21. Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography. Zou D; Grote L; Peker Y; Lindblad U; Hedner J Sleep; 2006 Mar; 29(3):367-74. PubMed ID: 16553023 [TBL] [Abstract][Full Text] [Related]
22. [Evaluation of a portable device based on peripheral arterial tone in the detection of obstructive sleep apnea]. Zhang J; Wang CY; Wang NY; Liu JQ; Du JY; Zhou GX; Yan ZF; Wen XH; Li L; Liu JF Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2012 Feb; 47(2):112-6. PubMed ID: 22455808 [TBL] [Abstract][Full Text] [Related]
23. Impact of Arterial Stiffness on WatchPAT Variables in Patients With Obstructive Sleep Apnea. Kinoshita T; Yahaba M; Terada J; Matsumura T; Sakurai Y; Nagashima K; Sakao S; Tatsumi K J Clin Sleep Med; 2018 Mar; 14(3):319-325. PubMed ID: 29458701 [TBL] [Abstract][Full Text] [Related]
24. Effectiveness of home single-channel nasal pressure for sleep apnea diagnosis. Masa JF; Duran-Cantolla J; Capote F; Cabello M; Abad J; Garcia-Rio F; Ferrer A; Mayos M; Gonzalez-Mangado N; de la Peña M; Aizpuru F; Barbe F; Montserrat JM; ; Larrateguy LD; de Castro JR; Garcia-Ledesma E; Utrabo I; Corral J; Martinez-Null C; Egea C; Cancelo L; García-Díaz E; Carmona-Bernal C; Sánchez-Armengol A; Fortuna AM; Miralda RM; Troncoso MF; Monica G; Martinez-Martinez M; Cantalejo O; Piérola J; Vigil L; Embid C; Del Mar Centelles M; Prieto TR; Rojo B; Vanesa L Sleep; 2014 Dec; 37(12):1953-61. PubMed ID: 25325484 [TBL] [Abstract][Full Text] [Related]
25. An investigation of the validity of the Lifeshirt in comparison to standard polysomnography in the detection of obstructive sleep apnea. Goodrich S; Orr WC Sleep Med; 2009 Jan; 10(1):118-22. PubMed ID: 18083629 [TBL] [Abstract][Full Text] [Related]
26. [Utility of the type 3 portable monitor for the diagnosis of patients with obstructive sleep apnea]. Wen YF; Chang Y; Xu LY; Dong XS; Zhao L; Zhang XL; Li J; Zuo YH; Zhang W; Gao YH; Han F Zhonghua Yi Xue Za Zhi; 2019 Oct; 99(38):2994-2999. PubMed ID: 31607031 [No Abstract] [Full Text] [Related]
27. Management of sleep apnea without high pretest probability or with comorbidities by three nights of portable sleep monitoring. Guerrero A; Embid C; Isetta V; Farre R; Duran-Cantolla J; Parra O; Barbé F; Montserrat JM; Masa JF Sleep; 2014 Aug; 37(8):1363-73. PubMed ID: 25083017 [TBL] [Abstract][Full Text] [Related]
28. The utility of a portable recording device for screening of obstructive sleep apnea in obese adolescents. Lesser DJ; Haddad GG; Bush RA; Pian MS J Clin Sleep Med; 2012 Jun; 8(3):271-7. PubMed ID: 22701384 [TBL] [Abstract][Full Text] [Related]
29. Comparing a combination of validated questionnaires and level III portable monitor with polysomnography to diagnose and exclude sleep apnea. Pereira EJ; Driver HS; Stewart SC; Fitzpatrick MF J Clin Sleep Med; 2013 Dec; 9(12):1259-66. PubMed ID: 24340287 [TBL] [Abstract][Full Text] [Related]
30. Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation. Pittman SD; Ayas NT; MacDonald MM; Malhotra A; Fogel RB; White DP Sleep; 2004 Aug; 27(5):923-33. PubMed ID: 15453551 [TBL] [Abstract][Full Text] [Related]
31. Comparison of home sleep apnea testing versus laboratory polysomnography for the diagnosis of obstructive sleep apnea in children. Scalzitti N; Hansen S; Maturo S; Lospinoso J; O'Connor P Int J Pediatr Otorhinolaryngol; 2017 Sep; 100():44-51. PubMed ID: 28802385 [TBL] [Abstract][Full Text] [Related]
32. Validation of a photoplethysmography device for detection of obstructive sleep apnea in the perioperative setting. Faßbender P; Haddad A; Bürgener S; Peters J J Clin Monit Comput; 2019 Apr; 33(2):341-345. PubMed ID: 29749570 [TBL] [Abstract][Full Text] [Related]
33. Detection of upper airway status and respiratory events by a current generation positive airway pressure device. Li QY; Berry RB; Goetting MG; Staley B; Soto-Calderon H; Tsai SC; Jasko JG; Pack AI; Kuna ST Sleep; 2015 Apr; 38(4):597-605. PubMed ID: 25409101 [TBL] [Abstract][Full Text] [Related]
34. Short-Term Variability in Apnea-Hypopnea Index during Extended Home Portable Monitoring. Prasad B; Usmani S; Steffen AD; Van Dongen HP; Pack FM; Strakovsky I; Staley B; Dinges D; Maislin G; Pack AI; Weaver TE J Clin Sleep Med; 2016 Jun; 12(6):855-63. PubMed ID: 26857059 [TBL] [Abstract][Full Text] [Related]
35. Comparison between the apnea-hypopnea indices determined by the REMstar Auto M series and those determined by standard in-laboratory polysomnography in patients with obstructive sleep apnea. Ikeda Y; Kasai T; Kawana F; Kasagi S; Takaya H; Ishiwata S; Narui K Intern Med; 2012; 51(20):2877-85. PubMed ID: 23064561 [TBL] [Abstract][Full Text] [Related]
36. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data. Huang HC; Hillman DR; McArdle N Sleep; 2012 Sep; 35(9):1277-83A. PubMed ID: 22942506 [TBL] [Abstract][Full Text] [Related]
37. Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Ayas NT; Pittman S; MacDonald M; White DP Sleep Med; 2003 Sep; 4(5):435-42. PubMed ID: 14592285 [TBL] [Abstract][Full Text] [Related]
38. Overnight polysomnography versus respiratory polygraphy in the diagnosis of pediatric obstructive sleep apnea. Tan HL; Gozal D; Ramirez HM; Bandla HP; Kheirandish-Gozal L Sleep; 2014 Feb; 37(2):255-60. PubMed ID: 24497654 [TBL] [Abstract][Full Text] [Related]
39. Obstructive sleep apnoea syndrome: comparison between polysomnography and portable sleep monitoring based on jaw recordings. Cheliout-Heraut F; Senny F; Djouadi F; Ouayoun M; Bour F Neurophysiol Clin; 2011 Oct; 41(4):191-8. PubMed ID: 22078731 [TBL] [Abstract][Full Text] [Related]