These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 23318392)

  • 21. Energy dependence of new thermoluminescent detectors in terms of HP(10) values.
    Miljanić S; Knezević Z; Stuhec M; Ranogajec-Komor M; Krpan K; Vekić B
    Radiat Prot Dosimetry; 2003; 106(3):253-6. PubMed ID: 14690327
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Absorbed dose measurements from a
    D'Arienzo M; Pimpinella M; De Coste V; Capogni M; Ferrari P; Mariotti F; Iaccarino G; Ungania S; Strigari L
    Phys Med; 2020 Jan; 69():127-133. PubMed ID: 31901837
    [TBL] [Abstract][Full Text] [Related]  

  • 23. LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co.
    Nunn AA; Davis SD; Micka JA; DeWerd LA
    Med Phys; 2008 May; 35(5):1859-69. PubMed ID: 18561661
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A technique for calibrating a high dose rate ¹⁹²Ir brachytherapy source.
    Fourie OL; Crabtree TG
    Australas Phys Eng Sci Med; 2012 Mar; 35(1):85-92. PubMed ID: 22187355
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Influence of phantom materials on the energy dependence of LiF:Mg,Ti thermoluminescent dosimeters exposed to 20-300 kV narrow x-ray spectra, 137Cs and 60Co photons.
    Massillon-J L G; Cabrera-Santiago A; Minniti R; O'Brien M; Soares CG
    Phys Med Biol; 2014 Aug; 59(15):4149-66. PubMed ID: 25004055
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Influence of the variation of energy spectra with depth in the dosimetry of 192Ir using LiF TLD.
    Meigooni AS; Meli JA; Nath R
    Phys Med Biol; 1988 Oct; 33(10):1159-70. PubMed ID: 3194446
    [TBL] [Abstract][Full Text] [Related]  

  • 27. On the experimental validation of model-based dose calculation algorithms for
    Pappas EP; Zoros E; Moutsatsos A; Peppa V; Zourari K; Karaiskos P; Papagiannis P
    Phys Med Biol; 2017 May; 62(10):4160-4182. PubMed ID: 28353447
    [TBL] [Abstract][Full Text] [Related]  

  • 28. SU-E-T-137: The Response of TLD-100 in Mixed Fields of Photons and Electrons.
    Lawless M; Junell S; Hammer C; DeWerd L
    Med Phys; 2012 Jun; 39(6Part11):3734. PubMed ID: 28517172
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources.
    Antonovic L; Gustafsson H; Carlsson GA; Carlsson Tedgren A
    Med Phys; 2009 Jun; 36(6):2236-47. PubMed ID: 19610313
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Characterization of nanoDot optically stimulated luminescence detectors and high-sensitivity MCP-N thermoluminescent detectors in the 40-300 kVp energy range.
    Poirier Y; Kuznetsova S; Villarreal-Barajas JE
    Med Phys; 2018 Jan; 45(1):402-413. PubMed ID: 29164632
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The radial depth-dose distribution of a 188W/188Re beta line source measured with novel, ultra-thin TLDs in a PMMA phantom: comparison with Monte Carlo simulations.
    Schaart DR; Bos AJ; Winkelman AJ; Clarijs MC
    Phys Med Biol; 2002 Oct; 47(20):3605-27. PubMed ID: 12433123
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.
    Kim JL; Lee JI; Ji YH; Kim BH; Kim JS; Chang SY
    Radiat Prot Dosimetry; 2006; 119(1-4):353-6. PubMed ID: 16644960
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A study of experimental measurements of dosimetric parameters in HDR IR-192 source.
    Zhang M; Zhang L; Yuan S; Dai G
    Med Dosim; 2010; 35(4):250-4. PubMed ID: 19944591
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In-water calibration of PDR 192Ir brachytherapy sources with an NE2571 ionization chamber.
    Reynaert N; Verhaegen F; Thierens H
    Phys Med Biol; 1998 Aug; 43(8):2095-107. PubMed ID: 9725592
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Variations in photon energy spectra of a 6 MV beam and their impact on TLD response.
    Scarboro SB; Followill DS; Howell RM; Kry SF
    Med Phys; 2011 May; 38(5):2619-28. PubMed ID: 21776799
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Energy correction factors of LiF powder TLDs irradiated in high-energy electron beams and applied to mailed dosimetry for quality assurance networks.
    Marre D; Ferreira IH; Bridier A; Björeland A; Svensson H; Dutreix A; Chavaudra J
    Phys Med Biol; 2000 Dec; 45(12):3657-74. PubMed ID: 11131191
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Photon beam audits for radiation therapy clinics: a pilot mailed dosemeter study in Turkey.
    Yegingil Z; DeWerd LA; Davis SD; Hammer C; Kunugi K
    Radiat Prot Dosimetry; 2012 Jan; 148(2):249-57. PubMed ID: 21362695
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of thermoluminescent dosimeter calibration irradiated in gamma knife and
    Moafi M; Geraily G; Shirazi AR
    J Cancer Res Ther; 2019 Mar; 15(Supplement):S123-S126. PubMed ID: 30900633
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Use of Thermoluminescence Dosimetry for QA in High-Dose-Rate Skin Surface Brachytherapy with Custom-Flap Applicator.
    Manna F; Pugliese M; Buonanno F; Gherardi F; Iannacone E; La Verde G; Muto P; Arrichiello C
    Sensors (Basel); 2023 Mar; 23(7):. PubMed ID: 37050652
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Design of a phantom for the quality control of high dose rate 192Ir source used in brachytherapy.
    Ochoa R; Gómez F; Ferreira IH; Gutt F; de Almeida CE
    Radiother Oncol; 2007 Feb; 82(2):222-8. PubMed ID: 17267060
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.