These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
103 related articles for article (PubMed ID: 23221322)
1. On the validity of 3D polymer gel dosimetry: II. physico-chemical effects. Vandecasteele J; De Deene Y Phys Med Biol; 2013 Jan; 58(1):43-61. PubMed ID: 23221322 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification. Vandecasteele J; De Deene Y Phys Med Biol; 2013 Sep; 58(18):6241-62. PubMed ID: 23965800 [TBL] [Abstract][Full Text] [Related]
3. On the validity of 3D polymer gel dosimetry: III. MRI-related error sources. Vandecasteele J; De Deene Y Phys Med Biol; 2013 Jan; 58(1):63-85. PubMed ID: 23221352 [TBL] [Abstract][Full Text] [Related]
4. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry. MacDougall ND; Pitchford WG; Smith MA Phys Med Biol; 2002 Oct; 47(20):R107-21. PubMed ID: 12433119 [TBL] [Abstract][Full Text] [Related]
5. On the validity of 3D polymer gel dosimetry: I. reproducibility study. Vandecasteele J; De Deene Y Phys Med Biol; 2013 Jan; 58(1):19-42. PubMed ID: 23221300 [TBL] [Abstract][Full Text] [Related]
6. Basic investigations on the performance of a normoxic polymer gel with tetrakis-hydroxy-methyl-phosphonium chloride as an oxygen scavenger: reproducibility, accuracy, stability, and dose rate dependence. Bayreder C; Georg D; Moser E; Berg A Med Phys; 2006 Jul; 33(7):2506-18. PubMed ID: 16898454 [TBL] [Abstract][Full Text] [Related]
7. Differential dose volume histograms of Gamma knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation. Pourfallah TA; Allahverdi M; Alam NR; Ay MR; Zahmatkesh MH Med Phys; 2009 Jul; 36(7):3002-12. PubMed ID: 19673199 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of the dosimetric performance of BANG3 polymer gel. MacDougall ND; Miquel ME; Wilson DJ; Keevil SF; Smith MA Phys Med Biol; 2005 Apr; 50(8):1717-26. PubMed ID: 15815092 [TBL] [Abstract][Full Text] [Related]
9. Application of high field magnetic resonance microimaging in polymer gel dosimetry. Skorupa A; Woźnica A; Ciszek M; Staniszewski M; Kijonka M; Kozicki M; Woźniak B; Orlef A; Polański A; Boguszewicz Ł; Sokół M Med Phys; 2020 Aug; 47(8):3600-3613. PubMed ID: 32301510 [TBL] [Abstract][Full Text] [Related]
10. Absolute dosimetry with polymer gels-a TLD reference system. Mann P; Schwahofer A; Karger CP Phys Med Biol; 2019 Feb; 64(4):045010. PubMed ID: 30630134 [TBL] [Abstract][Full Text] [Related]
11. Characteristics of a novel polymer gel dosimeter formula for MRI scanning: Dosimetry, toxicity and temporal stability of response. Abtahi SM Phys Med; 2016 Sep; 32(9):1156-61. PubMed ID: 27542576 [TBL] [Abstract][Full Text] [Related]
12. The application of polymer gel dosimeters to dosimetry for targeted radionuclide therapy. Gear JI; Flux GD; Charles-Edwards E; Partridge M; Cook G; Ott RJ Phys Med Biol; 2006 Jul; 51(14):3503-16. PubMed ID: 16825745 [TBL] [Abstract][Full Text] [Related]
14. Performance evaluation of MRI-based PAGAT polymer gel dosimeter in an inhomogeneous phantom using EGSnrc code on a Co-60 machine. Pourfallah TA; Allahverdi M; Alam NR; Ay MR; Zahmatkesh MH; Ibbott GS Appl Radiat Isot; 2009 Jan; 67(1):186-91. PubMed ID: 18951810 [TBL] [Abstract][Full Text] [Related]
15. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels. Khan M; Heilemann G; Kuess P; Georg D; Berg A Phys Med Biol; 2018 Mar; 63(6):06NT01. PubMed ID: 29528035 [TBL] [Abstract][Full Text] [Related]
16. Technical Note: Radiotherapy dose characterization of gel dosimetry using shear wave elasticity imaging. Xie WH; Su CT; Kao YJ; Chang TH; Chang YJ; Yao CH; Hsieh BY Med Phys; 2020 Mar; 47(3):1404-1410. PubMed ID: 31950500 [TBL] [Abstract][Full Text] [Related]
17. Dosimetric characteristics of a new polymer gel and their dependence on post-preparation and post-irradiation time: effect on X-ray beam profile measurements. Papoutsaki MV; Maris TG; Pappas E; Papadakis AE; Damilakis J Phys Med; 2013 Sep; 29(5):453-60. PubMed ID: 23375524 [TBL] [Abstract][Full Text] [Related]
18. An evaluation of the dosimetric performance characteristics of N-vinylpyrrolidone-based polymer gels. Papadakis AE; Maris TG; Zacharopoulou F; Pappas E; Zacharakis G; Damilakis J Phys Med Biol; 2007 Aug; 52(16):5069-83. PubMed ID: 17671354 [TBL] [Abstract][Full Text] [Related]
19. The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels. De Deene Y; Vergote K; Claeys C; De Wagter C Phys Med Biol; 2006 Feb; 51(3):653-73. PubMed ID: 16424587 [TBL] [Abstract][Full Text] [Related]
20. Effects of phantom volume and shape on the accuracy of MRI BANG gel dosimetry using BANG3. MacDougall ND; Miquel ME; Keevil SF Br J Radiol; 2008 Jan; 81(961):46-50. PubMed ID: 17998279 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]