21. Comparison of haemoglobin assessments by HemoCue and two automated haematology analysers in young Laotian children.
Hinnouho GM; Barffour MA; Wessells KR; Brown KH; Kounnavong S; Chanhthavong B; Ratsavong K; Kewcharoenwong C; Hess SY
J Clin Pathol; 2018 Jun; 71(6):532-538. PubMed ID: 29197856
[TBL] [Abstract][Full Text] [Related]
22. Assessment of haemoglobin measurement by several methods - blood gas analyser, capillary and venous HemoCue
Wittenmeier E; Lesmeister L; Pirlich N; Dette F; Schmidtmann I; Mildenberger E
Anaesthesia; 2019 Feb; 74(2):197-202. PubMed ID: 30427065
[TBL] [Abstract][Full Text] [Related]
23. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study.
Neufeld L; García-Guerra A; Sánchez-Francia D; Newton-Sánchez O; Ramírez-Villalobos MD; Rivera-Dommarco J
Salud Publica Mex; 2002; 44(3):219-27. PubMed ID: 12132319
[TBL] [Abstract][Full Text] [Related]
24. Capillary and venous haemoglobin levels in blood donors: a 42-month study of 36,258 paired samples.
Tong E; Murphy WG; Kinsella A; Darragh E; Woods J; Murphy C; McSweeney E
Vox Sang; 2010 May; 98(4):547-53. PubMed ID: 19951306
[TBL] [Abstract][Full Text] [Related]
25. [Determining the haemoglobin concentration in general practice using the HemoCue method: useful but not completely reliable].
Eekhof JA; Groeneveld Y
Ned Tijdschr Geneeskd; 2008 Oct; 152(42):2294-7. PubMed ID: 19009880
[TBL] [Abstract][Full Text] [Related]
26. Validity of the haemoglobin colour scale in blood donor screening.
Lewis SM; Emmanuel J
Vox Sang; 2001 Jan; 80(1):28-33. PubMed ID: 11339065
[TBL] [Abstract][Full Text] [Related]
27. A non-invasive strategy for haemoglobin screening of blood donors.
Pagliaro P; Belardinelli A; Boko V; Salamon P; Manfroi S; Tazzari PL
Blood Transfus; 2014 Oct; 12(4):458-63. PubMed ID: 24960642
[TBL] [Abstract][Full Text] [Related]
28. Estimation of blood haemoglobin concentration using the HemoCue during caesarean section: the effect of sampling site.
Richards NA; Boyce H; Yentis SM
Int J Obstet Anesth; 2010 Jan; 19(1):67-70. PubMed ID: 19945277
[TBL] [Abstract][Full Text] [Related]
29. Baseline haemoglobin variability by measurement technique in pregnant people on the day of childbirth.
Caulfield KC; McMahon O; Dennis AT
Anaesthesia; 2024 Feb; 79(2):178-185. PubMed ID: 37990621
[TBL] [Abstract][Full Text] [Related]
30. Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening.
Morris LD; Osei-Bimpong A; McKeown D; Roper D; Lewis SM
Vox Sang; 2007 Jul; 93(1):64-9. PubMed ID: 17547567
[TBL] [Abstract][Full Text] [Related]
31. The new noninvasive occlusion spectroscopy hemoglobin measurement method: a reliable and easy anemia screening test for blood donors.
Pinto M; Barjas-Castro ML; Nascimento S; Falconi MA; Zulli R; Castro V
Transfusion; 2013 Apr; 53(4):766-9. PubMed ID: 22803617
[TBL] [Abstract][Full Text] [Related]
32. Comparison of the accuracy of capillary hemoglobin estimation and venous hemoglobin estimation by two models of HemoCue against automated cell counter hemoglobin measurement.
Jain A; Chowdhury N
Asian J Transfus Sci; 2020; 14(1):49-53. PubMed ID: 33162706
[TBL] [Abstract][Full Text] [Related]
33. Evaluation of new non-invasive & conventional invasive methods of haemoglobin estimation in blood donors.
Rout D; Sachdev S; Marwaha N
Indian J Med Res; 2019 Jun; 149(6):755-762. PubMed ID: 31496528
[TBL] [Abstract][Full Text] [Related]
34. Comparison of Massimo Pronto-7 and HemoCue Hb 201+ with laboratory haemoglobin estimation: a clinical study.
Hiscock R; Simmons S; Carstensen B; Gurrin L
Anaesth Intensive Care; 2014 Sep; 42(5):608-13. PubMed ID: 25233174
[TBL] [Abstract][Full Text] [Related]
35. Variation in haemoglobin measurement across different HemoCue devices and device operators in rural Cambodia.
Rappaport AI; Barr SI; Green TJ; Karakochuk CD
J Clin Pathol; 2017 Jul; 70(7):615-618. PubMed ID: 28275044
[TBL] [Abstract][Full Text] [Related]
36. The impact of noninvasive, capillary, and venous hemoglobin screening on donor deferrals and the hemoglobin content of red blood cells concentrates: a prospective study.
Sümnig A; Hron G; Westphal A; Petersmann A; Kohlmann T; Greinacher A; Thiele T
Transfusion; 2015 Dec; 55(12):2847-54. PubMed ID: 26177874
[TBL] [Abstract][Full Text] [Related]
37. A noninvasive strategy for screening prospective blood donors for anemia.
Lotfi R; Wernet D; Starke U; Northoff H; Cassens U
Transfusion; 2005 Oct; 45(10):1585-92. PubMed ID: 16181209
[TBL] [Abstract][Full Text] [Related]
38. Evaluation of capillary haemoglobin determination for anaemia screening in blood donation settings.
Daves M; Cemin R; Zagler EM; Joos A; Platzgummer S; Hueber R; Lippi G
Blood Transfus; 2016 Sep; 14(5):387-90. PubMed ID: 27136435
[TBL] [Abstract][Full Text] [Related]
39. Non-invasive hemoglobin measurement devices require refinement to match diagnostic performance with their high level of usability and acceptability.
Young MF; Raines K; Jameel F; Sidi M; Oliveira-Streiff S; Nwajei P; McGlamry K; Ou J; Oladele A; Suchdev PS
PLoS One; 2021; 16(7):e0254629. PubMed ID: 34270591
[TBL] [Abstract][Full Text] [Related]
40. Blood donor rejection rate: HemoCue hemoglobin analyzer vs. microhematocrit.
Russell BL; Martin SM
Clin Lab Sci; 1997; 10(6):321-4. PubMed ID: 10175331
[TBL] [Abstract][Full Text] [Related]