BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

286 related articles for article (PubMed ID: 23267457)

  • 21. Comparison of the Therapeutic Effects of Tension Band with Cannulated Screw and Tension Band with Kirschner Wire on Patella Fracture.
    Liu C; Ren H; Wan C; Ma J
    Comput Math Methods Med; 2020; 2020():4065978. PubMed ID: 32908578
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Patellar tension band wiring: a revised technique.
    Wu CC; Tai CL; Chen WJ
    Arch Orthop Trauma Surg; 2001; 121(1-2):12-6. PubMed ID: 11195111
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical Analysis of the Kirschner-Wire Depth of the Modified Tension Band Wiring Technique in Transverse Patellar Fractures: An Experimental Study Using the Finite-Element Method.
    Kim Y; Kwon M; Ryu JY; Moon SW
    Clin Orthop Surg; 2021 Sep; 13(3):315-319. PubMed ID: 34484623
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Transthoracic migration of a Kirschner wire from the humerus to the abdomen.
    Julià D; Baldó X; Gómez N; Mármol E
    Eur J Cardiothorac Surg; 2012 May; 41(5):1197-8. PubMed ID: 22219432
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The chopstick-noodle twist: an easy technique of percutaneous patellar fixation in minimally displaced patellar fractures.
    Muzaffar N; Ahmad N; Ahmad A; Ahmad N
    Trop Doct; 2012 Jan; 42(1):25-7. PubMed ID: 22290109
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Displaced patella fractures.
    Della Rocca GJ
    J Knee Surg; 2013 Oct; 26(5):293-9. PubMed ID: 23966286
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Modified tension band wiring of patellar fracture as a technique to minimize postoperative complications: A case report.
    Yu T; Wu Z; Mohamed SO; Ju W; Liu X; Qi B
    Medicine (Baltimore); 2020 Mar; 99(12):e19576. PubMed ID: 32195969
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Complications of tension-band wiring of olecranon fractures.
    Macko D; Szabo RM
    J Bone Joint Surg Am; 1985 Dec; 67(9):1396-401. PubMed ID: 3908460
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Modified Tension Band Wiring Using FiberWire for Patellar Fractures.
    Lee BJ; Chon J; Yoon JY; Jung D
    Clin Orthop Surg; 2019 Jun; 11(2):244-248. PubMed ID: 31156779
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transmediastinal migration of Kirschner wire.
    Marchi E; Reis MP; Carvalho MV
    Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):869-70. PubMed ID: 18658165
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mid-term (2-8 years) follow-up of open reduction and internal fixation of patella fractures: does the surgical technique influence the outcome?
    Eggink KM; Jaarsma RL
    Arch Orthop Trauma Surg; 2011 Mar; 131(3):399-404. PubMed ID: 21161252
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [TREATMENT OF PATELLAR FRACTURES USING Kirschner WITH HOLE AND TENSION BAND SYSTEM WITH WIRE WINDING AND PRESSURE].
    Li C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Dec; 29(12):1466-8. PubMed ID: 27044211
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Forgotten Kirschner wire passing across the sigmoid colon.
    Matsumoto H; Yo S; Fukushima S; Osawa M; Murao T; Ishii M; Fujita M; Shiotani A
    Clin J Gastroenterol; 2017 Apr; 10(2):154-156. PubMed ID: 28110444
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Where should Kirschner wires be placed when fixing patella fracture with modified tension-band wiring? A finite element analysis.
    Ling M; Zhan S; Jiang D; Hu H; Zhang C
    J Orthop Surg Res; 2019 Jan; 14(1):14. PubMed ID: 30634995
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Management of displaced comminuted patellar fracture with titanium cable cerclage.
    Yang L; Yueping O; Wen Y
    Knee; 2010 Aug; 17(4):283-6. PubMed ID: 20223675
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire.
    Chang CW; Chen YN; Li CT; Chung YH; Chang CH; Peng YT
    J Orthop Surg (Hong Kong); 2018; 26(3):2309499018789705. PubMed ID: 30037293
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A comparison of EFECE systems with tension band wiring for patella fracture fixation in cadavers.
    Karadeniz E; Keskinoz EN
    J Orthop Surg Res; 2020 Jul; 15(1):256. PubMed ID: 32650813
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparative study of knee function after patellectomy and osteosynthesis with a tension band wire following patellar fractures.
    Marya SK; Bhan S; Dave PK
    Int Surg; 1987; 72(4):211-3. PubMed ID: 3448031
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The migration of a broken luque rod: a case report.
    Hirano K; Deguchi M; Kanamono T
    J Spinal Disord Tech; 2007 Apr; 20(2):176-9. PubMed ID: 17414990
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Roles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation.
    Chen CH; Chen YN; Li CT; Chang CW; Chang CH; Peng YT
    BMC Musculoskelet Disord; 2019 Mar; 20(1):99. PubMed ID: 30832645
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.