These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT). Jin JY; Ren L; Liu Q; Kim J; Wen N; Guan H; Movsas B; Chetty IJ Med Phys; 2010 Nov; 37(11):5634-44. PubMed ID: 21158275 [TBL] [Abstract][Full Text] [Related]
5. Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images. Niu T; Sun M; Star-Lack J; Gao H; Fan Q; Zhu L Med Phys; 2010 Oct; 37(10):5395-406. PubMed ID: 21089775 [TBL] [Abstract][Full Text] [Related]
6. Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid. Stankovic U; van Herk M; Ploeger LS; Sonke JJ Med Phys; 2014 Jun; 41(6):061910. PubMed ID: 24877821 [TBL] [Abstract][Full Text] [Related]
7. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study. Ning R; Tang X; Conover D; Yu R Med Phys; 2003 Jul; 30(7):1694-705. PubMed ID: 12906186 [TBL] [Abstract][Full Text] [Related]
8. Volume-of-interest cone-beam CT using a 2.35 MV beam generated with a carbon target. Robar JL; Parsons D; Berman A; Macdonald A Med Phys; 2012 Jul; 39(7):4209-18. PubMed ID: 22830754 [TBL] [Abstract][Full Text] [Related]
9. Feasibility study of a synchronized-moving-grid (SMOG) system to improve image quality in cone-beam computed tomography (CBCT). Ren L; Yin FF; Chetty IJ; Jaffray DA; Jin JY Med Phys; 2012 Aug; 39(8):5099-110. PubMed ID: 22894435 [TBL] [Abstract][Full Text] [Related]
12. Scatter correction for cone-beam computed tomography using moving blocker strips: a preliminary study. Wang J; Mao W; Solberg T Med Phys; 2010 Nov; 37(11):5792-800. PubMed ID: 21158291 [TBL] [Abstract][Full Text] [Related]
13. Binary moving-blocker-based scatter correction in cone-beam computed tomography with width-truncated projections: proof of concept. Lee H; Fahimian BP; Xing L Phys Med Biol; 2017 Mar; 62(6):2176-2193. PubMed ID: 28079527 [TBL] [Abstract][Full Text] [Related]
14. Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information. Lee H; Xing L; Lee R; Fahimian BP Med Phys; 2012 May; 39(5):2386-95. PubMed ID: 22559608 [TBL] [Abstract][Full Text] [Related]
15. A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. Siewerdsen JH; Daly MJ; Bakhtiar B; Moseley DJ; Richard S; Keller H; Jaffray DA Med Phys; 2006 Jan; 33(1):187-97. PubMed ID: 16485425 [TBL] [Abstract][Full Text] [Related]
16. Multi-energy blended CBCT spectral imaging and scatter-decoupled material decomposition using a spectral modulator with flying focal spot (SMFFS). Deng Y; Zhou H; Wang Z; Wang AS; Gao H Med Phys; 2024 Apr; 51(4):2398-2412. PubMed ID: 38477717 [TBL] [Abstract][Full Text] [Related]
17. X-ray scatter correction algorithm for cone beam CT imaging. Ning R; Tang X; Conover D Med Phys; 2004 May; 31(5):1195-202. PubMed ID: 15191309 [TBL] [Abstract][Full Text] [Related]
18. High resolution dual detector volume-of-interest cone beam breast CT--Demonstration with a bench top system. Shen Y; Yi Y; Zhong Y; Lai CJ; Liu X; You Z; Ge S; Wang T; Shaw CC Med Phys; 2011 Dec; 38(12):6429-42. PubMed ID: 22149826 [TBL] [Abstract][Full Text] [Related]
19. Slow gantry rotation acquisition technique for on-board four-dimensional digital tomosynthesis. Maurer J; Pan T; Yin FF Med Phys; 2010 Feb; 37(2):921-33. PubMed ID: 20229901 [TBL] [Abstract][Full Text] [Related]
20. Simulated scatter performance of an inverse-geometry dedicated breast CT system. Bhagtani R; Schmidt TG Med Phys; 2009 Mar; 36(3):788-96. PubMed ID: 19378739 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]