BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

288 related articles for article (PubMed ID: 23267457)

  • 1. Progressive migration of broken Kirschner wire into the proximal tibia following tension-band wiring technique of a patellar fracture--case report.
    Konda SR; Dayan A; Egol KA
    Bull NYU Hosp Jt Dis; 2012; 70(4):279-82. PubMed ID: 23267457
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Delayed migration of K-wire into popliteal fossa used for tension band wiring of patellar fracture.
    Meena S; Nag HL; Kumar S; Barwar N; Mittal S; Singla A
    Chin J Traumatol; 2013; 16(3):186-8. PubMed ID: 23735556
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Migration to the popliteal fossa of broken wires from a fixed patellar fracture.
    Choi HR; Min KD; Choi SW; Lee BI
    Knee; 2008 Dec; 15(6):491-3. PubMed ID: 18752955
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report.
    Aydın E; Dülgeroğlu TC; Metineren H
    J Med Case Rep; 2016 Feb; 10():41. PubMed ID: 26911242
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The intra-articular migration of the broken wire: a rare complication of circumferential wiring in patellar fractures.
    Chen YJ; Wu CC; Hsu RW; Shih CH
    Changgeng Yi Xue Za Zhi; 1994 Sep; 17(3):276-9. PubMed ID: 7954008
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.
    Hsu KL; Chang WL; Yang CY; Yeh ML; Chang CW
    Injury; 2017 Dec; 48(12):2800-2806. PubMed ID: 29037518
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Locking knee after intra-articular migration of broken patella tension band wire: an extraordinary intra-articular migration via pseudarthrosis line.
    Wang L; Lee KT
    Acta Orthop Traumatol Turc; 2013; 47(6):444-7. PubMed ID: 24509227
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Self locking tension band technique in transverse patellar fractures.
    Us AK; Kinik H
    Int Orthop; 1996; 20(6):357-8. PubMed ID: 9049763
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.
    Hoshino CM; Tran W; Tiberi JV; Black MH; Li BH; Gold SM; Navarro RA
    J Bone Joint Surg Am; 2013 Apr; 95(7):653-9. PubMed ID: 23553301
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Complications Related to Implant Fixation of Patellar Fractures: Comparison of Ring Pins versus Bent K-Wires.
    Kyung MG; Lee SH; Kim MB
    J Knee Surg; 2017 Jul; 30(6):560-564. PubMed ID: 27776370
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Treatment of displaced fractures of the patella: Tension band wiring technique with the one-end or both-ends K-wire bending fixation method.
    Huang PH; Hsu CH; Hsu SL; Liu HC
    J Orthop Surg (Hong Kong); 2021; 29(1):2309499020988179. PubMed ID: 33550932
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].
    Zhang J; Jiang XY; Huang XW
    Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Jun; 48(3):534-8. PubMed ID: 27318920
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Patella fracture fixation with suture and wire: you reap what you sew.
    Egol K; Howard D; Monroy A; Crespo A; Tejwani N; Davidovitch R
    Iowa Orthop J; 2014; 34():63-7. PubMed ID: 25328461
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Treatment results of fractures of the patella using pre-patellar tension wiring. Analysis of a series of 203 cases].
    Mehdi M; Husson JL; Polard JL; Ouahmed A; Poncer R; Lombard J
    Acta Orthop Belg; 1999 Jun; 65(2):188-96. PubMed ID: 10427801
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures.
    Lee SK; Hwang YS; Choy WS
    Orthopedics; 2014 Mar; 37(3):e265-71. PubMed ID: 24762154
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Complications of Kirschner Wire Use in Open Reduction and Internal Fixation of Calcaneal Fractures.
    Dorr MC; Backes M; Luitse JS; de Jong VM; Schepers T
    J Foot Ankle Surg; 2016; 55(5):915-7. PubMed ID: 27405782
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation.
    Yang TY; Huang TW; Chuang PY; Huang KC
    BMC Musculoskelet Disord; 2018 May; 19(1):167. PubMed ID: 29793461
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tibial nerve injury associated with broken wire migration following tension band wiring of patella fracture.
    Jirangkul P; Kunsuwan P; Lorsuwannarat N
    J Orthop Sci; 2023 Nov; 28(6):1566-1569. PubMed ID: 34801342
    [No Abstract]   [Full Text] [Related]  

  • 20. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.