BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

687 related articles for article (PubMed ID: 23279593)

  • 1. Effect of catheter tip-tissue surface contact on three-dimensional left atrial and pulmonary vein geometries: potential anatomic distortion of 3D ultrasound, fast anatomical mapping, and merged 3D CT-derived images.
    Okumura Y; Watanabe I; Kofune M; Nagashima K; Sonoda K; Mano H; Ohkubo K; Nakai T; Sasaki N; Kogawa R; Maruyama A; Hirayama A
    J Cardiovasc Electrophysiol; 2013 Mar; 24(3):259-66. PubMed ID: 23279593
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of catheter tip-tissue contact on three-dimensional left atrial geometries: Relationship between the external structures and anatomic distortion of 3D fast anatomical mapping and high contact force guided images.
    Anjo N; Nakahara S; Okumura Y; Hori Y; Nagashima K; Komatsu T; Hayashi A; Kobayashi S; Sakai Y; Taguchi I
    Int J Cardiol; 2016 Nov; 222():202-208. PubMed ID: 27497095
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anatomical mapping for atrial fibrillation ablation: a head-to-head comparison of ultrasound-assisted reconstruction versus fast anatomical mapping.
    Rordorf R; Chieffo E; Savastano S; Vicentini A; Petracci B; De Regibus V; Valentini A; Klersy C; Dore R; Landolina M
    Pacing Clin Electrophysiol; 2015 Feb; 38(2):187-95. PubMed ID: 25469451
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system.
    Okumura Y; Henz BD; Johnson SB; Bunch TJ; O'Brien CJ; Hodge DO; Altman A; Govari A; Packer DL
    Circ Arrhythm Electrophysiol; 2008 Jun; 1(2):110-9. PubMed ID: 19808401
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relations between contact force, bipolar voltage amplitude, and mapping point distance from the left atrial surfaces of 3D ultrasound- and merged 3D CT-derived images: Implication for atrial fibrillation mapping and ablation.
    Sasaki N; Okumura Y; Watanabe I; Sonoda K; Kogawa R; Takahashi K; Iso K; Nakahara S; Maruyama A; Takemura S; Hirayama A
    Heart Rhythm; 2015 Jan; 12(1):36-43. PubMed ID: 25218838
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: a single-centre prospective study.
    Da Costa A; Ben H'dech M; Romeyer-Bouchard C; Bisch L; Gate-Martinet A; Levallois M; Isaaz K
    Arch Cardiovasc Dis; 2013; 106(8-9):423-32. PubMed ID: 23906679
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Left atrial model reconstruction in atrial fibrillation ablation: reliability of new mapping and complex impedance systems.
    Bonso A; Fantinel M; Scalchi G; Ferrara S; Indiani S; Calore F; Licciardello C
    Europace; 2017 Nov; 19(11):1804-1809. PubMed ID: 27702853
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation.
    Nakagawa H; Kautzner J; Natale A; Peichl P; Cihak R; Wichterle D; Ikeda A; Santangeli P; Di Biase L; Jackman WM
    Circ Arrhythm Electrophysiol; 2013 Aug; 6(4):746-53. PubMed ID: 23873143
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation.
    Dong J; Dickfeld T; Dalal D; Cheema A; Vasamreddy CR; Henrikson CA; Marine JE; Halperin HR; Berger RD; Lima JA; Bluemke DA; Calkins H
    J Cardiovasc Electrophysiol; 2006 May; 17(5):459-66. PubMed ID: 16684014
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electroanatomic reconstruction of the left atrium, pulmonary veins, and esophagus compared with the "true anatomy" on multislice computed tomography in patients undergoing catheter ablation of atrial fibrillation.
    Piorkowski C; Hindricks G; Schreiber D; Tanner H; Weise W; Koch A; Gerds-Li JH; Kottkamp H
    Heart Rhythm; 2006 Mar; 3(3):317-27. PubMed ID: 16500305
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does a patent foramen ovale matter when using a remote-controlled magnetic system for pulmonary vein isolation?
    Gate-Martinet A; Da Costa A; Romeyer-Bouchard C; Bisch L; Levallois M; Isaaz K
    Arch Cardiovasc Dis; 2014 Feb; 107(2):88-95. PubMed ID: 24556188
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Catheter ablation of atrial fibrillation supported by novel nonfluoroscopic 4D navigation technology.
    Rolf S; John S; Gaspar T; Dinov B; Kircher S; Huo Y; Bollmann A; Richter S; Arya A; Hindricks G; Piorkowski C; Sommer P
    Heart Rhythm; 2013 Sep; 10(9):1293-300. PubMed ID: 23680898
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia.
    Knecht S; Skali H; O'Neill MD; Wright M; Matsuo S; Chaudhry GM; Haffajee CI; Nault I; Gijsbers GH; Sacher F; Laurent F; Montaudon M; Corneloup O; Hocini M; Haïssaguerre M; Orlov MV; Jaïs P
    Europace; 2008 Aug; 10(8):931-8. PubMed ID: 18511437
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Linear ablation of left atrium for the treatment of atrial fibrillation guided by double Lasso catheters and three dimensional electroanatomical mapping.
    Ma J; Tang K; Ma FS; Jia YH; Zhang S; Huang CX
    Chin Med J (Engl); 2006 Dec; 119(24):2042-8. PubMed ID: 17199954
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraprocedural volume imaging of the left atrium and pulmonary veins with rotational X-ray angiography: implications for catheter ablation of atrial fibrillation.
    Thiagalingam A; Manzke R; D'Avila A; Ho I; Locke AH; Ruskin JN; Chan RC; Reddy VY
    J Cardiovasc Electrophysiol; 2008 Mar; 19(3):293-300. PubMed ID: 18005027
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fusion of multislice computed tomography and electroanatomical mapping data for 3D navigation of left and right atrial catheter ablation.
    Feuchtner GM; Dichtl W; DeFrance T; Stühlinger M; Klauser A; Berger T; Junker D; Spuller K; Pachinger O; zur Nedden D; Hintringer F
    Eur J Radiol; 2008 Dec; 68(3):456-64. PubMed ID: 17913424
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reconstruction left atrium and isolation pulmonary veins of paroxysmal atrial fibrillation using single contact force catheter with zero x-ray exposure: A CONSORT Study.
    Zhang JQ; Yu RH; Liang JB; Long Y; Sang CH; Ma CS; Dong JZ
    Medicine (Baltimore); 2017 Oct; 96(41):e7726. PubMed ID: 29019873
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of 3D guided electroanatomic mapping for ablation of atrial fibrillation in reference to CT-Scan image integration.
    de Chillou C; Andronache M; Abdelaal A; Ernst Y; Magnin-Poull I; Magdi M; Zhang N; Tissier S; Mandry D; Barbary C; Régent D; Aliot E
    J Interv Card Electrophysiol; 2008 Dec; 23(3):175-81. PubMed ID: 18821007
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation.
    Makimoto H; Lin T; Rillig A; Metzner A; Wohlmuth P; Arya A; Antz M; Mathew S; Deiss S; Wissner E; Rausch P; Bardyszewski A; Kamioka M; Li X; Kuck KH; Ouyang F; Tilz RR
    Circ Arrhythm Electrophysiol; 2014 Feb; 7(1):46-54. PubMed ID: 24363353
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Left Atrial Bipolar Voltage and Scar Using Multielectrode Fast Automated Mapping versus Point-by-Point Contact Electroanatomic Mapping in Patients With Atrial Fibrillation Undergoing Repeat Ablation.
    Liang JJ; Elafros MA; Muser D; Pathak RK; Santangeli P; Supple GE; Schaller RD; Frankel DS; Dixit S
    J Cardiovasc Electrophysiol; 2017 Mar; 28(3):280-288. PubMed ID: 27997060
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 35.