446 related articles for article (PubMed ID: 23298077)
1. Evaluation of an analytic linear Boltzmann transport equation solver for high-density inhomogeneities.
Lloyd SA; Ansbacher W
Med Phys; 2013 Jan; 40(1):011707. PubMed ID: 23298077
[TBL] [Abstract][Full Text] [Related]
2. Clinical implementation and evaluation of the Acuros dose calculation algorithm.
Yan C; Combine AG; Bednarz G; Lalonde RJ; Hu B; Dickens K; Wynn R; Pavord DC; Saiful Huq M
J Appl Clin Med Phys; 2017 Sep; 18(5):195-209. PubMed ID: 28834214
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric evaluation of photon dose calculation under jaw and MLC shielding.
Fogliata A; Clivio A; Vanetti E; Nicolini G; Belosi MF; Cozzi L
Med Phys; 2013 Oct; 40(10):101706. PubMed ID: 24089896
[TBL] [Abstract][Full Text] [Related]
4. Clinical validation of the Acuros XB photon dose calculation algorithm, a grid-based Boltzmann equation solver.
Hoffmann L; Jørgensen MB; Muren LP; Petersen JB
Acta Oncol; 2012 Mar; 51(3):376-85. PubMed ID: 22060134
[TBL] [Abstract][Full Text] [Related]
5. Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc(®) stereotactic treatments.
Fogliata A; Nicolini G; Clivio A; Vanetti E; Cozzi L
Med Phys; 2011 Nov; 38(11):6228-37. PubMed ID: 22047388
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations.
Bush K; Gagne IM; Zavgorodni S; Ansbacher W; Beckham W
Med Phys; 2011 Apr; 38(4):2208-21. PubMed ID: 21626955
[TBL] [Abstract][Full Text] [Related]
7. Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams.
Vassiliev ON; Wareing TA; McGhee J; Failla G; Salehpour MR; Mourtada F
Phys Med Biol; 2010 Feb; 55(3):581-98. PubMed ID: 20057008
[TBL] [Abstract][Full Text] [Related]
8. Phantom Verification of AAA and Acuros Dose Calculations for Lung Cancer: Do Tumor Size and Regression Matter?
Shiraishi S; Fong de Los Santos LE; Antolak JA; Olivier KR; Garces YI; Park SS; Grams MP
Pract Radiat Oncol; 2019 Jan; 9(1):29-37. PubMed ID: 30138746
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media.
Fogliata A; Nicolini G; Clivio A; Vanetti E; Cozzi L
Radiat Oncol; 2011 Jul; 6():82. PubMed ID: 21771317
[TBL] [Abstract][Full Text] [Related]
10. Comparative evaluation of modern dosimetry techniques near low- and high-density heterogeneities.
Alhakeem EA; AlShaikh S; Rosenfeld AB; Zavgorodni SF
J Appl Clin Med Phys; 2015 Sep; 16(5):142–158. PubMed ID: 26699322
[TBL] [Abstract][Full Text] [Related]
11. SU-E-T-529: Dosimetric Evaluation with Heterogeneity in Acuros XB Advanced Dose Calculation Algorithm and Anisotropic Analytical Algorithm (AAA).
Rana S; Rogers K
Med Phys; 2012 Jun; 39(6Part18):3827. PubMed ID: 28518491
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric validation of the Acuros XB Advanced Dose Calculation algorithm: fundamental characterization in water.
Fogliata A; Nicolini G; Clivio A; Vanetti E; Mancosu P; Cozzi L
Phys Med Biol; 2011 Mar; 56(6):1879-904. PubMed ID: 21364257
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the dose calculation accuracy for small fields defined by jaw or MLC for AAA and Acuros XB algorithms.
Fogliata A; Lobefalo F; Reggiori G; Stravato A; Tomatis S; Scorsetti M; Cozzi L
Med Phys; 2016 Oct; 43(10):5685. PubMed ID: 27782735
[TBL] [Abstract][Full Text] [Related]
14. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries.
Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M
Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719
[TBL] [Abstract][Full Text] [Related]
15. On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment.
Fogliata A; Nicolini G; Clivio A; Vanetti E; Cozzi L
Radiat Oncol; 2011 Aug; 6():103. PubMed ID: 21871079
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media.
Han T; Mikell JK; Salehpour M; Mourtada F
Med Phys; 2011 May; 38(5):2651-64. PubMed ID: 21776802
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric comparison of analytical anisotropic algorithm and the two dose reporting modes of Acuros XB dose calculation algorithm in volumetric modulated arc therapy of carcinoma lung and carcinoma prostate.
Gopalakrishnan Z; Bhasi S; P R; Menon SV; B S; Thayil AG; Nair RK
Med Dosim; 2022 Autumn; 47(3):280-287. PubMed ID: 35690544
[TBL] [Abstract][Full Text] [Related]
18. From AAA to Acuros XB-clinical implications of selecting either Acuros XB dose-to-water or dose-to-medium.
Zifodya JM; Challens CH; Hsieh WL
Australas Phys Eng Sci Med; 2016 Jun; 39(2):431-9. PubMed ID: 27008647
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric effects of the acuros XB and anisotropic analytical algorithm on volumetric modulated arc therapy planning for prostate cancer using an endorectal balloon.
Koo T; Chung JB; Eom KY; Seok JY; Kim IA; Kim JS
Radiat Oncol; 2015 Feb; 10():48. PubMed ID: 25890071
[TBL] [Abstract][Full Text] [Related]
20. The accuracy of Acuros XB algorithm for radiation beams traversing a metallic hip implant - comparison with measurements and Monte Carlo calculations.
Ojala J; Kapanen M; Sipilä P; Hyödynmaa S; Pitkänen M
J Appl Clin Med Phys; 2014 Sep; 15(5):4912. PubMed ID: 25207577
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]