These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 23359099)

  • 1. Biomechanical testing of a new plate system for the distal humerus compared to two well-established implants.
    Voigt C; Rank C; Waizner K; Wendlandt R; Unger A; Schulz AP; Jürgens C; Renken F
    Int Orthop; 2013 Apr; 37(4):667-72. PubMed ID: 23359099
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities.
    Schuster I; Korner J; Arzdorf M; Schwieger K; Diederichs G; Linke B
    J Orthop Trauma; 2008 Feb; 22(2):113-20. PubMed ID: 18349779
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.
    Korner J; Diederichs G; Arzdorf M; Lill H; Josten C; Schneider E; Linke B
    J Orthop Trauma; 2004; 18(5):286-93. PubMed ID: 15105750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.
    Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ
    Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
    Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
    Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calcar screw position in proximal humerus fracture fixation: Don't miss high!
    Mehta S; Chin M; Sanville J; Namdari S; Hast MW
    Injury; 2018 Mar; 49(3):624-629. PubMed ID: 29452734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability?
    Ahmad M; Nanda R; Bajwa AS; Candal-Couto J; Green S; Hui AC
    Injury; 2007 Mar; 38(3):358-64. PubMed ID: 17296199
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical Design Optimization of Distal Humerus Fracture Plates: A Review.
    Zdero R; Brzozowski P; Schemitsch EH
    Biomed Res Int; 2024; 2024():6015794. PubMed ID: 38966093
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Biomechanical comparative study of three types of osteosynthesis in the treatment of supra and intercondylar fractures of the humerus in adults].
    Fornasiéri C; Staub C; Tourné Y; Rumelhart C; Saragaglia D
    Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(3):237-42. PubMed ID: 9255359
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures.
    Wagner FC; Neumann MV; Wolf S; Jonaszik A; Izadpanah K; Piatek S; Südkamp NP
    Injury; 2020 Jun; 51(6):1281-1287. PubMed ID: 32197829
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures.
    Jabran A; Peach C; Zou Z; Ren L
    Proc Inst Mech Eng H; 2019 Mar; 233(3):372-382. PubMed ID: 30700217
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Screws with larger core diameter and lower thread pitch increase the stability of locked plating in osteoporotic proximal humeral fractures.
    Schliemann B; Risse N; Frank A; Müller M; Michel P; Raschke MJ; Katthagen JC
    Clin Biomech (Bristol, Avon); 2019 Mar; 63():21-26. PubMed ID: 30784787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical analysis of a novel Y-plate designed for the treatment of extraarticular distal humerus fractures.
    Adamović P; Kalajžić L; Hrman D; Kodvanj J; Sabalić S
    Injury; 2023 Jul; 54(7):110840. PubMed ID: 37230827
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone.
    O'Toole RV; Andersen RC; Vesnovsky O; Alexander M; Topoleski LD; Nascone JW; Sciadini MF; Turen C; Eglseder WA
    J Orthop Trauma; 2008; 22(10):709-15. PubMed ID: 18978547
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Schuhli augmentation of plate and screw fixation for humeral shaft fractures: a laboratory study.
    Simon JA; Dennis MG; Kummer FJ; Koval KJ
    J Orthop Trauma; 1999; 13(3):196-9. PubMed ID: 10206251
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical evaluation of a transcondylar screw from the dorsolateral plate support on the stabilization of orthogonal plate configuration in distal humeral fracture.
    Hara A; Kudo T; Ichihara S; Iwase H; Nagao M; Maruyama Y; Kaneko K
    Injury; 2019 Feb; 50(2):256-262. PubMed ID: 30579588
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.
    Kudo T; Hara A; Iwase H; Ichihara S; Nagao M; Maruyama Y; Kaneko K
    Injury; 2016 Oct; 47(10):2071-2076. PubMed ID: 27578052
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants.
    Scolaro JA; Hsu JE; Svach DJ; Mehta S
    Injury; 2014 Dec; 45(12):2040-4. PubMed ID: 25249244
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical evaluation of the fixation methods for transcondylar fracture of the humerus:ONI plate versus conventional plates and screws.
    Shimamura Y; Nishida K; Imatani J; Noda T; Hashizume H; Ohtsuka A; Ozaki T
    Acta Med Okayama; 2010 Apr; 64(2):115-20. PubMed ID: 20424666
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures.
    Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H
    Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):735-41. PubMed ID: 24997810
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.