BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 23286888)

  • 1. [Cerebral near-infrared spectroscopy (NIRS) in paediatric anaesthesia].
    Raux O; Sola C; Macq C; Dadure C
    Ann Fr Anesth Reanim; 2013 Jan; 32(1):e49-53. PubMed ID: 23286888
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation].
    Abdul-Khaliq H; Troitzsch D; Berger F; Lange PE
    Biomed Tech (Berl); 2000 Nov; 45(11):328-32. PubMed ID: 11155535
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of cerebral venous oxyhemoglobin saturation in children by near-infrared spectroscopy and partial jugular venous occlusion.
    Yoxall CW; Weindling AM; Dawani NH; Peart I
    Pediatr Res; 1995 Sep; 38(3):319-23. PubMed ID: 7494653
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Regional differences in tissue oxygenation during cardiopulmonary bypass for correction of congenital heart disease in neonates and small infants: relevance of near-infrared spectroscopy.
    Redlin M; Koster A; Huebler M; Boettcher W; Nagdyman N; Hetzer R; Kuppe H; Kuebler WM
    J Thorac Cardiovasc Surg; 2008 Oct; 136(4):962-7. PubMed ID: 18954637
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Near-infrared spectroscopy cerebral and somatic (renal) oxygen saturation correlation to continuous venous oxygen saturation via intravenous oximetry catheter.
    Marimón GA; Dockery WK; Sheridan MJ; Agarwal S
    J Crit Care; 2012 Jun; 27(3):314.e13-8. PubMed ID: 22172794
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients.
    Tortoriello TA; Stayer SA; Mott AR; McKenzie ED; Fraser CD; Andropoulos DB; Chang AC
    Paediatr Anaesth; 2005 Jun; 15(6):495-503. PubMed ID: 15910351
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noninvasive monitoring of central venous oxygen saturation by jugular transcutaneous near-infrared spectroscopy in pediatric patients undergoing congenital cardiac surgery.
    Altun D; Doğan A; Arnaz A; Yüksek A; Yalçinbaş YK; Türköz R; Sarioğlu T
    Turk J Med Sci; 2020 Aug; 50(5):1280-1287. PubMed ID: 32490634
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monitoring of regional tissue oxygenation with near-infrared spectroscopy during the early postoperative course after superior cavopulmonary anastomosis.
    Hansen JH; Schlangen J; Armbrust S; Jung O; Scheewe J; Kramer HH
    Eur J Cardiothorac Surg; 2013 Feb; 43(2):e37-43. PubMed ID: 23129357
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of cerebral oxygen balance during deep hypothermic circulatory arrest by continuous jugular bulb venous saturation and near-infrared spectroscopy.
    Leyvi G; Bello R; Wasnick JD; Plestis K
    J Cardiothorac Vasc Anesth; 2006 Dec; 20(6):826-33. PubMed ID: 17138088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determinants of cerebral fractional oxygen extraction using near infrared spectroscopy in preterm neonates.
    Wardle SP; Yoxall CW; Weindling AM
    J Cereb Blood Flow Metab; 2000 Feb; 20(2):272-9. PubMed ID: 10698064
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Role of intraoperative regional oxygen saturation using near infrared spectroscopy in the prediction of low output syndrome after pediatric heart surgery.
    Zulueta JL; Vida VL; Perisinotto E; Pittarello D; Stellin G
    J Card Surg; 2013 Jul; 28(4):446-52. PubMed ID: 23734582
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Near Infrared Spectroscopy for cerebral monitoring during cardiovascular surgery].
    La Monaca M; David A; Gaeta R; Lentini S
    Clin Ter; 2010; 161(6):549-53. PubMed ID: 21181086
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Near-infrared spectroscopy correlates with continuous superior vena cava oxygen saturation in pediatric cardiac surgery patients.
    Ranucci M; Isgrò G; De la Torre T; Romitti F; Conti D; Carlucci C
    Paediatr Anaesth; 2008 Dec; 18(12):1163-9. PubMed ID: 19076569
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cerebral oxygenation measured by near-infrared spectroscopy: comparison with jugular bulb oximetry.
    Daubeney PE; Pilkington SN; Janke E; Charlton GA; Smith DC; Webber SA
    Ann Thorac Surg; 1996 Mar; 61(3):930-4. PubMed ID: 8619720
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Monitoring cerebral oxygenation using near infrared spectroscopy during cardiopulmonary bypass surgery].
    Teng YC; Ding HS; Gong QC; Jia ZS; Huang L; Wang PY
    Guang Pu Xue Yu Guang Pu Fen Xi; 2006 May; 26(5):828-32. PubMed ID: 16883847
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cerebral oximetry for pediatric anesthesia: why do intelligent clinicians disagree?
    Kasman N; Brady K
    Paediatr Anaesth; 2011 May; 21(5):473-8. PubMed ID: 21414077
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcutaneous regional venous oximetry: a feasibility study.
    Thiele RH; Tucker-Schwartz JM; Lu Y; Gillies GT; Durieux ME
    Anesth Analg; 2011 Jun; 112(6):1353-7. PubMed ID: 21613200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Near infrared spectroscopy in children at high risk of low perfusion.
    Mittnacht AJ
    Curr Opin Anaesthesiol; 2010 Jun; 23(3):342-7. PubMed ID: 20421789
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of volume resuscitation on regional perfusion in dehydrated pediatric patients as measured by two-site near-infrared spectroscopy.
    Hanson SJ; Berens RJ; Havens PL; Kim MK; Hoffman GM
    Pediatr Emerg Care; 2009 Mar; 25(3):150-3. PubMed ID: 19262423
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Regional haemoglobin oxygen saturation during surgical haemorrhage.
    Torella F; McCollum CN
    Minerva Med; 2004 Oct; 95(5):461-7. PubMed ID: 15467521
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.