BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 23366642)

  • 1. Effect of arching spine on deformation of the ligamentum flavum during epidural needle insertion.
    Naemura K
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():3344-7. PubMed ID: 23366642
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of tissue properties in epidural needle insertion on human specimen and synthetic materials.
    Esterer B; Hollensteiner M; Schrempf A; Winkler M; Gabauer S; Fürst D; Merwa R; Panzer S; Püschel K; Augat P
    J Mech Behav Biomed Mater; 2020 Oct; 110():103946. PubMed ID: 32957238
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical analysis for the epidural needle insertion.
    Furuya K; Naemura K; Nagai K; Okubo N; Saito H
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6699-702. PubMed ID: 24111280
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Young's modulus measurement of the porcine ligamentum flavum for evaluating the deformation during epidural insertion.
    Naemura K
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3923-5. PubMed ID: 21097084
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new technique to assist epidural needle placement: fiberoptic-guided insertion using two wavelengths.
    Ting CK; Tsou MY; Chen PT; Chang KY; Mandell MS; Chan KH; Chang Y
    Anesthesiology; 2010 May; 112(5):1128-35. PubMed ID: 20418693
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The incidence of lumbar ligamentum flavum midline gaps.
    Lirk P; Moriggl B; Colvin J; Keller C; Kirchmair L; Rieder J; Kolbitsch C
    Anesth Analg; 2004 Apr; 98(4):1178-1180. PubMed ID: 15041621
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Incidence of lower thoracic ligamentum flavum midline gaps.
    Lirk P; Colvin J; Steger B; Colvin HP; Keller C; Rieder J; Kolbitsch C; Moriggl B
    Br J Anaesth; 2005 Jun; 94(6):852-5. PubMed ID: 15817710
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Morphometric studies of the ligamentum flavum: a correlative microanatomical and MRI study of the lumbar spine.
    Winkler PA; Zausinger S; Milz S; Buettner A; Wiesmann M; Tonn JC
    Zentralbl Neurochir; 2007 Nov; 68(4):200-4. PubMed ID: 17963193
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Lumbar Ligamentum Flavum Does Not Have Two Layers and Is Confluent with the Interspinous Ligament: Anatomical Study with Application to Surgical and Interventional Pain Procedures.
    Iwanaga J; Ishak B; Saga T; Singla A; Impastato D; Chapman JR; Oskouian RJ; David G; Porzionato A; Reina MA; Macchi V; de Caro R; Tubbs RS
    Clin Anat; 2020 Jan; 33(1):34-40. PubMed ID: 31325341
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Discriminant analysis for anaesthetic decision-making: an intelligent recognition system for epidural needle insertion.
    Lin SP; Mandell MS; Chang Y; Chen PT; Tsou MY; Chan KH; Ting CK
    Br J Anaesth; 2012 Feb; 108(2):302-7. PubMed ID: 22157847
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cervical and high thoracic ligamentum flavum frequently fails to fuse in the midline.
    Lirk P; Kolbitsch C; Putz G; Colvin J; Colvin HP; Lorenz I; Keller C; Kirchmair L; Rieder J; Moriggl B
    Anesthesiology; 2003 Dec; 99(6):1387-90. PubMed ID: 14639154
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anatomical analysis of the human ligamentum flavum in the thoracic spine: Clinical implications for posterior thoracic spinal surgery.
    Ahmadi SA; Suzuki A; Terai H; Tamai K; Akhgar J; Hoshino M; Toyoda H; Rahmani MS; Hayashi K; Ohyama S; Takahashi S; Nakamura H
    J Orthop Sci; 2019 Jan; 24(1):62-67. PubMed ID: 30279134
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sonoanatomy of the lumbar spine in patients with previous unintentional dural punctures during labor epidurals.
    Lee Y; Tanaka M; Carvalho JC
    Reg Anesth Pain Med; 2008; 33(3):266-70. PubMed ID: 18433679
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ligamentum flavum hypertrophy in asymptomatic and chronic low back pain subjects.
    Munns JJ; Lee JY; Espinoza Orías AA; Takatori R; Andersson GB; An HS; Inoue N
    PLoS One; 2015; 10(5):e0128321. PubMed ID: 26010138
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cervical spine ligamentum flavum gaps: MR characterisation and implications for interlaminar epidural injection therapy.
    Joshi J; Roytman M; Aiyer R; Mauer E; Chazen JL
    Reg Anesth Pain Med; 2022 Aug; 47(8):459-463. PubMed ID: 35580934
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Eyes in the needle: novel epidural needle with embedded high-frequency ultrasound transducer--epidural access in porcine model.
    Chiang HK; Zhou Q; Mandell MS; Tsou MY; Lin SP; Shung KK; Ting CK
    Anesthesiology; 2011 Jun; 114(6):1320-4. PubMed ID: 21519228
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Eyes to the needle: to assist identification of the epidural space.
    Pan PH; Sintay BJ
    Anesthesiology; 2010 May; 112(5):1073-5. PubMed ID: 20354437
    [No Abstract]   [Full Text] [Related]  

  • 18. Epidural block-induced ligamentum flavum hematoma mimicking epidural hematoma in the lumbar spine: a case report.
    Lee YS; Yi JS; Kim HJ; Kim JO; Choi ES
    Spine J; 2011 Feb; 11(2):e23-7. PubMed ID: 21296288
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lumbar ligamentum flavum: spatial relationships to surrounding anatomical structures and technical description of en bloc resection.
    Losiniecki AJ; Serrone JC; Keller JT; Bohinski RJ
    J Neurol Surg A Cent Eur Neurosurg; 2013 Nov; 74(6):388-92. PubMed ID: 23765919
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of the needle tip height on the puncture force in a simplified epidural anesthesia simulator.
    Naemura K; Uchino Y; Saito H
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3504-7. PubMed ID: 18002752
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.