These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 23216058)

  • 21. Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews - an in vitro study.
    Tepedino M; Masedu F; Chimenti C
    Head Face Med; 2017 May; 13(1):10. PubMed ID: 28558821
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of cortical thickness on the stability of mini-implants with microthreads.
    Vilani GN; Ruellas AC; Mattos CT; Fernandes DJ; Elias CN
    Braz Oral Res; 2015; 29():. PubMed ID: 25627887
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of size and insertion angle of orthodontic mini-implants on skeletal anchorage.
    Tatli U; Alraawi M; Toroğlu MS
    Am J Orthod Dentofacial Orthop; 2019 Aug; 156(2):220-228. PubMed ID: 31375232
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.
    Çehreli S; Arman-Özçırpıcı A
    Am J Orthod Dentofacial Orthop; 2012 Feb; 141(2):187-95. PubMed ID: 22284286
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical properties of orthodontic miniscrews. An in-vitro study.
    Florvaag B; Kneuertz P; Lazar F; Koebke J; Zöller JE; Braumann B; Mischkowski RA
    J Orofac Orthop; 2010 Jan; 71(1):53-67. PubMed ID: 20135250
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Placement and removal torque values of orthodontic miniscrew implants.
    Suzuki EY; Suzuki B
    Am J Orthod Dentofacial Orthop; 2011 May; 139(5):669-78. PubMed ID: 21536211
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mechanical strength of orthodontic infrazygomatic mini-implants.
    Wang CH; Wu JH; Lee KT; Hsu KR; Wang HC; Chen CM
    Odontology; 2011 Jan; 99(1):98-100. PubMed ID: 21271334
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An in vitro investigation of peak insertion torque values of six commercially available mini-implants.
    Whang CZ; Bister D; Sherriff M
    Eur J Orthod; 2011 Dec; 33(6):660-6. PubMed ID: 21186241
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of acid etching and calcium chloride immersion on removal torque and bone-cutting ability of orthodontic mini-implants.
    Jang TH; Park JH; Moon W; Chae JM; Chang NY; Kang KH
    Am J Orthod Dentofacial Orthop; 2018 Jul; 154(1):108-114. PubMed ID: 29957307
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Mechanical evaluation of orthodontic mini-implants of different lengths.
    Pithon MM; Figueiredo DS; Oliveira DD
    J Oral Maxillofac Surg; 2013 Mar; 71(3):479-86. PubMed ID: 23273488
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effects of the taper shape, dual-thread, and length on the mechanical properties of mini-implants.
    Kim YK; Kim YJ; Yun PY; Kim JW
    Angle Orthod; 2009 Sep; 79(5):908-14. PubMed ID: 19705930
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage.
    Wilmes B; Drescher D
    Int J Oral Maxillofac Surg; 2011 Jul; 40(7):697-703. PubMed ID: 21458232
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Pitch and longitudinal fluting effects on the primary stability of miniscrew implants.
    Brinley CL; Behrents R; Kim KB; Condoor S; Kyung HM; Buschang PH
    Angle Orthod; 2009 Nov; 79(6):1156-61. PubMed ID: 19852609
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Experimental investigation of the fracture torque of orthodontic anchorage screws.
    Reimann S; Ayubi M; McDonald F; Bourauel C
    J Orofac Orthop; 2016 Jul; 77(4):272-80. PubMed ID: 27098641
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effects of thread shape on the pullout strength of miniscrews.
    Gracco A; Giagnorio C; Incerti Parenti S; Alessandri Bonetti G; Siciliani G
    Am J Orthod Dentofacial Orthop; 2012 Aug; 142(2):186-90. PubMed ID: 22858327
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Morphological evaluation of the active tip of six types of orthodontic mini-implants.
    Kitahara-Céia FM; Assad-Loss TF; Mucha JN; Elias CN
    Dental Press J Orthod; 2013; 18(2):36-41. PubMed ID: 23916430
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of primary stability of used and unused self-tapping and self-drilling orthodontic mini-implants.
    Baser B; Ozel MB
    Adv Clin Exp Med; 2024 May; 33(5):483-489. PubMed ID: 37676101
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optimal asymmetric thread for orthodontic microimplants: Laboratory and clinical evaluation.
    Alrbata RH; Ha DW; Yu W; Kyung HM
    Angle Orthod; 2015 Jul; 85(4):585-90. PubMed ID: 25286340
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vitro evaluation of insertion and removal torques of orthodontic mini-implants.
    Pithon MM; Nojima MG; Nojima LI
    Int J Oral Maxillofac Surg; 2011 Jan; 40(1):80-5. PubMed ID: 21050721
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of expansion forces of five pure bone-borne maxillary expander designs anchored with orthodontic mini-implants: An in vitro study.
    Walter A; de la Iglesia F; Winsauer H; Ploder O; Wendl B; Puigdollers Perez A
    J Orthod; 2023 Dec; 50(4):335-343. PubMed ID: 36786416
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.