These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
167 related articles for article (PubMed ID: 23273340)
1. Left atrial appendage closure with the Amplatzer™ Cardiac Plug: impact of shape and device sizing on follow-up leaks. Freixa X; Tzikas A; Sobrino A; Chan J; Basmadjian AJ; Ibrahim R Int J Cardiol; 2013 Sep; 168(2):1023-7. PubMed ID: 23273340 [TBL] [Abstract][Full Text] [Related]
2. Intra-procedural imaging of the left atrial appendage: implications for closure with the Amplatzer™ cardiac plug. Sobrino A; Tzikas A; Freixa X; Pulido A; Chan J; Garceau P; Ibrahim R; Basmadjian AJ Arch Cardiol Mex; 2014; 84(1):17-24. PubMed ID: 24646720 [TBL] [Abstract][Full Text] [Related]
3. Cardiac CT and echocardiographic evaluation of peri-device flow after percutaneous left atrial appendage closure using the AMPLATZER cardiac plug device. Jaguszewski M; Manes C; Puippe G; Salzberg S; Müller M; Falk V; Lüscher T; Luft A; Alkadhi H; Landmesser U Catheter Cardiovasc Interv; 2015 Feb; 85(2):306-12. PubMed ID: 25205611 [TBL] [Abstract][Full Text] [Related]
4. Left atrial appendage closure with the Amplatzer™ Cardiac Plug: Rationale for a higher degree of device oversizing at implantation. Neuzner J; Dietze T; Paliege R; Möller M; Saeed G; Gradaus R Cardiol J; 2015; 22(2):201-5. PubMed ID: 25299502 [TBL] [Abstract][Full Text] [Related]
5. Left atrial appendage occlusion: initial experience with the Amplatzer™ Amulet™. Freixa X; Abualsaud A; Chan J; Nosair M; Tzikas A; Garceau P; Basmadjian A; Ibrahim R Int J Cardiol; 2014 Jul; 174(3):492-6. PubMed ID: 24820753 [TBL] [Abstract][Full Text] [Related]
6. Initial experience with post Lariat left atrial appendage leak closure with Amplatzer septal occluder device and repeat Lariat application. Pillai AM; Kanmanthareddy A; Earnest M; Reddy M; Ferrell R; Nath J; Pillarisetti J; Vallakati A; Lakkireddy D Heart Rhythm; 2014 Nov; 11(11):1877-83. PubMed ID: 24993460 [TBL] [Abstract][Full Text] [Related]
7. Side-by-Side Comparison of LAA Occlusion Performance With the Amplatzer Cardiac Plug and Amplatzer Amulet. Abualsaud A; Freixa X; Tzikas A; Chan J; Garceau P; Basmadjian A; Ibrahim R J Invasive Cardiol; 2016 Jan; 28(1):34-8. PubMed ID: 26716593 [TBL] [Abstract][Full Text] [Related]
9. Safety and effects of volume loading during transesophageal echocardiography in the pre-procedural work-up for left atrial appendage closure. Freitas-Ferraz AB; Bernier M; O'Connor K; Beaudoin J; Champagne J; Paradis JM; O'Hara G; Muntané-Carol G; Alperi A; Faroux L; Junquera L; Rodés-Cabau J Cardiovasc Ultrasound; 2021 Jan; 19(1):3. PubMed ID: 33388071 [TBL] [Abstract][Full Text] [Related]
10. Multimodality imaging in preoperative assessment of left atrial appendage transcatheter occlusion with the Amplatzer Cardiac Plug. Clemente A; Avogliero F; Berti S; Paradossi U; Jamagidze G; Rezzaghi M; Della Latta D; Chiappino D Eur Heart J Cardiovasc Imaging; 2015 Nov; 16(11):1276-87. PubMed ID: 25916628 [TBL] [Abstract][Full Text] [Related]
11. CT sizing for left atrial appendage closure is associated with favourable outcomes for procedural safety. Rajwani A; Nelson AJ; Shirazi MG; Disney PJS; Teo KSL; Wong DTL; Young GD; Worthley SG Eur Heart J Cardiovasc Imaging; 2017 Dec; 18(12):1361-1368. PubMed ID: 28013284 [TBL] [Abstract][Full Text] [Related]
12. Left atrial appendage closure: A single center experience and comparison of two contemporary devices. Figini F; Mazzone P; Regazzoli D; Porata G; Ruparelia N; Giannini F; Stella S; Ancona F; Agricola E; Sora N; Marzi A; Aurelio A; Trevisi N; Della Bella P; Colombo A; Montorfano M Catheter Cardiovasc Interv; 2017 Mar; 89(4):763-772. PubMed ID: 27567013 [TBL] [Abstract][Full Text] [Related]
13. Comparing Measurements of CT Angiography, TEE, and Fluoroscopy of the Left Atrial Appendage for Percutaneous Closure. Saw J; Fahmy P; Spencer R; Prakash R; McLaughlin P; Nicolaou S; Tsang M J Cardiovasc Electrophysiol; 2016 Apr; 27(4):414-22. PubMed ID: 26728988 [TBL] [Abstract][Full Text] [Related]
14. Long-term follow-up after left atrial appendage occlusion with comparison of transesophageal echocardiography versus computed tomography to guide medical therapy and data about postclosure cardioversion. Berte B; Jost CA; Maurer D; Fäh-Gunz A; Pillois X; Naegeli B; Pfyffer M; Sütsch G; Scharf C J Cardiovasc Electrophysiol; 2017 Oct; 28(10):1140-1150. PubMed ID: 28675629 [TBL] [Abstract][Full Text] [Related]
15. Incidence and Clinical Impact of Device-Associated Thrombus and Peri-Device Leak Following Left Atrial Appendage Closure With the Amplatzer Cardiac Plug. Saw J; Tzikas A; Shakir S; Gafoor S; Omran H; Nielsen-Kudsk JE; Kefer J; Aminian A; Berti S; Santoro G; Nietlispach F; Moschovitis A; Cruz-Gonzalez I; Stammen F; Tichelbäcker T; Freixa X; Ibrahim R; Schillinger W; Meier B; Sievert H; Gloekler S JACC Cardiovasc Interv; 2017 Feb; 10(4):391-399. PubMed ID: 28231907 [TBL] [Abstract][Full Text] [Related]
16. Extending percutaneous left atrial appendage closure indications using the AMPLATZER™ Cardiac Plug device in patients with persistent left atrial appendage thrombus: The thrombus trapping technique. Jalal Z; Iriart X; Dinet ML; Selly JB; Tafer N; Renou P; Sibon I; Thambo JB Arch Cardiovasc Dis; 2016 Dec; 109(12):659-666. PubMed ID: 27402154 [TBL] [Abstract][Full Text] [Related]
17. Left atrial appendage patency and device-related thrombus after percutaneous left atrial appendage occlusion: a computed tomography study. Cochet H; Iriart X; Sridi S; Camaioni C; Corneloup O; Montaudon M; Laurent F; Selmi W; Renou P; Jalal Z; Thambo JB Eur Heart J Cardiovasc Imaging; 2018 Dec; 19(12):1351-1361. PubMed ID: 29415203 [TBL] [Abstract][Full Text] [Related]
18. Left atrial appendage morphology, echocardiographic characterization, procedural data and in-hospital outcome of patients receiving left atrial appendage occlusion device implantation: a prospective observational study. Fastner C; Behnes M; Sartorius B; Yildiz M; Mashayekhi K; El-Battrawy I; Lehmann R; Baumann S; Becher T; Borggrefe M; Akin I BMC Cardiovasc Disord; 2016 Jan; 16():25. PubMed ID: 26822890 [TBL] [Abstract][Full Text] [Related]
19. Left atrial appendage closure with AMPLATZER cardiac plug for stroke prevention in atrial fibrillation: initial Asia-Pacific experience. Lam YY; Yip GW; Yu CM; Chan WW; Cheng BC; Yan BP; Clugston R; Yong G; Gattorna T; Paul V Catheter Cardiovasc Interv; 2012 Apr; 79(5):794-800. PubMed ID: 21542102 [TBL] [Abstract][Full Text] [Related]
20. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device. Xu B; Betancor J; Sato K; Harb S; Abdur Rehman K; Patel K; Kumar A; Cremer PC; Jaber W; Rodriguez LL; Schoenhagen P; Wazni O J Cardiovasc Comput Tomogr; 2018; 12(1):50-55. PubMed ID: 29223726 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]