139 related articles for article (PubMed ID: 23269092)
1. Clinical validity of cerebral oxygen saturation measured by time-resolved spectroscopy during carotid endarterectomy.
Yoshitani K; Kuwajima K; Irie T; Inatomi Y; Miyazaki A; Iihara K; Ohnishi Y
J Neurosurg Anesthesiol; 2013 Jul; 25(3):248-53. PubMed ID: 23269092
[TBL] [Abstract][Full Text] [Related]
2. [Cerebral oximetry by infrared spectroscopy in comparison with continuous measurement of oxygen saturation of the jugular vein bulb in interventions of the internal carotid artery].
Schindler E; Zickmann B; Müller M; Boldt J; Kroll J; Hempelmann G
Vasa; 1995; 24(2):168-75. PubMed ID: 7793150
[TBL] [Abstract][Full Text] [Related]
3. Continuous monitoring of jugular bulb venous oxygen saturation for evaluation of cerebral perfusion during carotid endarterectomy.
Niinai H; Nakagawa I; Shima T; Kawamoto M; Yuge O
Hiroshima J Med Sci; 1998 Dec; 47(4):133-7. PubMed ID: 9973738
[TBL] [Abstract][Full Text] [Related]
4. An assessment of contributions made by extracranial tissues during cerebral oximetry.
Samra SK; Stanley JC; Zelenock GB; Dorje P
J Neurosurg Anesthesiol; 1999 Jan; 11(1):1-5. PubMed ID: 9890378
[TBL] [Abstract][Full Text] [Related]
5. Arterial and venous contributions to near-infrared cerebral oximetry.
Watzman HM; Kurth CD; Montenegro LM; Rome J; Steven JM; Nicolson SC
Anesthesiology; 2000 Oct; 93(4):947-53. PubMed ID: 11020744
[TBL] [Abstract][Full Text] [Related]
6. Cutaneous vasoconstriction affects near-infrared spectroscopy determined cerebral oxygen saturation during administration of norepinephrine.
Sørensen H; Secher NH; Siebenmann C; Nielsen HB; Kohl-Bareis M; Lundby C; Rasmussen P
Anesthesiology; 2012 Aug; 117(2):263-70. PubMed ID: 22739762
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous measurement of cerebral hemoglobin oxygen saturation and blood volume in asphyxiated neonates by near-infrared time-resolved spectroscopy.
Nakamura S; Koyano K; Jinnai W; Hamano S; Yasuda S; Konishi Y; Kuboi T; Kanenishi K; Nishida T; Kusaka T
Brain Dev; 2015 Nov; 37(10):925-32. PubMed ID: 25975705
[TBL] [Abstract][Full Text] [Related]
8. Early post-ischemic hyperemia on transcranial cerebral oxygen saturation monitoring in carotid endarterectomy is associated with severity of cerebral ischemic insult during carotid artery clamping.
Kobayashi M; Ogasawara K; Suga Y; Chida K; Yoshida K; Otawara Y; Tsushima E; Ogawa A
Neurol Res; 2009 Sep; 31(7):728-33. PubMed ID: 19108754
[TBL] [Abstract][Full Text] [Related]
9. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy.
Pennekamp CW; Immink RV; den Ruijter HM; Kappelle LJ; Bots ML; Buhre WF; Moll FL; de Borst GJ
Eur J Vasc Endovasc Surg; 2013 Oct; 46(4):397-403. PubMed ID: 23973277
[TBL] [Abstract][Full Text] [Related]
10. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy.
Rigamonti A; Scandroglio M; Minicucci F; Magrin S; Carozzo A; Casati A
J Clin Anesth; 2005 Sep; 17(6):426-30. PubMed ID: 16171662
[TBL] [Abstract][Full Text] [Related]
11. Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia.
Samra SK; Dorje P; Zelenock GB; Stanley JC
Stroke; 1996 Jan; 27(1):49-55. PubMed ID: 8553402
[TBL] [Abstract][Full Text] [Related]
12. Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgery.
Ali MS; Harmer M; Vaughan RS; Dunne JA; Latto IP
Can J Anaesth; 2001 May; 48(5):497-501. PubMed ID: 11394522
[TBL] [Abstract][Full Text] [Related]
13. Correlation between cerebral oxygen saturation measured by near-infrared spectroscopy and jugular oxygen saturation in patients with severe closed head injury.
Ter Minassian A; Poirier N; Pierrot M; Menei P; Granry JC; Ursino M; Beydon L
Anesthesiology; 1999 Oct; 91(4):985-90. PubMed ID: 10519501
[TBL] [Abstract][Full Text] [Related]
14. Neurologic Derangement and Regional Cerebral Oxygen Desaturation Associated With Patency of the Circle of Willis During Carotid Endarterectomy.
Choi BM; Park SK; Shin S; Cho YP; Kwon TW; Choi YJ; Lee EK; Noh GJ
J Cardiothorac Vasc Anesth; 2015 Oct; 29(5):1200-5. PubMed ID: 26384627
[TBL] [Abstract][Full Text] [Related]
15. [Relationship between regional cerebrovascular oxygen saturation and jugular bulb oxygen saturation during carotid endarterectomy].
Kubo T; Nakagawa I; Hidaka S; Uesugi F; Hamaguchi K; Kato T
Masui; 2005 Oct; 54(10):1104-8. PubMed ID: 16231762
[TBL] [Abstract][Full Text] [Related]
16. Cerebral oximetry during carotid clamping: is blood pressure raising necessary?
Giustiniano E; Alfano A; Battistini GM; Gavazzeni V; Spoto MR; Cancellieri F
J Cardiovasc Med (Hagerstown); 2010 Jul; 11(7):522-8. PubMed ID: 20527713
[TBL] [Abstract][Full Text] [Related]
17. Cerebral oxygen saturation measured by near-infrared spectroscopy and jugular venous bulb oxygen saturation during arthroscopic shoulder surgery in beach chair position under sevoflurane-nitrous oxide or propofol-remifentanil anesthesia.
Jeong H; Jeong S; Lim HJ; Lee J; Yoo KY
Anesthesiology; 2012 May; 116(5):1047-56. PubMed ID: 22421420
[TBL] [Abstract][Full Text] [Related]
18. Hemodynamics and jugular venous oxygen saturation during carotid endarterectomy: a comparison between general and locoregional anesthesia.
Dias NV; Kölbel T; Gonçalves I; Chew M; Wistrand J; Brunkwall PS
Int Angiol; 2010 Jun; 29(3):232-8. PubMed ID: 20502409
[TBL] [Abstract][Full Text] [Related]
19. Developmental changes of optical properties in neonates determined by near-infrared time-resolved spectroscopy.
Ijichi S; Kusaka T; Isobe K; Okubo K; Kawada K; Namba M; Okada H; Nishida T; Imai T; Itoh S
Pediatr Res; 2005 Sep; 58(3):568-73. PubMed ID: 16148075
[TBL] [Abstract][Full Text] [Related]
20. Local haemodynamic changes during carotid endarterectomy--the influence on cerebral oxygenation.
Kragsterman B; Pärsson H; Bergqvist D
Eur J Vasc Endovasc Surg; 2004 Apr; 27(4):398-402. PubMed ID: 15015190
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]