These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
44. Minimal-SAR RF pulse optimization for parallel transmission in MRI. Liu Y; Ji JX Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5774-7. PubMed ID: 19164029 [TBL] [Abstract][Full Text] [Related]
45. Signal-to-noise ratio comparison of phased-array vs. implantable coil for rat spinal cord MRI. Yung AC; Kozlowski P Magn Reson Imaging; 2007 Oct; 25(8):1215-21. PubMed ID: 17905249 [TBL] [Abstract][Full Text] [Related]
47. Human brain imaging at 9.4 T using a tunable patch antenna for transmission. Hoffmann J; Shajan G; Budde J; Scheffler K; Pohmann R Magn Reson Med; 2013 May; 69(5):1494-500. PubMed ID: 22706783 [TBL] [Abstract][Full Text] [Related]
48. Design and evaluation of a detunable water-based quadrature HEM11 mode dielectric resonator as a new type of volume coil for high field MRI. Aussenhofer SA; Webb AG Magn Reson Med; 2012 Oct; 68(4):1325-31. PubMed ID: 22887743 [TBL] [Abstract][Full Text] [Related]
50. Design and characterization of receive-only surface coil arrays at 3T with integrated solid high permittivity materials. Ruytenberg T; O'Reilly TP; Webb AG J Magn Reson; 2020 Feb; 311():106681. PubMed ID: 31923765 [TBL] [Abstract][Full Text] [Related]
51. Design and evaluation of an RF front-end for 9.4 T human MRI. Shajan G; Hoffmann J; Budde J; Adriany G; Ugurbil K; Pohmann R Magn Reson Med; 2011 Aug; 66(2):596-604. PubMed ID: 21381102 [TBL] [Abstract][Full Text] [Related]
52. Basic considerations on the impact of the coil array on the performance of Transmit SENSE. Katscher U; Röhrs J; Börnert P MAGMA; 2005 May; 18(2):81-8. PubMed ID: 15711852 [TBL] [Abstract][Full Text] [Related]
53. An eight-channel T/R head coil for parallel transmit MRI at 3T using ultra-low output impedance amplifiers. Moody KL; Hollingsworth NA; Zhao F; Nielsen JF; Noll DC; Wright SM; McDougall MP J Magn Reson; 2014 Sep; 246():62-8. PubMed ID: 25072190 [TBL] [Abstract][Full Text] [Related]
54. An orthogonal-based decoupling method for MRI phased array coil design. Li BK; Wang H; Trakic A; Engstrom C; Weber E; Crozier S NMR Biomed; 2012 Jun; 25(6):835-42. PubMed ID: 22134869 [TBL] [Abstract][Full Text] [Related]
55. A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T. Deppe MH; Parra-Robles J; Marshall H; Lanz T; Wild JM Magn Reson Med; 2011 Dec; 66(6):1788-97. PubMed ID: 21574180 [TBL] [Abstract][Full Text] [Related]
56. A theoretical study for the inverse design of an ellipsoidal phased-array breast coil. Li Y; Liu F; Weber E; Li M; Xu W; Crozier S Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():539-42. PubMed ID: 22254367 [TBL] [Abstract][Full Text] [Related]
57. Slotted surface coil with reduced g-factor for SENSE imaging. Ocegueda K; Rodriguez AO Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1904-6. PubMed ID: 17946922 [TBL] [Abstract][Full Text] [Related]