These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 23365852)

  • 1. Stroke volume obtained from the brachial artery using transbrachial electrical bioimpedance velocimetry.
    Henry IC; Bernstein DP; Banet MJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():142-5. PubMed ID: 23365852
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of stroke volume and cardiac output by electrical interrogation of the brachial artery in normals: assessment of strengths, limitations, and sources of error.
    Bernstein DP; Henry IC; Lemmens HJ; Chaltas JL; DeMaria AN; Moon JB; Kahn AM
    J Clin Monit Comput; 2015 Dec; 29(6):789-800. PubMed ID: 25682204
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stroke volume obtained by electrical interrogation of the brachial artery: transbrachial electrical bioimpedance velocimetry.
    Bernstein DP; Henry IC; Banet MJ; Dittrich T
    Physiol Meas; 2012 Apr; 33(4):629-49. PubMed ID: 22442159
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Non-invasive versus invasive cardiovascular monitoring. Determination of stroke volume and pulmonary hydration using a new bioimpedance monitor].
    Boldt J; Kling D; Thiel A; Hempelmann G
    Anaesthesist; 1988 Apr; 37(4):218-23. PubMed ID: 3261552
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of changes in cardiac output from the electrical impedance waveform in the forearm.
    Wang JJ; Wang PW; Liu CP; Lin SK; Hu WC; Kao T
    Physiol Meas; 2007 Sep; 28(9):989-99. PubMed ID: 17827648
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relationship between bioimpedance, thermodilution, and ventriculographic measurements in experimental congestive heart failure.
    Spinale FG; Hendrick DA; Crawford FA; Carabello BA
    Cardiovasc Res; 1990 May; 24(5):423-9. PubMed ID: 2372797
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stroke volume measurement by impedance cardiography using a formula based on the delta z waveform.
    Granerus G; Elg R
    Clin Phys Physiol Meas; 1982 May; 3(2):131-9. PubMed ID: 6126290
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous non-invasive measurement of stroke volume and cardiac index in infants and children: comparison of Impedance Cardiography NICaS® vs CardioQ® method.
    Beck R; Milella L; Labellarte C
    Clin Ter; 2018; 169(3):e110-e113. PubMed ID: 29938742
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stroke volume estimation in heart failure patients using bioimpedance: a realistic simulation of the forward problem.
    Sokolovsky RE; Zlochiver S; Abboud S
    Physiol Meas; 2008 Jun; 29(6):S139-49. PubMed ID: 18544809
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output.
    Trinkmann F; Berger M; Doesch C; Papavassiliu T; Schoenberg SO; Borggrefe M; Kaden JJ; Saur J
    J Clin Monit Comput; 2016 Aug; 30(4):399-408. PubMed ID: 26115774
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review.
    Newman DG; Callister R
    Aviat Space Environ Med; 1999 Aug; 70(8):780-9. PubMed ID: 10447052
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography.
    Marik PE; Pendelton JE; Smith R
    Crit Care Med; 1997 Sep; 25(9):1545-50. PubMed ID: 9295830
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transthoracic impedance cardiography: a noninvasive method of hemodynamic assessment.
    Bayram M; Yancy CW
    Heart Fail Clin; 2009 Apr; 5(2):161-8. PubMed ID: 19249685
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiac performance measured by impedance cardiography and radionuclide angiography.
    Pedersen T
    Methods Find Exp Clin Pharmacol; 1984 Nov; 6(11):717-20. PubMed ID: 6530910
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure.
    Albert NM; Hail MD; Li J; Young JB
    Am J Crit Care; 2004 Nov; 13(6):469-79. PubMed ID: 15568652
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography.
    Gonzalez-Represas A; Mourot L
    Int J Cardiovasc Imaging; 2020 Mar; 36(3):447-455. PubMed ID: 31845049
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Mechano- and impedance cardiography parameters in patients with heart failure in administration of a calcium antagonist. The significance of the Heather index].
    Linde M; Ohnhaus EE; Kirch W
    Z Kardiol; 1989 Mar; 78(3):181-6. PubMed ID: 2652906
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications.
    Moshkovitz Y; Kaluski E; Milo O; Vered Z; Cotter G
    Curr Opin Cardiol; 2004 May; 19(3):229-37. PubMed ID: 15096956
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hypertonic-hyperoncotic solutions improve cardiac function in children after open-heart surgery.
    Schroth M; Plank C; Meissner U; Eberle KP; Weyand M; Cesnjevar R; Dötsch J; Rascher W
    Pediatrics; 2006 Jul; 118(1):e76-84. PubMed ID: 16751617
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Haemodynamic changes during craniotomy monitored by a bioimpedance plethysmographic noninvasive cardiac output monitor.
    Ali Z; Umamaheswara Rao GS; Jaganath A
    J Clin Monit Comput; 2009 Jun; 23(3):157-61. PubMed ID: 19205908
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.