These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
109 related articles for article (PubMed ID: 23366049)
1. A stiffness probe based on force and vision sensing for soft tissue diagnosis. Li J; Liu H; Althoefer K; Seneviratne LD Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():944-7. PubMed ID: 23366049 [TBL] [Abstract][Full Text] [Related]
2. Air-float palpation probe for tissue abnormality identification during minimally invasive surgery. Wanninayake IB; Dasgupta P; Seneviratne LD; Althoefer K IEEE Trans Biomed Eng; 2013 Oct; 60(10):2735-44. PubMed ID: 23708764 [TBL] [Abstract][Full Text] [Related]
3. An indentation depth-force sensing wheeled probe for abnormality identification during minimally invasive surgery. Liu H; Puangmali P; Zbyszewski D; Elhage O; Dasgupta P; Dai JS; Seneviratne L; Althoefer K Proc Inst Mech Eng H; 2010; 224(6):751-63. PubMed ID: 20608492 [TBL] [Abstract][Full Text] [Related]
4. Finite-element modeling of soft tissue rolling indentation. Sangpradit K; Liu H; Dasgupta P; Althoefer K; Seneviratne LD IEEE Trans Biomed Eng; 2011 Dec; 58(12):3319-27. PubMed ID: 21257372 [TBL] [Abstract][Full Text] [Related]
5. Rolling mechanical imaging for tissue abnormality localization during minimally invasive surgery. Liu H; Noonan DP; Challacombe BJ; Dasgupta P; Seneviratne LD; Althoefer K IEEE Trans Biomed Eng; 2010 Feb; 57(2):404-14. PubMed ID: 19789104 [TBL] [Abstract][Full Text] [Related]
6. Contact angle and indentation velocity dependency for a resonance sensor--evaluation on soft tissue silicone models. Astrand AP; Jalkanen V; Andersson BM; Lindahl OA J Med Eng Technol; 2013 Apr; 37(3):185-96. PubMed ID: 23547792 [TBL] [Abstract][Full Text] [Related]
7. Air-cushion force-sensitive probe for soft tissue investigation during minimally invasive surgery. Zbyszewski D; Challacombe B; Liu H; Seneviratne L; Dasgupta P; Murphy D; Althoefer K J Endourol; 2009 Sep; 23(9):1421-4. PubMed ID: 19694518 [TBL] [Abstract][Full Text] [Related]
8. Vision-Based Contact Adhesion Measurement Method on Soft Matter Surfaces. Lu S; Zhu H; Song L; Zheng Y; Fang F Langmuir; 2023 Aug; 39(30):10432-10444. PubMed ID: 37460243 [TBL] [Abstract][Full Text] [Related]
9. An optical coherence tomography (OCT)-based air jet indentation system for measuring the mechanical properties of soft tissues. Huang YP; Zheng YP; Wang SZ; Chen ZP; Huang QH; He YH Meas Sci Technol; 2009 Jan; 20(1):1-11. PubMed ID: 20463843 [TBL] [Abstract][Full Text] [Related]
10. Wheel/tissue force interaction: a new concept for soft tissue diagnosis during MIS. Zbyszewski D; Liu H; Puangmali P; Althoefer K; Nunes CS; Seneviratne LD; Challacombe B; Murphy D; Dasgupta P Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5556-9. PubMed ID: 19163976 [TBL] [Abstract][Full Text] [Related]
11. A comparative study between an improved novel air-cushion sensor and a wheeled probe for minimally invasive surgery. Zbyszewski D; Challacombe B; Li J; Seneviratne L; Althoefer K; Dasgupta P; Murphy D J Endourol; 2010 Jul; 24(7):1155-9. PubMed ID: 20624084 [TBL] [Abstract][Full Text] [Related]
12. Palpation force modulation strategies to identify hard regions in soft tissue organs. Konstantinova J; Cotugno G; Dasgupta P; Althoefer K; Nanayakkara T PLoS One; 2017; 12(2):e0171706. PubMed ID: 28199349 [TBL] [Abstract][Full Text] [Related]
13. A novel palpation-based method for tumor nodule quantification in soft tissue-computational framework and experimental validation. Palacio-Torralba J; Reuben RL; Chen Y Med Biol Eng Comput; 2020 Jun; 58(6):1369-1381. PubMed ID: 32279204 [TBL] [Abstract][Full Text] [Related]
14. Minimum indentation depth for characterization of 2nd sub-metatarsal head and heel pad tissue properties. Chin Teoh J; Bena Lim Y; Lee T J Biomech; 2015 Jul; 48(10):2096-101. PubMed ID: 25890816 [TBL] [Abstract][Full Text] [Related]