714 related articles for article (PubMed ID: 23219454)
1. Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: a phantom study.
Schindera ST; Winklehner A; Alkadhi H; Goetti R; Fischer M; Gnannt R; Szucs-Farkas Z
Clin Radiol; 2013 Feb; 68(2):e79-86. PubMed ID: 23219454
[TBL] [Abstract][Full Text] [Related]
2. Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study.
Schindera ST; Nelson RC; Yoshizumi T; Toncheva G; Nguyen G; DeLong DM; Szucs-Farkas Z
Acad Radiol; 2009 Aug; 16(8):997-1002. PubMed ID: 19409820
[TBL] [Abstract][Full Text] [Related]
3. Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study.
Szucs-Farkas Z; Verdun FR; von Allmen G; Mini RL; Vock P
Invest Radiol; 2008 Jun; 43(6):374-81. PubMed ID: 18496042
[TBL] [Abstract][Full Text] [Related]
4. Automated low-kilovoltage selection in pediatric computed tomography angiography: phantom study evaluating effects on radiation dose and image quality.
Siegel MJ; Ramirez-Giraldo JC; Hildebolt C; Bradley D; Schmidt B
Invest Radiol; 2013 Aug; 48(8):584-9. PubMed ID: 23563195
[TBL] [Abstract][Full Text] [Related]
5. Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study.
Schindera ST; Diedrichsen L; Müller HC; Rusch O; Marin D; Schmidt B; Raupach R; Vock P; Szucs-Farkas Z
Radiology; 2011 Aug; 260(2):454-62. PubMed ID: 21493795
[TBL] [Abstract][Full Text] [Related]
6. Circle of Willis at CT angiography: dose reduction and image quality--reducing tube voltage and increasing tube current settings.
Waaijer A; Prokop M; Velthuis BK; Bakker CJ; de Kort GA; van Leeuwen MS
Radiology; 2007 Mar; 242(3):832-9. PubMed ID: 17229873
[TBL] [Abstract][Full Text] [Related]
7. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.
Siegel MJ; Schmidt B; Bradley D; Suess C; Hildebolt C
Radiology; 2004 Nov; 233(2):515-22. PubMed ID: 15358847
[TBL] [Abstract][Full Text] [Related]
8. Endoleak detection with CT angiography in an abdominal aortic aneurysm phantom: effect of tube energy, simulated patient size, and physical properties of endoleaks.
Szucs-Farkas Z; Semadeni M; Bensler S; Patak MA; von Allmen G; Vock P; Schindera ST
Radiology; 2009 May; 251(2):590-8. PubMed ID: 19401582
[TBL] [Abstract][Full Text] [Related]
9. Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: a comparative analysis of image quality and radiation exposure.
Stiller W; Schwarzwaelder CB; Sommer CM; Veloza S; Radeleff BA; Kauczor HU
Eur J Radiol; 2012 Jul; 81(7):1405-12. PubMed ID: 21458939
[TBL] [Abstract][Full Text] [Related]
10. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study.
Papadakis AE; Perisinakis K; Raissaki M; Damilakis J
Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518
[TBL] [Abstract][Full Text] [Related]
11. Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study.
Kalva SP; Sahani DV; Hahn PF; Saini S
J Comput Assist Tomogr; 2006; 30(3):391-7. PubMed ID: 16778612
[TBL] [Abstract][Full Text] [Related]
12. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.
Marin D; Nelson RC; Schindera ST; Richard S; Youngblood RS; Yoshizumi TT; Samei E
Radiology; 2010 Jan; 254(1):145-53. PubMed ID: 20032149
[TBL] [Abstract][Full Text] [Related]
13. Assessment of image quality on effects of varying tube voltage and automatic tube current modulation with hybrid and pure iterative reconstruction techniques in abdominal/pelvic CT: a phantom study.
Vardhanabhuti V; Loader R; Roobottom CA
Invest Radiol; 2013 Mar; 48(3):167-74. PubMed ID: 23344519
[TBL] [Abstract][Full Text] [Related]
14. Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: an in vitro and in vivo study.
Schindera ST; Tock I; Marin D; Nelson RC; Raupach R; Hagemeister M; von Allmen G; Vock P; Szucs-Farkas Z
Radiology; 2010 Aug; 256(2):528-35. PubMed ID: 20656839
[TBL] [Abstract][Full Text] [Related]
15. Nonlinear three-dimensional noise filter with low-dose CT angiography: effect on the detection of small high-contrast objects in a phantom model.
Szucs-Farkas Z; Bensler S; Torrente JC; Cullmann JL; Vock P; Schindera ST
Radiology; 2011 Jan; 258(1):261-9. PubMed ID: 21062921
[TBL] [Abstract][Full Text] [Related]
16. Using 100- instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality.
Björkdahl P; Nyman U
Acta Radiol; 2010 Apr; 51(3):260-70. PubMed ID: 20121673
[TBL] [Abstract][Full Text] [Related]
17. Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose.
Schindera ST; Graca P; Patak MA; Abderhalden S; von Allmen G; Vock P; Szucs-Farkas Z
Invest Radiol; 2009 Oct; 44(10):650-5. PubMed ID: 19724236
[TBL] [Abstract][Full Text] [Related]
18. Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
Gordic S; Morsbach F; Schmidt B; Allmendinger T; Flohr T; Husarik D; Baumueller S; Raupach R; Stolzmann P; Leschka S; Frauenfelder T; Alkadhi H
Invest Radiol; 2014 Jul; 49(7):465-73. PubMed ID: 24598443
[TBL] [Abstract][Full Text] [Related]
19. Dose reduction for CT coronary calcium scoring with a calcium-aware image reconstruction technique: a phantom study.
Booij R; van der Werf NR; Budde RPJ; Bos D; van Straten M
Eur Radiol; 2020 Jun; 30(6):3346-3355. PubMed ID: 32072259
[TBL] [Abstract][Full Text] [Related]
20. Feasibility study of low tube voltage (80 kVp) coronary CT angiography combined with contrast medium reduction using iterative model reconstruction (IMR) on standard BMI patients.
Zhang F; Yang L; Song X; Li YN; Jiang Y; Zhang XH; Ju HY; Wu J; Chang RP
Br J Radiol; 2016; 89(1058):20150766. PubMed ID: 26607646
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]