These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 23369153)

  • 1. Dosimetry investigation of MOSFET for clinical IMRT dose verification.
    Deshpande S; Kumar R; Ghadi Y; Neharu RM; Kannan V
    Technol Cancer Res Treat; 2013 Jun; 12(3):193-8. PubMed ID: 23369153
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An in-house developed resettable MOSFET dosimeter for radiotherapy.
    Verellen D; Van Vaerenbergh S; Tournel K; Heuninckx K; Joris L; Duchateau M; Linthout N; Gevaert T; Reynders T; Van de Vondel I; Coppens L; Depuydt T; De Ridder M; Storme G
    Phys Med Biol; 2010 Feb; 55(4):N97-109. PubMed ID: 20090184
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of metal oxide field-effect transistors for first helical tomotherapy Hi-Art II unit in India.
    Kinhikar RA; Pai R; Master Z; Deshpande DD
    J Cancer Res Ther; 2009; 5(4):284-9. PubMed ID: 20160363
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of the use of MOSFET for clinical IMRT dosimetric verification.
    Chuang CF; Verhey LJ; Xia P
    Med Phys; 2002 Jun; 29(6):1109-15. PubMed ID: 12094980
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MOSFET detectors in quality assurance of tomotherapy treatments.
    Cherpak A; Studinski RC; Cygler JE
    Radiother Oncol; 2008 Feb; 86(2):242-50. PubMed ID: 18037519
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of a pulsed current annealing method in reusing MOSFET dosimeters for in vivo IMRT dosimetry.
    Luo GW; Qi ZY; Deng XW; Rosenfeld A
    Med Phys; 2014 May; 41(5):051710. PubMed ID: 24784376
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric evaluation of a MOSFET detector for clinical application in photon therapy.
    Kohno R; Hirano E; Nishio T; Miyagishi T; Goka T; Kawashima M; Ogino T
    Radiol Phys Technol; 2008 Jan; 1(1):55-61. PubMed ID: 20821164
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Commissioning and implementation of an implantable dosimeter for radiation therapy.
    Buzurovic I; Showalter TN; Studenski MT; Den RB; Dicker AP; Cao J; Xiao Y; Yu Y; Harrison A
    J Appl Clin Med Phys; 2013 Mar; 14(2):3989. PubMed ID: 23470929
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MOSFET dosimeter characterization in MR-guided radiation therapy (MRgRT) Linac.
    Yadav P; Hallil A; Tewatia D; Dunkerley DAP; Paliwal B
    J Appl Clin Med Phys; 2020 Jan; 21(1):127-135. PubMed ID: 31854078
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.
    Manigandan D; Bharanidharan G; Aruna P; Devan K; Elangovan D; Patil V; Tamilarasan R; Vasanthan S; Ganesan S
    Phys Med; 2009 Sep; 25(3):141-7. PubMed ID: 19128995
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental evaluation of a MOSFET dosimeter for proton dose measurements.
    Kohno R; Nishio T; Miyagishi T; Hirano E; Hotta K; Kawashima M; Ogino T
    Phys Med Biol; 2006 Dec; 51(23):6077-86. PubMed ID: 17110771
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry.
    Yoshizumi TT; Goodman PC; Frush DP; Nguyen G; Toncheva G; Sarder M; Barnes L
    AJR Am J Roentgenol; 2007 May; 188(5):1332-6. PubMed ID: 17449779
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Verification of the plan dosimetry for high dose rate brachytherapy using metal-oxide-semiconductor field effect transistor detectors.
    Qi ZY; Deng XW; Huang SM; Lu J; Lerch M; Cutajar D; Rosenfeld A
    Med Phys; 2007 Jun; 34(6):2007-13. PubMed ID: 17654904
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An optimized calibration method for surface measurements with MOSFETs in shaped-beam radiosurgery.
    Sors A; Cassol E; Latorzeff I; Duthil P; Sabatier J; Lotterie JA; Redon A; Berry I; Franceries X
    Phys Med; 2014 Feb; 30(1):10-7. PubMed ID: 23623590
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams.
    Jornet N; Carrasco P; Jurado D; Ruiz A; Eudaldo T; Ribas M
    Med Phys; 2004 Sep; 31(9):2534-42. PubMed ID: 15487735
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo real-time rectal wall dosimetry for prostate radiotherapy.
    Hardcastle N; Cutajar DL; Metcalfe PE; Lerch ML; Perevertaylo VL; Tomé WA; Rosenfeld AB
    Phys Med Biol; 2010 Jul; 55(13):3859-71. PubMed ID: 20571209
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of a new MOSFET detector configuration for in vivo skin dosimetry.
    Scalchi P; Francescon P; Rajaguru P
    Med Phys; 2005 Jun; 32(6):1571-8. PubMed ID: 16013716
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Establishing a standard calibration methodology for MOSFET detectors in computed tomography dosimetry.
    Brady SL; Kaufman RA
    Med Phys; 2012 Jun; 39(6):3031-40. PubMed ID: 22755688
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric validation of new semiconductor diode dosimetry system for intensity modulated radiotherapy.
    Kinhikar R; Chaudhari S; Kadam S; Dhote D; Deshpande D
    J Cancer Res Ther; 2012; 8(1):86-90. PubMed ID: 22531520
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of responses and comparison of calibration factor for commercial MOSFET detectors.
    Bharanidharan G; Manigandan D; Devan K; Subramani V; Gopishankar N; Ganesh T; Joshi R; Rath G; Velmurugan J; Aruna P; Ganesan S
    Med Dosim; 2005; 30(4):213-8. PubMed ID: 16275563
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.