These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 23255545)

  • 21. The energy margin strategy for reducing dose variation due to setup uncertainty in intensity modulated proton therapy (IMPT) delivered with distal edge tracking (DET).
    Zhang M; Flynn RT; Mo X; Mackie TR
    J Appl Clin Med Phys; 2012 Sep; 13(5):3863. PubMed ID: 22955652
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Prediction of output factor, range, and spread-out bragg peak for proton therapy.
    Kim DW; Lim YK; Ahn SH; Shin J; Shin D; Yoon M; Lee SB; Kim DY; Park SY
    Med Dosim; 2011; 36(2):145-52. PubMed ID: 20599372
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparing photon and proton-based hypofractioned SBRT for prostate cancer accounting for robustness and realistic treatment deliverability.
    Goddard LC; Brodin NP; Bodner WR; Garg MK; Tomé WA
    Br J Radiol; 2018 May; 91(1085):20180010. PubMed ID: 29436852
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dose-shaping using targeted sparse optimization.
    Sayre GA; Ruan D
    Med Phys; 2013 Jul; 40(7):071711. PubMed ID: 23822415
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Benchmarking of a treatment planning system for spot scanning proton therapy: comparison and analysis of robustness to setup errors of photon IMRT and proton SFUD treatment plans of base of skull meningioma.
    Harding R; Trnková P; Weston SJ; Lilley J; Thompson CM; Short SC; Loughrey C; Cosgrove VP; Lomax AJ; Thwaites DI
    Med Phys; 2014 Nov; 41(11):111710. PubMed ID: 25370624
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Adaptive method for multicriteria optimization of intensity-modulated proton therapy.
    Kamal-Sayed H; Ma J; Tseung H; Abdel-Rehim A; Herman MG; Beltran CJ
    Med Phys; 2018 Dec; 45(12):5643-5652. PubMed ID: 30332515
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.
    Liu C; Schild SE; Chang JY; Liao Z; Korte S; Shen J; Ding X; Hu Y; Kang Y; Keole SR; Sio TT; Wong WW; Sahoo N; Bues M; Liu W
    Int J Radiat Oncol Biol Phys; 2018 Jun; 101(2):479-489. PubMed ID: 29550033
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Superiority in Robustness of Multifield Optimization Over Single-Field Optimization for Pencil-Beam Proton Therapy for Oropharynx Carcinoma: An Enhanced Robustness Analysis.
    Stützer K; Lin A; Kirk M; Lin L
    Int J Radiat Oncol Biol Phys; 2017 Nov; 99(3):738-749. PubMed ID: 29280468
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning.
    Unkelbach J; Bortfeld T; Martin BC; Soukup M
    Med Phys; 2009 Jan; 36(1):149-63. PubMed ID: 19235384
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases.
    Tran A; Zhang J; Woods K; Yu V; Nguyen D; Gustafson G; Rosen L; Sheng K
    Radiat Oncol; 2017 Jan; 12(1):10. PubMed ID: 28077128
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Proton therapy in the clinic.
    DeLaney TF
    Front Radiat Ther Oncol; 2011; 43():465-485. PubMed ID: 21625169
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Including robustness in multi-criteria optimization for intensity-modulated proton therapy.
    Chen W; Unkelbach J; Trofimov A; Madden T; Kooy H; Bortfeld T; Craft D
    Phys Med Biol; 2012 Feb; 57(3):591-608. PubMed ID: 22222720
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Uncertainty incorporated beam angle optimization for IMPT treatment planning.
    Cao W; Lim GJ; Lee A; Li Y; Liu W; Ronald Zhu X; Zhang X
    Med Phys; 2012 Aug; 39(8):5248-56. PubMed ID: 22894449
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.
    Liu W; Schild SE; Chang JY; Liao Z; Chang YH; Wen Z; Shen J; Stoker JB; Ding X; Hu Y; Sahoo N; Herman MG; Vargas C; Keole S; Wong W; Bues M
    Int J Radiat Oncol Biol Phys; 2016 May; 95(1):523-533. PubMed ID: 26725727
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Robust intensity-modulated proton therapy to reduce high linear energy transfer in organs at risk.
    An Y; Shan J; Patel SH; Wong W; Schild SE; Ding X; Bues M; Liu W
    Med Phys; 2017 Dec; 44(12):6138-6147. PubMed ID: 28976574
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical implementation in proton therapy of multi-field optimization by a hybrid method combining conventional PTV with robust optimization.
    Tommasino F; Widesott L; Fracchiolla F; Lorentini S; Righetto R; Algranati C; Scifoni E; Dionisi F; Scartoni D; Amelio D; Cianchetti M; Schwarz M; Amichetti M; Farace P
    Phys Med Biol; 2020 Feb; 65(4):045002. PubMed ID: 31851957
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Robust optimization in intensity-modulated proton therapy to account for anatomy changes in lung cancer patients.
    Li H; Zhang X; Park P; Liu W; Chang J; Liao Z; Frank S; Li Y; Poenisch F; Mohan R; Gillin M; Zhu R
    Radiother Oncol; 2015 Mar; 114(3):367-72. PubMed ID: 25708992
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of OAR dose sparing and plan robustness of beam-specific PTV in lung cancer IMRT treatment.
    Chang Y; Xiao F; Quan H; Yang Z
    Radiat Oncol; 2020 Oct; 15(1):241. PubMed ID: 33069253
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intensity modulated radiation therapy using laser-accelerated protons: a Monte Carlo dosimetric study.
    Fourkal E; Li JS; Xiong W; Nahum A; Ma CM
    Phys Med Biol; 2003 Dec; 48(24):3977-4000. PubMed ID: 14727747
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dosimetric advantages of IMPT over IMRT for laser-accelerated proton beams.
    Luo W; Li J; Fourkal E; Fan J; Xu X; Chen Z; Jin L; Price R; Ma CM
    Phys Med Biol; 2008 Dec; 53(24):7151-66. PubMed ID: 19033641
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.