BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 23257169)

  • 1. Influence of phantom thickness and material on the backscatter factors for diagnostic x-ray beam dosimetry.
    Benmakhlouf H; Fransson A; Andreo P
    Phys Med Biol; 2013 Jan; 58(2):247-60. PubMed ID: 23257169
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements.
    Kim J; Hill R; Claridge Mackonis E; Kuncic Z
    Phys Med Biol; 2010 Feb; 55(3):783-97. PubMed ID: 20071763
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.
    Chow JC; Jiang R
    Phys Med Biol; 2012 Jun; 57(12):3885-99. PubMed ID: 22642985
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Backscatter factors and mass energy-absorption coefficient ratios for diagnostic radiology dosimetry.
    Benmakhlouf H; Bouchard H; Fransson A; Andreo P
    Phys Med Biol; 2011 Nov; 56(22):7179-204. PubMed ID: 22024474
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The water equivalence of solid phantoms for low energy photon beams.
    Hill R; Kuncic Z; Baldock C
    Med Phys; 2010 Aug; 37(8):4355-63. PubMed ID: 20879595
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variations in backscatter observed in PMMA whole-body dosimetry slab phantoms.
    Schwahn SO; Gesell TF
    Radiat Prot Dosimetry; 2008; 128(3):375-81. PubMed ID: 17848386
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
    DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
    Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of correction factors for a 2D diode array device in MV photon beams.
    Zhou X; Both S; Zhu TC
    Med Phys; 2009 Feb; 36(2):523-9. PubMed ID: 19291991
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams.
    Araki F
    Phys Med Biol; 2012 Nov; 57(22):7615-27. PubMed ID: 23103477
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fluence correction factors and stopping power ratios for clinical ion beams.
    Lühr A; Hansen DC; Sobolevsky N; Palmans H; Rossomme S; Bassler N
    Acta Oncol; 2011 Aug; 50(6):797-805. PubMed ID: 21767177
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Backscatter correction factor for megavoltage photon beam.
    Hu Y; Zhu TC
    Med Phys; 2011 Oct; 38(10):5563-8. PubMed ID: 21992374
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo assessment of CT dose equilibration in PMMA and water cylinders with diameters from 6 to 55 cm.
    Li X; Zhang D; Liu B
    Med Phys; 2013 Mar; 40(3):031903. PubMed ID: 23464318
    [TBL] [Abstract][Full Text] [Related]  

  • 13. New weighting factor of weighted CTDI equation for PMMA phantom diameter from 8 to 40 cm: A Monte Carlo study.
    Haba T; Koyama S; Kinomura Y; Ida Y; Kobayashi M
    Med Phys; 2017 Dec; 44(12):6603-6609. PubMed ID: 28960375
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulated and measured dose response characteristics of detectors used for CT dosimetry.
    Hakanen A
    Phys Med Biol; 2012 Aug; 57(16):N319-28. PubMed ID: 22850226
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mammography dosimetry using an in-house developed polymethyl methacrylate phantom.
    Sharma R; Sharma SD; Mayya YS; Chourasiya G
    Radiat Prot Dosimetry; 2012 Aug; 151(2):379-85. PubMed ID: 22232773
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of in-air output ratios using different miniphantom materials.
    Li J; Zhu TC
    Phys Med Biol; 2006 Aug; 51(15):3819-34. PubMed ID: 16861783
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calculation of backscatter factors for diagnostic radiology using Monte Carlo methods.
    Petoussi-Henss N; Zankl M; Drexler G; Panzer W; Regulla D
    Phys Med Biol; 1998 Aug; 43(8):2237-50. PubMed ID: 9725601
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries.
    Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M
    Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms.
    Li X; Zhang D; Liu B
    Med Phys; 2013 Aug; 40(8):081914. PubMed ID: 23927328
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams.
    Hill R; Holloway L; Baldock C
    Phys Med Biol; 2005 Nov; 50(21):N331-44. PubMed ID: 16237233
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.