These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
254 related articles for article (PubMed ID: 23324061)
21. Establishment and evaluation of a loop-mediated isothermal amplification (LAMP) assay for the semi-quantitative detection of HIV-1 group M virus. Odari EO; Maiyo A; Lwembe R; Gurtler L; Eberle J; Nitschko H J Virol Methods; 2015 Feb; 212():30-8. PubMed ID: 25445795 [TBL] [Abstract][Full Text] [Related]
22. Digital Loop-Mediated Isothermal Amplification on a Commercial Membrane. Lin X; Huang X; Urmann K; Xie X; Hoffmann MR ACS Sens; 2019 Jan; 4(1):242-249. PubMed ID: 30604619 [TBL] [Abstract][Full Text] [Related]
23. STAMP-Based Digital CRISPR-Cas13a for Amplification-Free Quantification of HIV-1 Plasma Viral Loads. Nouri R; Jiang Y; Politza AJ; Liu T; Greene WH; Zhu Y; Nunez JJ; Lian X; Guan W ACS Nano; 2023 Jun; 17(11):10701-10712. PubMed ID: 37252938 [TBL] [Abstract][Full Text] [Related]
24. An assessment of the reproducibility of reverse transcription digital PCR quantification of HIV-1. Falak S; Macdonald R; Busby EJ; O'Sullivan DM; Milavec M; Plauth A; Kammel M; Zeichhardt H; Grunert HP; Kummrow A; Huggett JF Methods; 2022 May; 201():34-40. PubMed ID: 33722693 [TBL] [Abstract][Full Text] [Related]
25. Detection of human Enterovirus 71 reverse transcription loop-mediated isothermal amplification (RT-LAMP). Yaqing H; Wenping Z; Zhiyi Y; Xionghu W; Shouyi Y; Hong Y; Yingchun D; Guifang H Lett Appl Microbiol; 2012 Mar; 54(3):233-9. PubMed ID: 22256968 [TBL] [Abstract][Full Text] [Related]
26. A Novel Approach to the Bioluminescent Detection of the SARS-CoV-2 ORF1ab Gene by Coupling Isothermal RNA Reverse Transcription Amplification with a Digital PCR Approach. Fei Z; Wei R; Cheng C; Xiao P Int J Mol Sci; 2021 Jan; 22(3):. PubMed ID: 33498408 [TBL] [Abstract][Full Text] [Related]
27. Smartphone-Imaged HIV-1 Reverse-Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) on a Chip from Whole Blood. Damhorst GL; Duarte-Guevara C; Chen W; Ghonge T; Cunningham BT; Bashir R Engineering (Beijing); 2015 Sep; 1(3):324-335. PubMed ID: 26705482 [TBL] [Abstract][Full Text] [Related]
28. Instrument for Real-Time Digital Nucleic Acid Amplification on Custom Microfluidic Devices. Selck DA; Ismagilov RF PLoS One; 2016; 11(10):e0163060. PubMed ID: 27760148 [TBL] [Abstract][Full Text] [Related]
29. Real-Time, Digital LAMP with Commercial Microfluidic Chips Reveals the Interplay of Efficiency, Speed, and Background Amplification as a Function of Reaction Temperature and Time. Rolando JC; Jue E; Schoepp NG; Ismagilov RF Anal Chem; 2019 Jan; 91(1):1034-1042. PubMed ID: 30565936 [TBL] [Abstract][Full Text] [Related]
30. Optimizing the performance of digital loop-mediated isothermal amplification. Xue Y; Luo X; Pang X; Zhou J; Wang J Anal Biochem; 2021 Oct; 631():114371. PubMed ID: 34509442 [TBL] [Abstract][Full Text] [Related]
31. Comparative study of sensitivity, linearity, and resistance to inhibition of digital and nondigital polymerase chain reaction and loop mediated isothermal amplification assays for quantification of human cytomegalovirus. Nixon G; Garson JA; Grant P; Nastouli E; Foy CA; Huggett JF Anal Chem; 2014 May; 86(9):4387-94. PubMed ID: 24684191 [TBL] [Abstract][Full Text] [Related]
32. SlipChip Device for Digital Nucleic Acid Amplification. Shen F Methods Mol Biol; 2017; 1547():123-132. PubMed ID: 28044292 [TBL] [Abstract][Full Text] [Related]
33. Parallel multistep digital analysis SlipChip demonstrated with the quantification of nucleic acid by digital LAMP-CRISPR. Yu Z; Xu L; Lyu W; Shen F Lab Chip; 2022 Aug; 22(16):2954-2961. PubMed ID: 35696983 [TBL] [Abstract][Full Text] [Related]
34. Rapid quantitative detection of Human immunodeficiency virus type 1 by a reverse transcription-loop-mediated isothermal amplification assay. Zeng Y; Zhang X; Nie K; Ding X; Ring BZ; Xu L; Dai L; Li X; Ren W; Shi L; Ma X Gene; 2014 May; 541(2):123-8. PubMed ID: 24630968 [TBL] [Abstract][Full Text] [Related]
35. A sensitive in-house RT-PCR genotyping system for combined detection of plasma HIV-1 and assessment of drug resistance. Steegen K; Demecheleer E; De Cabooter N; Nges D; Temmerman M; Ndumbe P; Mandaliya K; Plum J; Verhofstede C J Virol Methods; 2006 May; 133(2):137-45. PubMed ID: 16375980 [TBL] [Abstract][Full Text] [Related]
36. Quantitative analysis of RNA by HPLC and evaluation of RT-dPCR for coronavirus RNA quantification. Niu C; Dong L; Gao Y; Zhang Y; Wang X; Wang J Talanta; 2021 Jun; 228():122227. PubMed ID: 33773731 [TBL] [Abstract][Full Text] [Related]
37. Integrated centrifugal reverse transcriptase loop-mediated isothermal amplification microdevice for influenza A virus detection. Jung JH; Park BH; Oh SJ; Choi G; Seo TS Biosens Bioelectron; 2015 Jun; 68():218-224. PubMed ID: 25569879 [TBL] [Abstract][Full Text] [Related]
38. Evaluation of different RNA extraction methods and storage conditions of dried plasma or blood spots for human immunodeficiency virus type 1 RNA quantification and PCR amplification for drug resistance testing. Monleau M; Montavon C; Laurent C; Segondy M; Montes B; Delaporte E; Boillot F; Peeters M J Clin Microbiol; 2009 Apr; 47(4):1107-18. PubMed ID: 19193835 [TBL] [Abstract][Full Text] [Related]
39. Improved conditions for extraction and amplification of human immunodeficiency virus type 1 RNA from plasma samples with low viral load. Villahermosa ML; Thomson M; Vázquez de Parga E; Cuevas MT; Contreras G; Pérez-Alvarez L; Delgado E; Manjón N; Medrano L; Nájera R J Hum Virol; 2000; 3(1):27-34. PubMed ID: 10774804 [TBL] [Abstract][Full Text] [Related]
40. New design, development, and optimization of an in-house quantitative TaqMan Real-time PCR assay for HIV-1 viral load measurement. Noorbazargan H; Nadji SA; Samiee SM; Paryan M; Mohammadi-Yeganeh S HIV Clin Trials; 2018 Apr; 19(2):61-68. PubMed ID: 29473487 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]