698 related articles for article (PubMed ID: 23290715)
21. EBT2 film as a depth-dose measurement tool for radiotherapy beams over a wide range of energies and modalities.
Arjomandy B; Tailor R; Zhao L; Devic S
Med Phys; 2012 Feb; 39(2):912-21. PubMed ID: 22320801
[TBL] [Abstract][Full Text] [Related]
22. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
23. Dosimetry intercomparison using a 35-keV X-ray synchrotron beam.
Oves SD; Hogstrom KR; Ham K; Sajo E; Dugas JP
Eur J Radiol; 2008 Dec; 68(3 Suppl):S121-5. PubMed ID: 18586431
[TBL] [Abstract][Full Text] [Related]
24. The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy.
Arnfield MR; Otto K; Aroumougame VR; Alkins RD
Med Phys; 2005 Jan; 32(1):12-8. PubMed ID: 15719949
[TBL] [Abstract][Full Text] [Related]
25. Practical use of Gafchromic(®) EBT films in electron beams for in-phantom dose distribution measurements and monitor units verification.
El Barouky J; Fournier-Bidoz N; Mazal A; Fares G; Rosenwald JC
Phys Med; 2011 Apr; 27(2):81-8. PubMed ID: 20627785
[TBL] [Abstract][Full Text] [Related]
26. Characterization and use of EBT radiochromic film for IMRT dose verification.
Zeidan OA; Stephenson SA; Meeks SL; Wagner TH; Willoughby TR; Kupelian PA; Langen KM
Med Phys; 2006 Nov; 33(11):4064-72. PubMed ID: 17153386
[TBL] [Abstract][Full Text] [Related]
27. Analysis of various beamlet sizes for IMRT with 6 MV photons.
Sohn JW; Dempsey JF; Suh TS; Low DA
Med Phys; 2003 Sep; 30(9):2432-9. PubMed ID: 14528965
[TBL] [Abstract][Full Text] [Related]
28. Superficial and peripheral dose in compensator-based FFF beam IMRT.
Zhang DG; Feygelman V; Moros EG; Latifi K; Hoffe S; Frakes J; Zhang GG
J Appl Clin Med Phys; 2017 Jan; 18(1):151-156. PubMed ID: 28291940
[TBL] [Abstract][Full Text] [Related]
29. Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification.
Kirov AS; Caravelli G; Palm A; Chui C; LoSasso T
Med Phys; 2006 Oct; 33(10):3690-9. PubMed ID: 17089835
[TBL] [Abstract][Full Text] [Related]
30. Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays.
Dogan N; Glasgow GP
Med Phys; 2003 Dec; 30(12):3091-6. PubMed ID: 14713075
[TBL] [Abstract][Full Text] [Related]
31. Monte Carlo implementation, validation, and characterization of a 120 leaf MLC.
Fix MK; Volken W; Frei D; Frauchiger D; Born EJ; Manser P
Med Phys; 2011 Oct; 38(10):5311-20. PubMed ID: 21992349
[TBL] [Abstract][Full Text] [Related]
32. Commissioning Varian enhanced dynamic wedge in the PINNACLE treatment planning system using Gafchromic EBT film.
Fontanarosa D; Orlandini LC; Andriani I; Bernardi L
Med Phys; 2009 Oct; 36(10):4504-10. PubMed ID: 19928081
[TBL] [Abstract][Full Text] [Related]
33. Matchline dosimetry in step and shoot IMRT fields: a film study.
Tangboonduangjit P; Metcalfe P; Butson M; Quach KY; Rosenfeld A
Phys Med Biol; 2004 Sep; 49(17):N287-92. PubMed ID: 15470934
[TBL] [Abstract][Full Text] [Related]
34. Evaluation of GafChromic EBT prototype B for external beam dose verification.
Todorovic M; Fischer M; Cremers F; Thom E; Schmidt R
Med Phys; 2006 May; 33(5):1321-8. PubMed ID: 16752567
[TBL] [Abstract][Full Text] [Related]
35. EDR2 film dosimetry for IMRT verification using low-energy photon filters.
Yeo IJ; Beiki-Ardakani A; Cho YB; Heydarian M; Zhang T; Islam M
Med Phys; 2004 Jul; 31(7):1960-3. PubMed ID: 15305446
[TBL] [Abstract][Full Text] [Related]
36. Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA.
Olch AJ
Med Phys; 2012 Jan; 39(1):81-6. PubMed ID: 22225277
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator.
Zhu XR; Jursinic PA; Grimm DF; Lopez F; Rownd JJ; Gillin MT
Med Phys; 2002 Aug; 29(8):1687-92. PubMed ID: 12201414
[TBL] [Abstract][Full Text] [Related]
38. Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose.
Palm A; Kirov AS; LoSasso T
Med Phys; 2004 Dec; 31(12):3168-78. PubMed ID: 15651599
[TBL] [Abstract][Full Text] [Related]
39. A comparison of TPS and different measurement techniques in small-field electron beams.
Donmez Kesen N; Cakir A; Okutan M; Bilge H
Med Dosim; 2015; 40(1):9-15. PubMed ID: 25219322
[TBL] [Abstract][Full Text] [Related]
40. Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies.
Chiu-Tsao ST; Ho Y; Shankar R; Wang L; Harrison LB
Med Phys; 2005 Nov; 32(11):3350-4. PubMed ID: 16370422
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]