These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
254 related articles for article (PubMed ID: 23324061)
41. [Detecting human respiratory syncytial virus in respiratory samples collected from children with acute respiratory infections by reverse transcription-loop mediated isothermal amplification]. Li F; Zhao LQ; Qian Y; Deng J; Zhu RN; Sun Y; Liu LY Zhonghua Er Ke Za Zhi; 2013 Apr; 51(4):270-5. PubMed ID: 23927800 [TBL] [Abstract][Full Text] [Related]
42. [Visual detection of HIV-1 by reverse transcription loop-mediated isothermal amplification with the hydroxynaphthol blue dye]. Zeng YL; Zhang XG; Nei K; Zhang Y; Yang MJ; Shen HW; Wang J; Shi L; Ma XJ Zhonghua Shi Yan He Lin Chuang Bing Du Xue Za Zhi; 2013 Apr; 27(2):126-8. PubMed ID: 24044219 [TBL] [Abstract][Full Text] [Related]
43. Validation and clinical use of a sensitive HIV-2 viral load assay that uses a whole virus internal control. Styer LM; Miller TT; Parker MM J Clin Virol; 2013 Dec; 58 Suppl 1():e127-33. PubMed ID: 24342472 [TBL] [Abstract][Full Text] [Related]
44. A Rapid, Self-confirming Assay for HIV: Simultaneous Detection of Anti-HIV Antibodies and Viral RNA. Chen Z; Zhu H; Malamud D; Barber C; Ongagna YY; Yasmin R; Modak S; Janal MN; Abrams WR; Montagna RA J AIDS Clin Res; 2016 Jan; 7(1):. PubMed ID: 26925300 [TBL] [Abstract][Full Text] [Related]
46. Development of a One Step Reverse Transcription-Loop-Mediated Isothermal Amplification System for a Highly Sensitive Detection of Rabbit Hepatitis E Virus. Wang J; Zhang H; Yan S; Wang Y; Lu X; Fu H Clin Lab; 2017 May; 63(5):901-905. PubMed ID: 28627822 [TBL] [Abstract][Full Text] [Related]
47. Superiority of Digital Reverse Transcription-PCR (RT-PCR) over Real-Time RT-PCR for Quantitation of Highly Divergent Human Rhinoviruses. Sedlak RH; Nguyen T; Palileo I; Jerome KR; Kuypers J J Clin Microbiol; 2017 Feb; 55(2):442-449. PubMed ID: 27881615 [TBL] [Abstract][Full Text] [Related]
48. A RealTime HIV-1 viral load assay for automated quantitation of HIV-1 RNA in genetically diverse group M subtypes A-H, group O and group N samples. Tang N; Huang S; Salituro J; Mak WB; Cloherty G; Johanson J; Li YH; Schneider G; Robinson J; Hackett J; Swanson P; Abravaya K J Virol Methods; 2007 Dec; 146(1-2):236-45. PubMed ID: 17707519 [TBL] [Abstract][Full Text] [Related]
49. Microfluidic continuous flow digital loop-mediated isothermal amplification (LAMP). Rane TD; Chen L; Zec HC; Wang TH Lab Chip; 2015 Feb; 15(3):776-82. PubMed ID: 25431886 [TBL] [Abstract][Full Text] [Related]
50. Development of a simple and rapid reverse transcription-loop mediated isothermal amplification (RT-LAMP) assay for sensitive detection of Citrus tristeza virus. Warghane A; Misra P; Bhose S; Biswas KK; Sharma AK; Reddy MK; Ghosh DK J Virol Methods; 2017 Dec; 250():6-10. PubMed ID: 28941614 [TBL] [Abstract][Full Text] [Related]
51. An integrated, valveless system for microfluidic purification and reverse transcription-PCR amplification of RNA for detection of infectious agents. Hagan KA; Reedy CR; Uchimoto ML; Basu D; Engel DA; Landers JP Lab Chip; 2011 Mar; 11(5):957-61. PubMed ID: 21152489 [TBL] [Abstract][Full Text] [Related]
52. Evaluation of an affordable HIV-1 virological failure assay and antiretroviral drug resistance genotyping protocol. Bronze M; Aitken SC; Wallis CL; Steegen K; Stuyver LJ; de Wit TF; Stevens W J Virol Methods; 2013 Dec; 194(1-2):300-7. PubMed ID: 23994150 [TBL] [Abstract][Full Text] [Related]
53. Failure to quantify viral load with two of the three commercial methods in a pregnant woman harboring an HIV type 1 subtype G strain. Debyser Z; Van Wijngaerden E; Van Laethem K; Beuselinck K; Reynders M; De Clercq E; Desmyter J; Vandamme AM AIDS Res Hum Retroviruses; 1998 Mar; 14(5):453-9. PubMed ID: 9546805 [TBL] [Abstract][Full Text] [Related]
55. A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or whole blood. Curtis KA; Morrison D; Rudolph DL; Shankar A; Bloomfield LSP; Switzer WM; Owen SM J Virol Methods; 2018 May; 255():91-97. PubMed ID: 29474813 [TBL] [Abstract][Full Text] [Related]
56. Highly sensitive methods based on seminested real-time reverse transcription-PCR for quantitation of human immunodeficiency virus type 1 unspliced and multiply spliced RNA and proviral DNA. Pasternak AO; Adema KW; Bakker M; Jurriaans S; Berkhout B; Cornelissen M; Lukashov VV J Clin Microbiol; 2008 Jul; 46(7):2206-11. PubMed ID: 18463204 [TBL] [Abstract][Full Text] [Related]
57. Quantitative assessment of the sensitivity of various commercial reverse transcriptases based on armored HIV RNA. Okello JB; Rodriguez L; Poinar D; Bos K; Okwi AL; Bimenya GS; Sewankambo NK; Henry KR; Kuch M; Poinar HN PLoS One; 2010 Nov; 5(11):e13931. PubMed ID: 21085668 [TBL] [Abstract][Full Text] [Related]
58. HIV-1 viral load and phenotypic antiretroviral drug resistance assays based on reverse transcriptase activity in comparison to amplification based HIV-1 RNA and genotypic assays. Napravnik S; Cachafeiro A; Stewart P; Eron JJ; Fiscus SA J Clin Virol; 2010 Jan; 47(1):18-22. PubMed ID: 19896416 [TBL] [Abstract][Full Text] [Related]
59. Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs. Tan YL; Huang AQ; Tang LJ; Jiang JH Chem Sci; 2021 May; 12(24):8445-8451. PubMed ID: 34221326 [TBL] [Abstract][Full Text] [Related]
60. Development of a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a highly sensitive detection of enterovirus in the stool samples of acute flaccid paralysis cases. Arita M; Ling H; Yan D; Nishimura Y; Yoshida H; Wakita T; Shimizu H BMC Infect Dis; 2009 Dec; 9():208. PubMed ID: 20015403 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]