These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

602 related articles for article (PubMed ID: 23333140)

  • 1. Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic CoreValve Revalving system devices: a multicenter collaborative study: the PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration).
    Chieffo A; Buchanan GL; Van Mieghem NM; Tchetche D; Dumonteil N; Latib A; van der Boon RM; Vahdat O; Marcheix B; Farah B; Serruys PW; Fajadet J; Carrié D; de Jaegere PP; Colombo A
    J Am Coll Cardiol; 2013 Feb; 61(8):830-6. PubMed ID: 23333140
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Propensity-matched comparison between Direct Flow Medical, Medtronic Corevalve, and Edwards Sapien XT prostheses: Device success, thirty-day safety, and mortality.
    Zhang Y; Pyxaras SA; Wolf A; Schmitz T; Naber CK
    Catheter Cardiovasc Interv; 2015 Jun; 85(7):1217-25. PubMed ID: 25581785
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Outcomes after transcatheter aortic valve implantation with both Edwards-SAPIEN and CoreValve devices in a single center: the Milan experience.
    Godino C; Maisano F; Montorfano M; Latib A; Chieffo A; Michev I; Al-Lamee R; Bande M; Mussardo M; Arioli F; Ielasi A; Cioni M; Taramasso M; Arendar I; Grimaldi A; Spagnolo P; Zangrillo A; La Canna G; Alfieri O; Colombo A
    JACC Cardiovasc Interv; 2010 Nov; 3(11):1110-21. PubMed ID: 21087745
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic regurgitation after transcatheter aortic valve implantation with balloon- and self-expandable prostheses: a pooled analysis from a 2-center experience.
    Abdel-Wahab M; Comberg T; Büttner HJ; El-Mawardy M; Chatani K; Gick M; Geist V; Richardt G; Neumann FJ;
    JACC Cardiovasc Interv; 2014 Mar; 7(3):284-92. PubMed ID: 24650401
    [TBL] [Abstract][Full Text] [Related]  

  • 5. European experience with the second-generation Edwards SAPIEN XT transcatheter heart valve in patients with severe aortic stenosis: 1-year outcomes from the SOURCE XT Registry.
    Schymik G; Lefèvre T; Bartorelli AL; Rubino P; Treede H; Walther T; Baumgartner H; Windecker S; Wendler O; Urban P; Mandinov L; Thomas M; Vahanian A
    JACC Cardiovasc Interv; 2015 Apr; 8(5):657-69. PubMed ID: 25946437
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of preoperative chronic kidney disease on short- and long-term outcomes after transcatheter aortic valve implantation: a Pooled-RotterdAm-Milano-Toulouse In Collaboration Plus (PRAGMATIC-Plus) initiative substudy.
    Dumonteil N; van der Boon RM; Tchetche D; Chieffo A; Van Mieghem NM; Marcheix B; Buchanan GL; Vahdat O; Serruys PW; Fajadet J; Colombo A; de Jaegere PP; Carrié D
    Am Heart J; 2013 May; 165(5):752-60. PubMed ID: 23622912
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Periprocedural and short-term outcomes of transfemoral transcatheter aortic valve implantation with the Sapien XT as compared with the Edwards Sapien valve.
    Mussardo M; Latib A; Chieffo A; Godino C; Ielasi A; Cioni M; Takagi K; Davidavicius G; Montorfano M; Maisano F; Carlino M; Franco A; Covello RD; Spagnolo P; Grimaldi A; Alfieri O; Colombo A
    JACC Cardiovasc Interv; 2011 Jul; 4(7):743-50. PubMed ID: 21777881
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predictors and outcomes after transcatheter aortic valve implantation using different approaches according to the valve academic research consortium definitions.
    Seiffert M; Schnabel R; Conradi L; Diemert P; Schirmer J; Koschyk D; Linder M; Kersten JF; Grosser A; Wilde S; Blankenberg S; Reichenspurner H; Baldus S; Treede H
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):640-52. PubMed ID: 23172652
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.
    Kaya D; Tanriverdi Z; Dursun H; Colluoglu T
    Int J Cardiovasc Imaging; 2016 Sep; 32(9):1371-1378. PubMed ID: 27278270
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transfemoral aortic valve implantation in patients with an annulus dimension suitable for either the Edwards valve or the CoreValve.
    Watanabe Y; Hayashida K; Yamamoto M; Mouillet G; Chevalier B; Oguri A; Dubois-Rande JL; Morice MC; Teiger E; Lefèvre T
    Am J Cardiol; 2013 Sep; 112(5):707-13. PubMed ID: 23751936
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transapical versus transfemoral aortic valve implantation: a multicenter collaborative study.
    van der Boon RM; Marcheix B; Tchetche D; Chieffo A; Van Mieghem NM; Dumonteil N; Vahdat O; Maisano F; Serruys PW; Kappetein AP; Fajadet J; Colombo A; Carrié D; van Domburg RT; de Jaegere PP
    Ann Thorac Surg; 2014 Jan; 97(1):22-8. PubMed ID: 24263012
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries.
    Ihlberg L; Nissen H; Nielsen NE; Rück A; Busund R; Klaarborg KE; Soendergaard L; Harnek J; Miettinen H; Eskola M; Wahba A; Laine M
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1047-54; discussion 1054. PubMed ID: 23998786
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis.
    Jatene T; Castro-Filho A; Meneguz-Moreno RA; Siqueira DA; Abizaid AAC; Ramos AIO; Arrais M; Le Bihan DCS; Barretto RBM; Moreira AC; Sousa AGMR; Eduardo Sousa J
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):139-146. PubMed ID: 28029207
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies.
    Généreux P; Head SJ; Van Mieghem NM; Kodali S; Kirtane AJ; Xu K; Smith C; Serruys PW; Kappetein AP; Leon MB
    J Am Coll Cardiol; 2012 Jun; 59(25):2317-26. PubMed ID: 22503058
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The role of sex on VARC outcomes following transcatheter aortic valve implantation with both Edwards SAPIEN™ and Medtronic CoreValve ReValving System® devices: the Milan registry.
    Buchanan GL; Chieffo A; Montorfano M; Maisano F; Latib A; Godino C; Cioni M; Gullace MA; Franco A; Gerli C; Alfieri O; Colombo A
    EuroIntervention; 2011 Sep; 7(5):556-63. PubMed ID: 21930459
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incidence, predictors and impact of bleeding after transcatheter aortic valve implantation using the balloon-expandable Edwards prosthesis.
    Borz B; Durand E; Godin M; Tron C; Canville A; Litzler PY; Bessou JP; Cribier A; Eltchaninoff H
    Heart; 2013 Jun; 99(12):860-5. PubMed ID: 23236027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of severe left ventricular systolic dysfunction on hospital outcome after transcatheter aortic valve implantation or surgical aortic valve replacement: results from a propensity-matched population of the Italian OBSERVANT multicenter study.
    Onorati F; D'Errigo P; Grossi C; Barbanti M; Ranucci M; Covello DR; Rosato S; Maraschini A; Santoro G; Tamburino C; Seccareccia F; Santini F; Menicanti L;
    J Thorac Cardiovasc Surg; 2014 Feb; 147(2):568-75. PubMed ID: 24263007
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the CoreValve versus the Edwards valve.
    Franzoni I; Latib A; Maisano F; Costopoulos C; Testa L; Figini F; Giannini F; Basavarajaiah S; Mussardo M; Slavich M; Taramasso M; Cioni M; Longoni M; Ferrarello S; Radinovic A; Sala S; Ajello S; Sticchi A; Giglio M; Agricola E; Chieffo A; Montorfano M; Alfieri O; Colombo A
    Am J Cardiol; 2013 Aug; 112(4):554-9. PubMed ID: 23726173
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sex-related differences in outcomes after transcatheter or surgical aortic valve replacement in patients with severe aortic stenosis: Insights from the PARTNER Trial (Placement of Aortic Transcatheter Valve).
    Williams M; Kodali SK; Hahn RT; Humphries KH; Nkomo VT; Cohen DJ; Douglas PS; Mack M; McAndrew TC; Svensson L; Thourani VH; Tuzcu EM; Weissman NJ; Kirtane AJ; Leon MB
    J Am Coll Cardiol; 2014 Apr; 63(15):1522-8. PubMed ID: 24561149
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two-year outcomes for patients with severe symptomatic aortic stenosis treated with transcatheter aortic valve implantation.
    Codner P; Assali A; Dvir D; Vaknin-Assa H; Porat E; Shapira Y; Kupershmidt M; Bental T; Battler A; Sagie A; Kornowski R
    Am J Cardiol; 2013 May; 111(9):1330-6. PubMed ID: 23415022
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.