Full Text] [Related]
5. Use of a multileaf collimator as a dynamic missing-tissue compensator. Geis P; Boyer AL; Wells NH Med Phys; 1996 Jul; 23(7):1199-205. PubMed ID: 8839413 [TBL] [Abstract][Full Text] [Related]
6. A dosimetric comparison of three compensator design methods for the mantle field. Cantwell JP; Renner WD; O'Connor TP; Bermudez NM Med Dosim; 1989 Dec; 14(4):257-63. PubMed ID: 2513827 [TBL] [Abstract][Full Text] [Related]
7. Clinical considerations in the use of missing tissue compensators for head and neck cases. Sharma SC; Johnson MW Med Dosim; 1998; 23(4):267-70. PubMed ID: 9863724 [TBL] [Abstract][Full Text] [Related]
8. [Evaluation of compensator used in radiation therapy]. Lin FJ; Cheng NT; Chen HH; Chen CS; Hsien WL; Leung WM Changgeng Yi Xue Za Zhi; 1990 Jun; 13(2):104-17. PubMed ID: 2224603 [TBL] [Abstract][Full Text] [Related]
9. Tissue compensation and verification of dose uniformity. Park HC; Almond PR Med Dosim; 1993; 18(4):193-6. PubMed ID: 8311915 [TBL] [Abstract][Full Text] [Related]
10. Description and evaluation of a new 3-D computerized treatment planning dose compensator system. Beddar AS; Thomason C; Leung PM Med Dosim; 1994; 19(4):227-35. PubMed ID: 7893357 [TBL] [Abstract][Full Text] [Related]
12. Tissue compensators made of solid water or lead for megavoltage X-ray radiotherapy. Constantinou C; Harrington JC Med Dosim; 1989; 14(1):41-7. PubMed ID: 2500947 [TBL] [Abstract][Full Text] [Related]
13. Limitations of retracted missing tissue compensators: an experimental analysis. Robinson DM; Scrimger JW Med Dosim; 1989; 14(1):49-54. PubMed ID: 2500948 [TBL] [Abstract][Full Text] [Related]
14. Tissue compensator fabrication using a simple photographic technique. Lam WC; Lam KS; Lee DJ; O'Neill MJ Radiology; 1983 Oct; 149(1):322-3. PubMed ID: 6412282 [TBL] [Abstract][Full Text] [Related]
15. Inclusion of compensator-induced scatter and beam filtration in pencil beam dose calculations. du Plessis FC; Willemse CA Med Phys; 2006 Aug; 33(8):2896-904. PubMed ID: 16964866 [TBL] [Abstract][Full Text] [Related]
16. Clinical considerations in the use of missing tissue compensators for thoracic cases. Sharma SC; Johnson MW Med Dosim; 1997; 22(2):107-12. PubMed ID: 9243463 [TBL] [Abstract][Full Text] [Related]
17. [Design, development, and dosage control of individual compensatory filters for 6 MV X-ray radiotherapy]. Zonca G; Loi G; Somigliana A; Filice S; Crippa M; Manciero S; Stucchi C; Poste D; Sichirollo AE Radiol Med; 1995 May; 89(5):695-701. PubMed ID: 7617914 [TBL] [Abstract][Full Text] [Related]
18. Accuracy of dose calculation methods for retracted tissue compensators. Gray K; Smith CW Phys Med Biol; 1994 Dec; 39(12):2355-65. PubMed ID: 15551559 [TBL] [Abstract][Full Text] [Related]