These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 23208532)

  • 1. A method to derive appropriate exposure parameters from target exposure index and patient thickness in pediatric digital radiography.
    Zhang M; Liu K; Niu X; Liu X
    Pediatr Radiol; 2013 Mar; 43(5):568-74. PubMed ID: 23208532
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of added filtration on radiation dose and image quality in digital radiography of newborns.
    Papadakis AE; Giannakaki V; Hatzidaki E; Damilakis J
    Pediatr Radiol; 2023 Sep; 53(10):2060-2068. PubMed ID: 37310445
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of Projections on Radiation Dose for and Image Quality of Chest Digital Radiography for Children.
    Xu H; Liu B; Cai J; Zheng H; Zheng H; Yang Q; Yao C
    Curr Med Imaging; 2021; 17(12):1496-1502. PubMed ID: 34264186
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of four methods for assessing patient effective dose from radiological examinations.
    Theocharopoulos N; Perisinakis K; Damilakis J; Varveris H; Gourtsoyiannis N
    Med Phys; 2002 Sep; 29(9):2070-9. PubMed ID: 12349928
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of the use of various imaging units and projections on the radiation dose received by children during chest digital radiography.
    Xu H; Huang K; Liu B; Cai J; Zheng H; Zheng H; Yang Q; Yao C
    PLoS One; 2021; 16(8):e0255749. PubMed ID: 34352022
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dose reduction in a paediatric X-ray department following optimization of radiographic technique.
    Mooney R; Thomas PS
    Br J Radiol; 1998 Aug; 71(848):852-60. PubMed ID: 9828798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Local reference dose evaluation in conventional radiography examinations in Iran.
    Shirin Shandiz M; Bahreyni Toosi MT; Farsi S; Yaghobi K
    J Appl Clin Med Phys; 2014 Mar; 15(2):4550. PubMed ID: 24710442
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of dose-area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria.
    Jibiri NN; Olowookere CJ
    J Appl Clin Med Phys; 2016 Nov; 17(6):392-404. PubMed ID: 27929511
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dose levels from thoracic and pelvic examinations in two pediatric radiological departments in Norway - a comparison study of dose-area product and radiographic technique.
    Sæther HK; Lagesen B; Trægde Martinsen AC; Holsen EP; Øvrebø KM
    Acta Radiol; 2010 Dec; 51(10):1137-42. PubMed ID: 20860497
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimization of the radiological protection of patients undergoing digital radiography.
    Zhang M; Chu C
    J Digit Imaging; 2012 Feb; 25(1):196-200. PubMed ID: 21725621
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparing the standard knee X-ray exposure factor, 10 kV rule, and modified 10 kV rule techniques in digital radiography to reduce patient radiation dose without loss of image quality.
    Wenman A; Lockwood P
    Radiography (Lond); 2024 Mar; 30(2):574-581. PubMed ID: 38295494
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Potentials of additional copper filtration on radiation dose and image quality for adults underwent digital chest X-ray imaging in Dubai Health Authority - UAE.
    Siraj M; Dalah EZ; Okasha MH; Abdel Kader GI; Mohamed Said MS; Kalanter RA; Razack HA; Mohamad Ahmad AN; Albastaki AA
    Radiography (Lond); 2023 May; 29(3):552-556. PubMed ID: 36958232
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Radiation exposure of children in pediatric radiology--part 2: the PAEDOS algorithm for computer-assisted dose reconstruction in pediatric radiology and results for X-ray examinations of the skull].
    Seidenbusch MC; Regulla D; Schneider K
    Rofo; 2008 Jun; 180(6):522-39. PubMed ID: 18484514
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values.
    Ubeda C; Miranda P; Vano E
    Med Phys; 2015 Feb; 42(2):615-622. PubMed ID: 28102608
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of Pediatrics Radiation Dose from Routine X-Ray Examination at Jimma University Hospital, Southwest Ethiopia.
    Zewdu M; Kadir E; Berhane M
    Ethiop J Health Sci; 2017 Sep; 27(5):481-490. PubMed ID: 29217953
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A dose index as a tool to estimate paediatric patient doses in digital projection radiography.
    Garcia Castañon P; España Lopez ML; Fernandez Bedoya V; Bermudez Luna R; Rodriguez Martin G
    Radiat Prot Dosimetry; 2012 May; 149(4):417-23. PubMed ID: 21775320
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The validity and reliability of the exposure index as a metric for estimating the radiation dose to the patient.
    Erenstein HG; Browne D; Curtin S; Dwyer RS; Higgins RN; Hommel SF; Menzinga J; Pires Jorge JA; Sauty M; de Vries G; England A
    Radiography (Lond); 2020 Oct; 26 Suppl 2():S94-S99. PubMed ID: 32291123
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Proper Management of the Clinical Exposure Index Based on Body Thickness Using Dose Optimization Tools in Digital Chest Radiography: A Phantom Study.
    Yoon Y; Park H; Kim J; Kim J; Roh Y; Tanaka N; Morishita J
    Int J Environ Res Public Health; 2021 May; 18(10):. PubMed ID: 34068390
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monitoring clinical exposure index and deviation index for dose optimization based on national diagnostic reference level: Focusing on general radiography of extremities.
    Park H; Yoon Y; Kim E; Jeong H; Kim J
    J Xray Sci Technol; 2022; 30(3):419-432. PubMed ID: 35124635
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction.
    Hufton AP; Doyle SM; Carty HM
    Br J Radiol; 1998 Feb; 71(842):186-99. PubMed ID: 9579183
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.