These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
314 related articles for article (PubMed ID: 23288435)
1. Appropriate collimators in a small animal SPECT scanner with CZT detector. Higaki Y; Kobayashi M; Uehara T; Hanaoka H; Arano Y; Kawai K Ann Nucl Med; 2013 Apr; 27(3):271-8. PubMed ID: 23288435 [TBL] [Abstract][Full Text] [Related]
2. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors. Kobayashi M; Matsunari I; Nishi K; Mizutani A; Miyazaki Y; Ogai K; Sugama J; Shiba K; Kawai K; Kinuya S Ann Nucl Med; 2016 May; 30(4):263-71. PubMed ID: 26747655 [TBL] [Abstract][Full Text] [Related]
3. Performance evaluation of the eXplore speCZT preclinical imaging system. Matsunari I; Miyazaki Y; Kobayashi M; Nishi K; Mizutani A; Kawai K; Hayashi A; Komatsu R; Yonezawa S; Kinuya S Ann Nucl Med; 2014 Jun; 28(5):484-97. PubMed ID: 24610679 [TBL] [Abstract][Full Text] [Related]
4. Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector. Ogawa K; Ohmura N; Iida H; Nakamura K; Nakahara T; Kubo A Ann Nucl Med; 2009 Oct; 23(8):763-70. PubMed ID: 19680739 [TBL] [Abstract][Full Text] [Related]
5. Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators. Fan P; Hutton BF; Holstensson M; Ljungberg M; Pretorius PH; Prasad R; Ma T; Liu Y; Wang S; Thorn SL; Stacy MR; Sinusas AJ; Liu C Med Phys; 2015 Dec; 42(12):6895-911. PubMed ID: 26632046 [TBL] [Abstract][Full Text] [Related]
6. Design and evaluation of two multi-pinhole collimators for brain SPECT. Chen L; Tsui BMW; Mok GSP Ann Nucl Med; 2017 Oct; 31(8):636-648. PubMed ID: 28755084 [TBL] [Abstract][Full Text] [Related]
7. Performance characteristics of a novel clustered multi-pinhole technology for simultaneous high-resolution SPECT/PET. Miwa K; Inubushi M; Takeuchi Y; Katafuchi T; Koizumi M; Saga T; Sasaki M Ann Nucl Med; 2015 Jun; 29(5):460-6. PubMed ID: 25894055 [TBL] [Abstract][Full Text] [Related]
8. Imaging capabilities of the Inveon SPECT system using single-and multipinhole collimators. Boisson F; Zahra D; Parmar A; Gregoire MC; Meikle SR; Hamse H; Reilhac A J Nucl Med; 2013 Oct; 54(10):1833-40. PubMed ID: 24009279 [TBL] [Abstract][Full Text] [Related]
9. Iodine-131 imaging using 284 keV photons with a small animal CZT-SPECT system dedicated to low-medium-energy photon detection. Kojima A; Gotoh K; Shimamoto M; Hasegawa K; Okada S Ann Nucl Med; 2016 Feb; 30(2):169-75. PubMed ID: 26395374 [TBL] [Abstract][Full Text] [Related]
10. Design and evaluation of an adaptive multipinhole collimator for high-performance clinical and preclinical imaging. Si C; Mok GS; Chen L; Tsui BM Nucl Med Commun; 2016 Mar; 37(3):313-21. PubMed ID: 26528787 [TBL] [Abstract][Full Text] [Related]
11. Performance assessment of the ALBIRA II pre-clinical SPECT S102 system for Attarwala AA; Hardiansyah D; Romanó C; Jiménez-Franco LD; Roscher M; Wängler B; Glatting G Ann Nucl Med; 2021 Jan; 35(1):111-120. PubMed ID: 33180260 [TBL] [Abstract][Full Text] [Related]
12. Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments. Pourmoghaddas A; Wells RG Med Phys; 2016 Jan; 43(1):44. PubMed ID: 26745898 [TBL] [Abstract][Full Text] [Related]
14. Experimental evaluation of the GE NM/CT 870 CZT clinical SPECT system equipped with WEHR and MEHRS collimator. Ito T; Matsusaka Y; Onoguchi M; Ichikawa H; Okuda K; Shibutani T; Shishido M; Sato K J Appl Clin Med Phys; 2021 Feb; 22(2):165-177. PubMed ID: 33426812 [TBL] [Abstract][Full Text] [Related]
15. Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of Huh Y; Caravaca J; Kim J; Cui Y; Huang Q; Gullberg G; Seo Y Med Phys; 2023 Jun; 50(6):3726-3737. PubMed ID: 36916755 [TBL] [Abstract][Full Text] [Related]
16. Initial clinical experience with dedicated multi-pinhole (MPH) collimator for Képes Z; Kukuts K; Oszlánszki A; Mihovk I; Krizsán Á; Barna S; Robinson A; Deidda D; Mester J; Varga J; Garai I; Forgács A Hell J Nucl Med; 2022; 25(2):143-147. PubMed ID: 35913861 [TBL] [Abstract][Full Text] [Related]
17. Performance evaluation of a novel multi-pinhole collimator for dopamine transporter SPECT. Tecklenburg K; Forgács A; Apostolova I; Lehnert W; Klutmann S; Csirik J; Garutti E; Buchert R Phys Med Biol; 2020 Aug; 65(16):165015. PubMed ID: 32369781 [TBL] [Abstract][Full Text] [Related]
18. Kidney dynamic SPECT acquisition on a CZT swiveling-detector ring camera: an in vivo pilot study. Hesse M; Dupont F; Mourad N; Babczenko P; Beaurin G; Xhema D; Bonaccorsi-Riani E; Jamar F; Lhommel R BMC Med Imaging; 2024 Apr; 24(1):94. PubMed ID: 38649862 [TBL] [Abstract][Full Text] [Related]
19. U-SPECT-II: An Ultra-High-Resolution Device for Molecular Small-Animal Imaging. van der Have F; Vastenhouw B; Ramakers RM; Branderhorst W; Krah JO; Ji C; Staelens SG; Beekman FJ J Nucl Med; 2009 Apr; 50(4):599-605. PubMed ID: 19289425 [TBL] [Abstract][Full Text] [Related]
20. A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation. Liu CJ; Cheng JS; Chen YC; Huang YH; Yen RF Ann Nucl Med; 2015 May; 29(4):342-50. PubMed ID: 25628019 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]