These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 2332002)

  • 1. Electrophysiologic testing after aortic valve replacement in two patients with aortic stenosis and preoperative ventricular fibrillation.
    Siostrzonek P; Gössinger H; Prischl F; Geissler K; Schneeweiss B; Ciciyasvilli H; Schmoliner R; Mösslacher H
    Eur Heart J; 1990 Apr; 11(4):372-6. PubMed ID: 2332002
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preoperative identification of patients likely to have left ventricular dysfunction after aortic valve replacement. Participants in the Veterans Administration Cooperative Study on Valvular Heart Disease.
    Hwang MH; Hammermeister KE; Oprian C; Henderson W; Bousvaros G; Wong M; Miller DC; Folland E; Sethi G
    Circulation; 1989 Sep; 80(3 Pt 1):I65-76. PubMed ID: 2670330
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemodynamic Consequence of Different Pacing Modes after Aortic Valve Replacement.
    Kiessling AH
    Heart Surg Forum; 2018 Mar; 21(2):E090-E095. PubMed ID: 29658865
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Sudden cardiac death during long-term ECG monitoring of a patient with aortic stenosis].
    Siostrzonek P; Gössinger H; Schmoliner R; Kronik G; Mösslacher H
    Dtsch Med Wochenschr; 1987 Sep; 112(36):1374-6. PubMed ID: 3622282
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival.
    Ali A; Patel A; Ali Z; Abu-Omar Y; Saeed A; Athanasiou T; Pepper J
    J Thorac Cardiovasc Surg; 2011 Aug; 142(2):285-91. PubMed ID: 21272899
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aortic valve replacement in true severe aortic stenosis with low gradient and low ejection fraction.
    Ozsöyler I; Lafci B; Emrecan B; Kestelli M; Bozok S; Ozbek C; Yesil M; Gürbüz A
    Heart Surg Forum; 2006; 9(4):E681-5. PubMed ID: 16757422
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ventricular arrhythmias in aortic valve disease before and after surgery.
    Michel PL; Mandagout O; Vahanian A; Cormier B; Iung B; Luxereau P; Acar J
    J Heart Valve Dis; 1992 Sep; 1(1):72-9. PubMed ID: 1285214
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prediction of paroxysmal atrial fibrillation after aortic valve replacement in patients with aortic stenosis: identification of potential risk factors.
    Orlowska-Baranowska E; Baranowski R; Michalek P; Hoffman P; Rywik T; Rawczylska-Englert I
    J Heart Valve Dis; 2003 Mar; 12(2):136-41. PubMed ID: 12701782
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prognostic value of preoperative atrial fibrillation in patients with aortic stenosis and low ejection fraction having aortic valve replacement.
    Levy F; Garayalde E; Quere JP; Ianetta-Peltier M; Peltier M; Tribouilloy C
    Am J Cardiol; 2006 Sep; 98(6):809-11. PubMed ID: 16950191
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiopulmonary Exercise Testing in Aortic Stenosis.
    Le VDT
    Dan Med J; 2017 May; 64(5):. PubMed ID: 28552098
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Arrhythmia burden in elderly patients with severe aortic stenosis as determined by continuous electrocardiographic recording: toward a better understanding of arrhythmic events after transcatheter aortic valve replacement.
    Urena M; Hayek S; Cheema AN; Serra V; Amat-Santos IJ; Nombela-Franco L; Ribeiro HB; Allende R; Paradis JM; Dumont E; Thourani VH; Babaliaros V; Francisco Pascual J; Cortés C; Del Blanco BG; Philippon F; Lerakis S; Rodés-Cabau J
    Circulation; 2015 Feb; 131(5):469-77. PubMed ID: 25466975
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
    Sharma E; Chu AF
    J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictors of paroxysmal atrial fibrillation in patients undergoing aortic valve replacement.
    Banach M; Goch A; Misztal M; Rysz J; Jaszewski R; Goch JH
    J Thorac Cardiovasc Surg; 2007 Dec; 134(6):1569-76. PubMed ID: 18023685
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Severe prosthesis-patient mismatch after aortic valve replacement for aortic stenosis: Analysis of risk factors for early and long-term mortality.
    Mannacio V; Mannacio L; Mango E; Antignano A; Mottola M; Caparrotti S; Musumeci F; Vosa C
    J Cardiol; 2017 Jan; 69(1):333-339. PubMed ID: 27492659
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical value of regression of electrocardiographic left ventricular hypertrophy after aortic valve replacement.
    Yamabe S; Dohi Y; Higashi A; Kinoshita H; Sada Y; Hidaka T; Kurisu S; Shiode N; Kihara Y;
    Heart Vessels; 2016 Sep; 31(9):1497-503. PubMed ID: 26531830
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis.
    Kato Y; Suehiro S; Shibata T; Sasaki Y; Hirai H
    J Card Surg; 2007; 22(4):314-9. PubMed ID: 17661773
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Arrhythmogenic risk of pulmonary artery catheterisation in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation.
    Bergmann L; Großwendt T; Kahlert P; Konorza T; Wendt D; Thielmann M; Heusch G; Peters J; Kottenberg E
    Anaesthesia; 2013 Jan; 68(1):46-51. PubMed ID: 23121437
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prognostic value of myocardial fibrosis in patients with severe aortic valve stenosis.
    Milano AD; Faggian G; Dodonov M; Golia G; Tomezzoli A; Bortolotti U; Mazzucco A
    J Thorac Cardiovasc Surg; 2012 Oct; 144(4):830-7. PubMed ID: 22244555
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long-term changes in left ventricular mass, chamber size and function after valve replacement in patients with severe aortic stenosis and depressed ejection fraction.
    Pelà G; La Canna G; Metra M; Ceconi C; Berra Centurini P; Alfieri O; Visioli O
    Cardiology; 1997; 88(4):315-22. PubMed ID: 9197424
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study.
    Hong S; Yi G; Youn YN; Lee S; Yoo KJ; Chang BC
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1098-104. PubMed ID: 22959323
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.