These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
173 related articles for article (PubMed ID: 23257388)
1. Qualitative and quantitative assessment of stent restenosis by optical coherence tomography: comparison between drug-eluting and bare-metal stents. Nagoshi R; Shinke T; Otake H; Shite J; Matsumoto D; Kawamori H; Nakagawa M; Kozuki A; Hariki H; Inoue T; Ohsue T; Taniguchi Y; Iwasaki M; Nishio R; Hiranuma N; Konishi A; Kinutani H; Miyoshi N; Takaya T; Yamada S; Yasaka Y; Hayashi T; Yokoyama M; Kato H; Kadotani M; Ohnishi Y; Hirata K Circ J; 2013; 77(3):652-60. PubMed ID: 23257388 [TBL] [Abstract][Full Text] [Related]
2. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up. Poerner TC; Otto S; Gassdorf J; Nitsche K; Janiak F; Scheller B; Goebel B; Jung C; Figulla HR Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536 [TBL] [Abstract][Full Text] [Related]
3. Differences in tissue characterization of restenotic neointima between sirolimus-eluting stent and bare-metal stent: integrated backscatter intravascular ultrasound analysis for in-stent restenosis. Ando H; Amano T; Takashima H; Harada K; Kitagawa K; Suzuki A; Kunimura A; Shimbo Y; Harada K; Yoshida T; Kato B; Uetani T; Kato M; Matsubara T; Kumagai S; Yoshikawa D; Isobe S; Ishii H; Murohara T Eur Heart J Cardiovasc Imaging; 2013 Oct; 14(10):996-1001. PubMed ID: 23341147 [TBL] [Abstract][Full Text] [Related]
4. Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation. Tada T; Kadota K; Hosogi S; Miyake K; Ohya M; Amano H; Izawa Y; Kanazawa T; Kubo S; Ichinohe T; Hyoudou Y; Hayakawa Y; Sabbah MM; Otsuru S; Hasegawa D; Habara S; Tanaka H; Fuku Y; Katoh H; Goto T; Mitsudo K Eur Heart J Cardiovasc Imaging; 2015 Oct; 16(10):1101-11. PubMed ID: 25762559 [TBL] [Abstract][Full Text] [Related]
5. Neointimal patterns obtained by optical coherence tomography correlate with specific histological components and neointimal proliferation in a swine model of restenosis. Kim JS; Afari ME; Ha J; Tellez A; Milewski K; Conditt G; Cheng Y; Hua Yi G; Kaluza GL; Granada JF Eur Heart J Cardiovasc Imaging; 2014 Mar; 15(3):292-8. PubMed ID: 24022066 [TBL] [Abstract][Full Text] [Related]
6. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study. Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717 [TBL] [Abstract][Full Text] [Related]
7. Impact of neointimal tissue characterization and heterogeneity of bare-metal stents and drug-eluting stents on the time course after stent implantation evaluated by integrated backscatter intravascular ultrasound. Yoshizane T; Tanaka S; Abe S; Ueno T; Goto Y; Kojima T; Iwama M; Arai M; Noda T; Kawasaki M Heart Vessels; 2019 Oct; 34(10):1639-1649. PubMed ID: 30997558 [TBL] [Abstract][Full Text] [Related]
8. Paclitaxcel-coated balloon plus bare metal stent vs. sirolimus-eluting stent in de novo lesions: an IVUS study. Fischer D; Scheller B; Schäfer A; Klein G; Böhm M; Clever Y; Cremers B EuroIntervention; 2012 Aug; 8(4):450-5. PubMed ID: 22917728 [TBL] [Abstract][Full Text] [Related]
9. In-stent restenosis assessed with frequency domain optical coherence tomography shows smooth coronary arterial healing process in second-generation drug-eluting stents. Kajiya T; Yamaguchi H; Takaoka J; Fukunaga K; Arima R; Miyamura A; Ninomiya T; Atsuchi N; Atsuchi Y; Terashima M; Kaneda H; Ohishi M Singapore Med J; 2019 Jan; 60(1):48-51. PubMed ID: 29632955 [TBL] [Abstract][Full Text] [Related]
10. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents. Guagliumi G; Musumeci G; Sirbu V; Bezerra HG; Suzuki N; Fiocca L; Matiashvili A; Lortkipanidze N; Trivisonno A; Valsecchi O; Biondi-Zoccai G; Costa MA; JACC Cardiovasc Interv; 2010 May; 3(5):531-9. PubMed ID: 20488410 [TBL] [Abstract][Full Text] [Related]
11. Differences in optical coherence tomographic findings and clinical outcomes between excimer laser and cutting balloon angioplasty for focal in-stent restenosis lesions. Nishino M; Lee Y; Nakamura D; Yoshimura T; Taniike M; Makino N; Kato H; Egami Y; Shutta R; Tanouchi J; Yamada Y J Invasive Cardiol; 2012 Oct; 24(10):478-83. PubMed ID: 23043029 [TBL] [Abstract][Full Text] [Related]
12. Influence of a paclitaxel coated balloon in combination with a bare metal stent on restenosis and endothelial function: comparison with a drug eluting stent and a bare metal stent. Clever YP; Cremers B; Speck U; Dietz U; Böhm M; Scheller B Catheter Cardiovasc Interv; 2014 Aug; 84(2):323-31. PubMed ID: 23996969 [TBL] [Abstract][Full Text] [Related]
13. Simple balloon dilation for drug-eluting in-stent restenosis: an optical coherent tomography analysis. Arikawa R; Yamaguchi H; Takaoka J; Miyamura A; Atsuchi N; Ninomiya T; Atsuchi Y; Ohishi M; Terashima M; Kaneda H Cardiovasc Revasc Med; 2015; 16(1):27-31. PubMed ID: 25578507 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of neointimal morphology of lesions with or without in-stent restenosis: an optical coherence tomography study. Lee SJ; Kim BK; Kim JS; Ko YG; Choi D; Jang Y; Hong MK Clin Cardiol; 2011 Oct; 34(10):633-9. PubMed ID: 21928365 [TBL] [Abstract][Full Text] [Related]
15. The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography. Sato K; Costopoulos C; Takebayashi H; Naganuma T; Miyazaki T; Goto K; Yamane H; Hagikura A; Kikuta Y; Taniguchi M; Hiramatsu S; Ito H; Colombo A; Haruta S J Cardiol; 2014 Dec; 64(6):488-95. PubMed ID: 24794757 [TBL] [Abstract][Full Text] [Related]
16. Elutax paclitaxel-eluting balloon followed by bare-metal stent compared with Xience V drug-eluting stent in the treatment of de novo coronary stenosis: a randomized trial. Liistro F; Porto I; Angioli P; Grotti S; Ducci K; Falsini G; Bolognese L Am Heart J; 2013 Nov; 166(5):920-6. PubMed ID: 24176449 [TBL] [Abstract][Full Text] [Related]
17. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods. Poerner TC; Otto S; Gassdorf J; Janiak F; Danzer C; Ferrari M; Figulla HR EuroIntervention; 2011 May; 7 Suppl K():K93-9. PubMed ID: 22027737 [TBL] [Abstract][Full Text] [Related]
18. Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinical trial. Adriaenssens T; Dens J; Ughi G; Bennett J; Dubois C; Sinnaeve P; Wiyono S; Coosemans M; Belmans A; D'hooge J; Vrolix M; Desmet W EuroIntervention; 2014 Aug; 10(4):439-48. PubMed ID: 25138182 [TBL] [Abstract][Full Text] [Related]
19. Association between tissue characteristics evaluated with optical coherence tomography and mid-term results after paclitaxel-coated balloon dilatation for in-stent restenosis lesions: a comparison with plain old balloon angioplasty. Tada T; Kadota K; Hosogi S; Miyake K; Amano H; Nakamura M; Izawa Y; Kubo S; Ichinohe T; Hyoudou Y; Eguchi H; Hayakawa Y; Otsuru S; Hasegawa D; Shigemoto Y; Habara S; Tanaka H; Fuku Y; Kato H; Goto T; Mitsudo K Eur Heart J Cardiovasc Imaging; 2014 Mar; 15(3):307-15. PubMed ID: 24042176 [TBL] [Abstract][Full Text] [Related]
20. A randomized comparison of drug-eluting balloon versus everolimus-eluting stent in patients with bare-metal stent-in-stent restenosis: the RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: paclitaxel-eluting balloon vs. everolimus-eluting stent). Alfonso F; Pérez-Vizcayno MJ; Cárdenas A; García Del Blanco B; Seidelberger B; Iñiguez A; Gómez-Recio M; Masotti M; Velázquez MT; Sanchís J; García-Touchard A; Zueco J; Bethencourt A; Melgares R; Cequier A; Dominguez A; Mainar V; López-Mínguez JR; Moreu J; Martí V; Moreno R; Jiménez-Quevedo P; Gonzalo N; Fernández C; Macaya C; J Am Coll Cardiol; 2014 Apr; 63(14):1378-86. PubMed ID: 24412457 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]