These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 23294781)

  • 1. Evaluation of a continuous blood glucose monitoring system using central venous microdialysis.
    Schierenbeck F; Franco-Cereceda A; Liska J
    J Diabetes Sci Technol; 2012 Nov; 6(6):1365-71. PubMed ID: 23294781
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a continuous blood glucose monitoring system using a central venous catheter with an integrated microdialysis function.
    Schierenbeck F; Öwall A; Franco-Cereceda A; Liska J
    Diabetes Technol Ther; 2013 Jan; 15(1):26-31. PubMed ID: 23137021
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of intravascular microdialysis for continuous blood glucose monitoring in hypoglycemia: an animal model.
    Schierenbeck F; Wallin M; Franco-Cereceda A; Liska J
    J Diabetes Sci Technol; 2014 Jul; 8(4):839-44. PubMed ID: 24876424
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of 2 Different Continuous Glucose Monitoring Systems in Patients Undergoing Cardiac Surgery.
    Schierenbeck F; Franco-Cereceda A; Liska J
    J Diabetes Sci Technol; 2017 Jan; 11(1):108-116. PubMed ID: 27257168
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Introducing intravascular microdialysis for continuous lactate monitoring in patients undergoing cardiac surgery: a prospective observational study.
    Schierenbeck F; Nijsten MW; Franco-Cereceda A; Liska J
    Crit Care; 2014 Mar; 18(2):R56. PubMed ID: 24684807
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous on-line glucose measurement by microdialysis in a central vein. A pilot study.
    Blixt C; Rooyackers O; Isaksson B; Wernerman J
    Crit Care; 2013 May; 17(3):R87. PubMed ID: 23663747
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Point and trend accuracy of a continuous intravenous microdialysis-based glucose-monitoring device in critically ill patients: a prospective study.
    Leopold JH; van Hooijdonk RTM; Boshuizen M; Winters T; Bos LD; Abu-Hanna A; Hoek AMT; Fischer JC; van Dongen-Lases EC; Schultz MJ
    Ann Intensive Care; 2016 Dec; 6(1):68. PubMed ID: 27436191
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis: continuous glucose monitoring in the intensive care unit.
    Kenneth Ward W
    J Diabetes Sci Technol; 2012 Nov; 6(6):1372-4. PubMed ID: 23294782
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of changes in blood glucose concentration with intravascular microdialysis.
    Fischer MO; Gouëzel C; Fradin S; Saplacan V; Gérard JL; Fellahi JL; Hanouz JL
    J Clin Monit Comput; 2018 Dec; 32(6):1135-1142. PubMed ID: 29404891
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuous Monitoring of Lactate Using Intravascular Microdialysis in High-Risk Cardiac Surgery: A Prospective Observational Study.
    Lenkin PI; Smetkin AA; Hussain A; Lenkin AI; Paromov KV; Ushakov AA; Krygina MM; Kuzkov VV; Kirov MY
    J Cardiothorac Vasc Anesth; 2017 Feb; 31(1):37-44. PubMed ID: 27554234
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intravascular microdialysis as a method for measuring glucose and lactate during and after cardiac surgery.
    Möller F; Liska J; Eidhagen F; Franco-Cereceda A
    J Diabetes Sci Technol; 2011 Sep; 5(5):1099-107. PubMed ID: 22027302
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients.
    Corstjens AM; Ligtenberg JJ; van der Horst IC; Spanjersberg R; Lind JS; Tulleken JE; Meertens JH; Zijlstra JG
    Crit Care; 2006; 10(5):R135. PubMed ID: 16981981
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Results of a near continuous glucose monitoring technology in surgical intensive care and trauma.
    Nohra E; Buckman S; Bochicchio K; Chamieh J; Reese S; Merrill C; Schuerer D; Bochicchio GV
    Contemp Clin Trials; 2016 Sep; 50():1-4. PubMed ID: 27394384
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients.
    Rijkenberg S; van Steen SC; DeVries JH; van der Voort PHJ
    J Clin Monit Comput; 2018 Oct; 32(5):953-964. PubMed ID: 29218549
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of changes in lactate concentration with intravascular microdialysis during high-risk cardiac surgery using the trend interchangeability method.
    Gouëzel C; Lorne E; Bonnet V; Fradin S; Saplacan V; Gérard JL; Hanouz JL; Fellahi JL; Fischer MO;
    Br J Anaesth; 2017 Dec; 119(6):1110-1117. PubMed ID: 29028910
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous lactate monitoring in critically ill patients using microdialysis.
    Daurat A; Dick M; Louart B; Lefrant JY; Muller L; Roger C
    Anaesth Crit Care Pain Med; 2020 Aug; 39(4):513-517. PubMed ID: 32659456
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluating the clinical accuracy of GlucoMen®Day: a novel microdialysis-based continuous glucose monitor.
    Valgimigli F; Lucarelli F; Scuffi C; Morandi S; Sposato I
    J Diabetes Sci Technol; 2010 Sep; 4(5):1182-92. PubMed ID: 20920438
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous intra-arterial blood glucose monitoring using quenched fluorescence sensing in intensive care patients after cardiac surgery: phase II of a product development study.
    Macken L; Flower OJ; Bird S; Hammond N; Yarad E; Bass F; Fisher C; Strasma P; Finfer S
    Crit Care Resusc; 2015 Sep; 17(3):190-6. PubMed ID: 26282257
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of the intermittently scanned continuous glucose monitoring system in critically ill patients: a prospective, multicenter, observational study.
    Huang W; Li S; Lu J; Shen Y; Wang Y; Wang Y; Feng K; Huang X; Zou Y; Hu L; Lu Y; Zhou J; Li Y
    Endocrine; 2022 Dec; 78(3):470-475. PubMed ID: 36227509
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microdialysis based device for continuous extravascular monitoring of blood glucose.
    Feichtner F; Schaller R; Fercher A; Ratzer M; Ellmerer M; Plank J; Krause B; Pieber T; Schaupp L
    Biomed Microdevices; 2010 Jun; 12(3):399-407. PubMed ID: 20101469
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.