201 related articles for article (PubMed ID: 23326186)
1. Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery.
Shousha SM; Abo Steit MA; Hosny MH; Ewais WA; Shalaby AM
Clin Ophthalmol; 2013; 7():71-9. PubMed ID: 23326186
[TBL] [Abstract][Full Text] [Related]
2. Measurement of intraocular pressure in LASIK and LASEK patients using the Reichert Ocular Response Analyzer and Goldmann applanation tonometry.
Kirwan C; O'Keefe M
J Refract Surg; 2008 Apr; 24(4):366-70. PubMed ID: 18500086
[TBL] [Abstract][Full Text] [Related]
3. Effectiveness of the Goldmann Applanation Tonometer, the Dynamic Contour Tonometer, the Ocular Response Analyzer and the Corvis ST in Measuring Intraocular Pressure following FS-LASIK.
Bao F; Huang W; Zhu R; Lu N; Wang Y; Li H; Wu S; Lin H; Wang J; Zheng X; Huang J; Li Y; Wang Q; Elsheikh A
Curr Eye Res; 2020 Feb; 45(2):144-152. PubMed ID: 31869261
[No Abstract] [Full Text] [Related]
4. Changes in biomechanical properties of the cornea and intraocular pressure after myopic laser in situ keratomileusis using a femtosecond laser for flap creation determined using ocular response analyzer and Goldmann applanation tonometry.
Shin J; Kim TW; Park SJ; Yoon M; Lee JW
J Glaucoma; 2015 Mar; 24(3):195-201. PubMed ID: 23807345
[TBL] [Abstract][Full Text] [Related]
5. Refinement of Intraocular Pressure Measurements made by Ocular Response Analyzer following Laser in Situ Keratomileusis using M2 90 Moria Microkeratome for Egyptian Myopic and Astigmatic Patients.
Refai TA; Hassanin OA
Electron Physician; 2016 Dec; 8(12):3429-3433. PubMed ID: 28163860
[TBL] [Abstract][Full Text] [Related]
6. Pressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.
Shemesh G; Man O; Michaeli A; Varssano D; Lazar M
J Refract Surg; 2007 Apr; 23(4):405-9. PubMed ID: 17455836
[TBL] [Abstract][Full Text] [Related]
7. Changes in corneal biomechanics and intraocular pressure following Femto-LASIK using Goldman applanation tonometry and ocular response analyzer.
Hemida AY; Said OM; Abdel-Meguid AAE; Iqbal M; Badawi AE
Int J Ophthalmol; 2020; 13(5):782-787. PubMed ID: 32420226
[TBL] [Abstract][Full Text] [Related]
8. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry.
Pepose JS; Feigenbaum SK; Qazi MA; Sanderson JP; Roberts CJ
Am J Ophthalmol; 2007 Jan; 143(1):39-47. PubMed ID: 17188041
[TBL] [Abstract][Full Text] [Related]
9. Comparison between different tonometers following intrastromal corneal ring segments implantation.
Elfwwal MM; Elbasty MK; Khattab MF; ElShazly MI
Eur J Ophthalmol; 2022 Jan; 32(1):43-49. PubMed ID: 34472983
[TBL] [Abstract][Full Text] [Related]
10. Goldmann and modified Goldmann tonometry measuring intraocular pressure changes in eyes which underwent myopic laser in situ Keratomileusis and photorefractive keratectomy.
Ang RET; Rixon A; Kilgore K; Schweitzer J
BMC Ophthalmol; 2022 Dec; 22(1):503. PubMed ID: 36539706
[TBL] [Abstract][Full Text] [Related]
11. Intraocular Pressure Based on Dynamic Bidirectional Applanation and Air-puff Tonometry: A Comparative Study.
Kilavuzoglu AEB; Cosar CB; Celebi AR; Al Parmak UE
J Curr Glaucoma Pract; 2019; 13(2):68-73. PubMed ID: 31564796
[TBL] [Abstract][Full Text] [Related]
12. Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA.
Iglesias M; Kudsieh B; Laiseca A; Santos C; Nadal J; Barraquer R; Casaroli-Marano RP
BMC Ophthalmol; 2022 Feb; 22(1):79. PubMed ID: 35168601
[TBL] [Abstract][Full Text] [Related]
13. Effect of mild to moderate myopic correction by laser-assisted in situ keratomileusis on intraocular pressure measurements with goldmann applanation tonometer, tono-pen, and pneumatonometer.
Vakili R; Choudhri SA; Tauber S; Shields MB
J Glaucoma; 2002 Dec; 11(6):493-6. PubMed ID: 12483093
[TBL] [Abstract][Full Text] [Related]
14. Intraocular Pressure Changes in Myopic Patients Undergoing Laser In-Situ Keratomileusis and Photorefractive Keratectomy.
Humayun S; Bangash YW; Ishaq M; Shah AA
J Coll Physicians Surg Pak; 2023 Oct; 33(10):1148-1152. PubMed ID: 37804021
[TBL] [Abstract][Full Text] [Related]
15. Assessment of intraocular pressure measured by Reichert Ocular Response Analyzer, Goldmann Applanation Tonometry, and Dynamic Contour Tonometry in healthy individuals.
Ouyang PB; Li CY; Zhu XH; Duan XC
Int J Ophthalmol; 2012; 5(1):102-7. PubMed ID: 22553765
[TBL] [Abstract][Full Text] [Related]
16. Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis.
El Danasoury MA; El Maghraby A; Coorpender SJ
J Refract Surg; 2001; 17(2):97-104. PubMed ID: 11310772
[TBL] [Abstract][Full Text] [Related]
17. Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis.
Helmy H; Hashem O
Clin Ophthalmol; 2020; 14():509-516. PubMed ID: 32109987
[TBL] [Abstract][Full Text] [Related]
18. Comparison of intraocular pressure measured by ocular response analyzer and Goldmann applanation tonometer after corneal refractive surgery: a systematic review and meta-analysis.
Zhang H; Sun Z; Li L; Sun R; Zhang H
BMC Ophthalmol; 2020 Jan; 20(1):23. PubMed ID: 31924174
[TBL] [Abstract][Full Text] [Related]
19. Corvis ST Tonometer for Measuring Postoperative IOP in LASIK Patients.
Hong J; Yu Z; Jiang C; Zhou X; Liu Z; Sun X; Xu J
Optom Vis Sci; 2015 May; 92(5):589-95. PubMed ID: 25871871
[TBL] [Abstract][Full Text] [Related]
20. Changes in intraocular pressure after laser in situ keratomileusis.
Rashad KM; Bahnassy AA
J Refract Surg; 2001; 17(4):420-7. PubMed ID: 11471999
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]