These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. A three-dimensional echocardiographic study on aortic-mitral coupling in transcatheter aortic valve replacement. Tsang W; Meineri M; Hahn RT; Veronesi F; Shah AP; Osten M; Nathan S; Russo M; Lang RM; Horlick EM Eur Heart J Cardiovasc Imaging; 2013 Oct; 14(10):950-6. PubMed ID: 23720379 [TBL] [Abstract][Full Text] [Related]
6. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. Jilaihawi H; Kashif M; Fontana G; Furugen A; Shiota T; Friede G; Makhija R; Doctor N; Leon MB; Makkar RR J Am Coll Cardiol; 2012 Apr; 59(14):1275-86. PubMed ID: 22365424 [TBL] [Abstract][Full Text] [Related]
7. Health Status After Transcatheter or Surgical Aortic Valve Replacement in Patients With Severe Aortic Stenosis at Increased Surgical Risk: Results From the CoreValve US Pivotal Trial. Arnold SV; Reynolds MR; Wang K; Magnuson EA; Baron SJ; Chinnakondepalli KM; Reardon MJ; Tadros PN; Zorn GL; Maini B; Mumtaz MA; Brown JM; Kipperman RM; Adams DH; Popma JJ; Cohen DJ; JACC Cardiovasc Interv; 2015 Aug; 8(9):1207-1217. PubMed ID: 26292584 [TBL] [Abstract][Full Text] [Related]
8. Impact of aortic valve replacement for aortic stenosis on dynamic mitral annular motion and geometry. Warraich HJ; Matyal R; Bergman R; Hess PE; Khabbaz K; Manning WJ; Mahmood F Am J Cardiol; 2013 Nov; 112(9):1445-9. PubMed ID: 23891429 [TBL] [Abstract][Full Text] [Related]
9. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement. Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778 [TBL] [Abstract][Full Text] [Related]
10. Imaging in patients with severe mitral annular calcification: insights from a multicentre experience using transatrial balloon-expandable valve replacement. Praz F; Khalique OK; Lee R; Wu IY; Russell H; Guerrero M; Wang DD; Veeragandham R; Islam AM; Deaton DW; Kaneko T; Eudailey KW; Akkoc D; Kantor A; Wang C; Tang DCH; Park JS; Leung D; Nazif TM; Vahl TP; Hahn RT; Kodali SK; Leon MB; Takayama H; Bapat V; Borger MA; George I Eur Heart J Cardiovasc Imaging; 2019 Dec; 20(12):1395-1406. PubMed ID: 31220240 [TBL] [Abstract][Full Text] [Related]
11. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. Willson AB; Webb JG; Labounty TM; Achenbach S; Moss R; Wheeler M; Thompson C; Min JK; Gurvitch R; Norgaard BL; Hague CJ; Toggweiler S; Binder R; Freeman M; Poulter R; Poulsen S; Wood DA; Leipsic J J Am Coll Cardiol; 2012 Apr; 59(14):1287-94. PubMed ID: 22365423 [TBL] [Abstract][Full Text] [Related]
12. Predicting paravalvular regurgitation following transcatheter valve replacement: utility of a novel method for three-dimensional echocardiographic measurements of the aortic annulus. Hahn RT; Khalique O; Williams MR; Koss E; Paradis JM; Daneault B; Kirtane AJ; George I; Leon MB; Kodali S J Am Soc Echocardiogr; 2013 Sep; 26(9):1043-52. PubMed ID: 23998695 [TBL] [Abstract][Full Text] [Related]
13. Transatrial implantation of a transcatheter heart valve for severe mitral annular calcification. Praz F; Khalique OK; Lee R; Veeragandham R; Russell H; Guerrero M; Islam AM; Deaton DW; Kaneko T; Kodali SK; Leon MB; Bapat V; Takayama H; Borger MA; George I J Thorac Cardiovasc Surg; 2018 Jul; 156(1):132-142. PubMed ID: 29627180 [TBL] [Abstract][Full Text] [Related]
14. Aortic and mitral valve replacement versus transcatheter aortic valve replacement in propensity-matched patients. McCarthy FH; Desai ND; Herrmann HC; Kobrin D; Vallabhajosyula P; Fox Z; Menon R; Augoustides JG; Giri JS; Anwaruddin S; Li RH; Jagasia DH; Bavaria JE; Szeto WY Ann Thorac Surg; 2014 Oct; 98(4):1267-73. PubMed ID: 25149054 [TBL] [Abstract][Full Text] [Related]
15. The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. Binder RK; Webb JG; Willson AB; Urena M; Hansson NC; Norgaard BL; Pibarot P; Barbanti M; Larose E; Freeman M; Dumont E; Thompson C; Wheeler M; Moss RR; Yang TH; Pasian S; Hague CJ; Nguyen G; Raju R; Toggweiler S; Min JK; Wood DA; Rodés-Cabau J; Leipsic J J Am Coll Cardiol; 2013 Jul; 62(5):431-8. PubMed ID: 23684679 [TBL] [Abstract][Full Text] [Related]
16. Combined mitro-aortic pathology: impact of previous aortic valve replacement upon outcomes of MitraClip therapy (from the German transcatheter mitral valve interventions registry). D'Ancona G; Kische S; Senges J; Ouarrak T; Puls M; Bekeredjian R; Sievert H; Safak E; Ortak J; Öner A; Schillinger W; Ince H EuroIntervention; 2017 Jul; 13(4):475-482. PubMed ID: 28394759 [TBL] [Abstract][Full Text] [Related]
17. A Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes. Tan JS; Leipsic J; Perlman G; Stub D; Dvir D; Hansson NC; Norgaard BL; Blanke P; Cheung A; Ye J; Thompson CR; Moss RR; Lauck S; Wood D; Webb J JACC Cardiovasc Interv; 2015 Nov; 8(13):1727-32. PubMed ID: 26476612 [TBL] [Abstract][Full Text] [Related]
18. Conventional surgery, sutureless valves, and transapical aortic valve replacement: what is the best option for patients with aortic valve stenosis? A multicenter, propensity-matched analysis. D'Onofrio A; Rizzoli G; Messina A; Alfieri O; Lorusso R; Salizzoni S; Glauber M; Di Bartolomeo R; Besola L; Rinaldi M; Troise G; Gerosa G J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1065-70; discussion 1070-1. PubMed ID: 24021955 [TBL] [Abstract][Full Text] [Related]
19. The Effect of Initiation of a Transcatheter Aortic Valve Replacement Program in the Treatment of Severe Aortic Stenosis. Ad N; Holmes SD; Shuman DJ; Rongione AJ; Massimiano PS; Speir AM; Pritchard G; Yazdani S; Raybuck BD Semin Thorac Cardiovasc Surg; 2016 Summer; 28(2):353-360. PubMed ID: 28043443 [TBL] [Abstract][Full Text] [Related]