These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 23285623)

  • 21. Systems view of optimizing metal on metal bearings.
    Schey JA
    Clin Orthop Relat Res; 1996 Aug; (329 Suppl):S115-27. PubMed ID: 8769329
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses.
    Udofia IJ; Jin ZM
    J Biomech; 2003 Apr; 36(4):537-44. PubMed ID: 12600344
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement.
    Yew A; Udofia I; Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):27-34. PubMed ID: 14982343
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.
    Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J
    J Biomech; 2006; 39(12):2274-81. PubMed ID: 16143337
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A new model for synovial joint lubrication.
    Tandon PN; Bong NH; Kushwaha K
    Int J Biomed Comput; 1994 Mar; 35(2):125-40. PubMed ID: 8194864
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of simplifications of bone and components inclination on the elastohydrodynamic lubrication modeling of metal-on-metal hip resurfacing prosthesis.
    Meng Q; Liu F; Fisher J; Jin Z
    Proc Inst Mech Eng H; 2013 May; 227(5):523-34. PubMed ID: 23637262
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Does surface wettability influence the friction and wear of large-diameter CoCrMo alloy hip resurfacings?
    Curran S; Hoskin T; Williams S; Scholes SC; Kinbrum A; Unsworth A
    Proc Inst Mech Eng H; 2013 Aug; 227(8):847-58. PubMed ID: 23852389
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The boundary lubrication of chemically grafted and cross-linked hyaluronic acid in phosphate buffered saline and lipid solutions measured by the surface forces apparatus.
    Yu J; Banquy X; Greene GW; Lowrey DD; Israelachvili JN
    Langmuir; 2012 Jan; 28(4):2244-50. PubMed ID: 22148857
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Lubrication and cartilage.
    Wright V; Dowson D
    J Anat; 1976 Feb; 121(Pt 1):107-18. PubMed ID: 3490
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
    Mabuchi K; Sakai R; Ota M; Ujihira M
    Clin Biomech (Bristol, Avon); 2004 May; 19(4):362-9. PubMed ID: 15109756
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [The development of research in tribology of artificial joints].
    Dai Z; Gong J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Jun; 23(3):669-73. PubMed ID: 16856413
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Prediction of lubricating film thickness in UHMWPE hip joint replacements.
    Jalali-Vahid D; Jagatia M; Jin ZM; Dowson D
    J Biomech; 2001 Feb; 34(2):261-6. PubMed ID: 11165292
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    J Biomech; 2006; 39(5):905-14. PubMed ID: 16199048
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies.
    Vassiliou K; Elfick AP; Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2006 Feb; 220(2):269-77. PubMed ID: 16669393
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A porous implant model for a knee joint.
    Tandon PN; Chaurasia A
    Int J Biomed Comput; 1991 Oct; 29(1):45-59. PubMed ID: 1959981
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Boundary lubricating property of synovial fluid on artificial material and lubrication of artificial joints.
    Tsukamoto Y; Yamamoto M; Mabuchi K; Morita M; Sasada T
    Nihon Seikeigeka Gakkai Zasshi; 1983 Jan; 57(1):91-9. PubMed ID: 6864038
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Lubrication regimes in lumbar total disc arthroplasty.
    Shaheen A; Shepherd DE
    Proc Inst Mech Eng H; 2007 Aug; 221(6):621-7. PubMed ID: 17937201
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
    Gao L; Wang F; Yang P; Jin Z
    Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Steady-state elastohydrodynamic lubrication analysis of a metal-on-metal hip implant employing a metallic cup with an ultra-high molecular weight polyethylene backing.
    Liu F; Wang FC; Jin ZM; Hirt F; Rieker C; Grigoris P
    Proc Inst Mech Eng H; 2004; 218(4):261-70. PubMed ID: 15376728
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Predictive wear modeling of the articulating metal-on-metal hip replacements.
    Gao L; Dowson D; Hewson RW
    J Biomed Mater Res B Appl Biomater; 2017 Apr; 105(3):497-506. PubMed ID: 26559657
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.