BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 23230974)

  • 1. Correlation of age and HRT use with breast density as assessed by Quantra™.
    Skippage P; Wilkinson L; Allen S; Roche N; Dowsett M; A'hern R
    Breast J; 2013; 19(1):79-86. PubMed ID: 23230974
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Volumetric quantification of the effect of aging and hormone replacement therapy on breast composition from digital mammograms.
    Hammann-Kloss JS; Bick U; Fallenberg E; Engelken F
    Eur J Radiol; 2014 Jul; 83(7):1092-1097. PubMed ID: 24788077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Type 2 diabetes and mammographic breast density among underserved women.
    Sanderson M; O'Hara H; Foderingham N; Dupont WD; Shu XO; Peterson N; Fair AM; Disher AC
    Cancer Causes Control; 2015 Feb; 26(2):303-309. PubMed ID: 25421380
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Digital mammographic density and breast cancer risk: a case-control study of six alternative density assessment methods.
    Eng A; Gallant Z; Shepherd J; McCormack V; Li J; Dowsett M; Vinnicombe S; Allen S; dos-Santos-Silva I
    Breast Cancer Res; 2014 Sep; 16(5):439. PubMed ID: 25239205
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiological assessment of breast density by visual classification (BI-RADS) compared to automated volumetric digital software (Quantra): implications for clinical practice.
    Regini E; Mariscotti G; Durando M; Ghione G; Luparia A; Campanino PP; Bianchi CC; Bergamasco L; Fonio P; Gandini G
    Radiol Med; 2014 Oct; 119(10):741-9. PubMed ID: 24610166
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of percent density from raw and processed full-field digital mammography data.
    Vachon CM; Fowler EE; Tiffenberg G; Scott CG; Pankratz VS; Sellers TA; Heine JJ
    Breast Cancer Res; 2013 Jan; 15(1):R1. PubMed ID: 23289950
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality.
    Østerås BH; Skaane P; Gullien R; Martinsen ACT
    Phys Med Biol; 2018 Jan; 63(3):035006. PubMed ID: 29311416
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automated Breast Density Computation in Digital Mammography and Digital Breast Tomosynthesis: Influence on Mean Glandular Dose and BIRADS Density Categorization.
    Castillo-García M; Chevalier M; Garayoa J; Rodriguez-Ruiz A; García-Pinto D; Valverde J
    Acad Radiol; 2017 Jul; 24(7):802-810. PubMed ID: 28214227
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of lifestyle factors on mammographic density in postmenopausal women.
    Brand JS; Czene K; Eriksson L; Trinh T; Bhoo-Pathy N; Hall P; Celebioglu F
    PLoS One; 2013; 8(12):e81876. PubMed ID: 24349146
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of mammogram acquisition on the mammographic density and breast cancer association in the Mayo Mammography Health Study cohort.
    Olson JE; Sellers TA; Scott CG; Schueler BA; Brandt KR; Serie DJ; Jensen MR; Wu FF; Morton MJ; Heine JJ; Couch FJ; Pankratz VS; Vachon CM
    Breast Cancer Res; 2012 Nov; 14(6):R147. PubMed ID: 23152984
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated measurement of volumetric mammographic density: a tool for widespread breast cancer risk assessment.
    Brand JS; Czene K; Shepherd JA; Leifland K; Heddson B; Sundbom A; Eriksson M; Li J; Humphreys K; Hall P
    Cancer Epidemiol Biomarkers Prev; 2014 Sep; 23(9):1764-72. PubMed ID: 25012995
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Semi-automated and fully automated mammographic density measurement and breast cancer risk prediction.
    Llobet R; Pollán M; Antón J; Miranda-García J; Casals M; Martínez I; Ruiz-Perales F; Pérez-Gómez B; Salas-Trejo D; Pérez-Cortés JC
    Comput Methods Programs Biomed; 2014 Sep; 116(2):105-15. PubMed ID: 24636804
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of statin use on volumetric mammographic density: results from the KARMA study.
    Skarping I; Brand JS; Hall P; Borgquist S
    BMC Cancer; 2015 May; 15():435. PubMed ID: 26016855
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection.
    Chiarelli AM; Prummel MV; Muradali D; Shumak RS; Majpruz V; Brown P; Jiang H; Done SJ; Yaffe MJ
    Breast Cancer Res Treat; 2015 Nov; 154(2):377-87. PubMed ID: 26518019
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of a fully automated, high-throughput mammographic density measurement tool for use with processed digital mammograms.
    Couwenberg AM; Verkooijen HM; Li J; Pijnappel RM; Charaghvandi KR; Hartman M; van Gils CH
    Cancer Causes Control; 2014 Aug; 25(8):1037-43. PubMed ID: 24962023
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.
    Duffy SW; Morrish OWE; Allgood PC; Black R; Gillan MGC; Willsher P; Cooke J; Duncan KA; Michell MJ; Dobson HM; Maroni R; Lim YY; Purushothaman HN; Suaris T; Astley SM; Young KC; Tucker L; Gilbert FJ
    Eur J Cancer; 2018 Jan; 88():48-56. PubMed ID: 29190506
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantra™ should be considered a tool for two-grade scale mammographic breast density classification.
    Ekpo EU; McEntee MF; Rickard M; Brennan PC; Kunduri J; Demchig D; Mello-Thoms C
    Br J Radiol; 2016; 89(1060):20151057. PubMed ID: 26882045
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of Clinical and Automated Breast Density Measurements: Implications for Risk Prediction and Supplemental Screening.
    Brandt KR; Scott CG; Ma L; Mahmoudzadeh AP; Jensen MR; Whaley DH; Wu FF; Malkov S; Hruska CB; Norman AD; Heine J; Shepherd J; Pankratz VS; Kerlikowske K; Vachon CM
    Radiology; 2016 Jun; 279(3):710-9. PubMed ID: 26694052
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Inter-observer agreement according to three methods of evaluating mammographic density and parenchymal pattern in a case control study: impact on relative risk of breast cancer.
    Winkel RR; von Euler-Chelpin M; Nielsen M; Diao P; Nielsen MB; Uldall WY; Vejborg I
    BMC Cancer; 2015 Apr; 15():274. PubMed ID: 25884160
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [THE EFFECTS OF HORMONAL REPLACEMENT THERAPY (HRT) ON MAMMOGRAPHIC BREAST DENSITY AND ABNORMAL MAMMOGRAMS PROMPTING FURTHER INVESTIGATION].
    Barda L; Nevler A; Rosin D; Shabtai EL; Gutman M; Shabtai M
    Harefuah; 2019 Apr; 158(4):239-243. PubMed ID: 31032556
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.