These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 2326507)

  • 1. [Leakage radiations in a medical electron accelerator facility--calculation of neutron doses in the facility].
    Ishimatsu K; Morikawa K
    Radioisotopes; 1990 Feb; 39(2):29-36. PubMed ID: 2326507
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Leakage radiations in a medical electron accelerator facility--measurement of neutrons and comparison with calculation].
    Morikawa K; Ishimatsu K
    Radioisotopes; 1990 Feb; 39(2):37-44. PubMed ID: 2326508
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Shielding design and detection of neutrons from medical and industrial electron accelerators--simple method of design calculation for neutron shielding].
    Nakamura T; Uwamino Y
    Radioisotopes; 1986 Feb; 35(2):51-6. PubMed ID: 3704202
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
    Falcão RC; Facure A; Silva AX
    Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities.
    Kim HS; Jang KW; Park YH; Kwon JW; Choi HS; Lee JK; Kim JK
    Med Phys; 2009 May; 36(5):1512-20. PubMed ID: 19544767
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the photoneutron field produced in a medical linear accelerator.
    Kim HS; Park YH; Koo BC; Kwon JW; Lee JS; Choi HS
    Radiat Prot Dosimetry; 2007; 123(3):323-8. PubMed ID: 17077093
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Be aware of neutrons outside short mazes from 10-MV linear accelerators X-rays in radiotherapy facilities.
    Brockstedt S; Holstein H; Jakobsson L; Tomaszewicz A; Knöös T
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):464-7. PubMed ID: 25802465
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement and calculation of neutron leakage from a medical electron accelerator.
    Uwamino Y; Nakamura T; Ohkubo T; Hara A
    Med Phys; 1986; 13(3):374-84. PubMed ID: 3088411
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of neutron dose equivalent levels at the maze entrance of medical accelerator treatment rooms.
    McGinley PH; Butker EK
    Med Phys; 1991; 18(2):279-81. PubMed ID: 2046615
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Shielding design and detection of neutrons from medical and industrial electron accelerators--accuracy evaluation of simple calculation method by neutron measurement].
    Nakamura T
    Radioisotopes; 1986 Feb; 35(2):57-64. PubMed ID: 3704203
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neutron contamination of 10 MV X-rays: its relevance to treatment room door and maze design.
    Rudd PJ; Prior D; Austin-Smith S
    Br J Radiol; 2007 Jun; 80(954):469-75. PubMed ID: 17360932
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
    Wang X; Esquivel C; Nes E; Shi C; Papanikolaou N; Charlton M
    Med Phys; 2011 Mar; 38(3):1141-9. PubMed ID: 21520826
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Leakage radiations in a medical electron accelerator facility--X-rays and capture gamma-rays].
    Morikawa K; Ishimatsu K
    Radioisotopes; 1990 Mar; 39(3):83-90. PubMed ID: 2336473
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of neutron-moderating materials in high-energy linear accelerator mazes.
    Lalonde R
    Phys Med Biol; 1997 Feb; 42(2):335-44. PubMed ID: 9044416
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A method for calculating the dose due to capture gamma rays in accelerator mazes.
    McGinley PH; Miner MS; Mitchum ML
    Phys Med Biol; 1995 Sep; 40(9):1467-73. PubMed ID: 8532759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of neutron dose in the maze of medical electron accelerators.
    Carinou E; Kamenopoulou V; Stamatelatos IE
    Med Phys; 1999 Dec; 26(12):2520-5. PubMed ID: 10619233
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies.
    Jaradat AK; Biggs PJ
    Med Phys; 2008 May; 35(5):1711-7. PubMed ID: 18561646
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator.
    Krmar M; Nikolić D; Kuzmanović A; Kuzmanović Z; Ganezer K
    Med Phys; 2013 Aug; 40(8):083902. PubMed ID: 23927362
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The neutron dose and energy spectrum outside a 20-MV accelerator treatment room.
    Muller-Runkel R; Ovadia J; Culbert H; Cooke RH; Dolecek EH
    Med Phys; 1986; 13(5):742-7. PubMed ID: 3097465
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
    Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
    Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.