These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 2338000)

  • 1. Premature degradation of Abbott TDx reagents.
    Bacaj PJ; Boyd JC; Herold DA
    Clin Chem; 1990 May; 36(5):818. PubMed ID: 2338000
    [No Abstract]   [Full Text] [Related]  

  • 2. Positive interference of merthiolate in the TDx digoxin assay in control samples used in the Belgian External Quality Assessment (EQA) Scheme.
    Devleeschouwer N; Libeer JC; Schiettecatte J; Maes V; Demolder J; Debusschere PM; Gorus F
    Eur J Clin Chem Clin Biochem; 1994 Dec; 32(12):935-7. PubMed ID: 7696443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experience with cost-effective in-house reagents for the assay of carbamazepine in serum, using the Abbott TDx.
    Colbert DL; Turner GJ
    Ther Drug Monit; 1993 Jun; 15(3):209-12. PubMed ID: 8333000
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Digoxin-like immunoreactivity in the serum of neonates and uremic patients, as measured in the Abbott TDX.
    Yatscoff RW; Desjardins PR; Dalton JG
    Clin Chem; 1984 Apr; 30(4):588. PubMed ID: 6705215
    [No Abstract]   [Full Text] [Related]  

  • 5. Premature degradation of Abbott TDx reagents?
    Boeckx RL
    Clin Chem; 1990 Nov; 36(11):2010-1. PubMed ID: 2073280
    [No Abstract]   [Full Text] [Related]  

  • 6. Abbott TDx, Dade Stratus, and Du Pont aca automated digoxin immunoassays compared with a reference radioimmunoassay method.
    Clark DR; Inloes RL; Kalman SM; Sussman HH
    Clin Chem; 1986 Feb; 32(2):381-5. PubMed ID: 3943205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of digoxin-like immunoreactive factor on the TDx digoxin II assay.
    Frye R; Mathews SE
    Clin Chem; 1987 Apr; 33(4):629-30. PubMed ID: 3829416
    [No Abstract]   [Full Text] [Related]  

  • 8. Lack of interference by therapeutic concentrations of Inocor (amrinone lactate) in the TDx assay for digoxin.
    Coates JE; LeGatt DF
    Clin Chem; 1988 May; 34(5):1004-5. PubMed ID: 3370786
    [No Abstract]   [Full Text] [Related]  

  • 9. Evaluation of the Abbott ADx and TDx serum benzodiazepine immunoassays for analysis of alprazolam.
    Fraser AD; Bryan W
    J Anal Toxicol; 1991; 15(2):63-5. PubMed ID: 1675703
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is the TDx digoxin assay really overestimating?
    Grazioli V; Banfi G; Murone M; Bonini PA
    Clin Chem; 1988 May; 34(5):994-5. PubMed ID: 3370812
    [No Abstract]   [Full Text] [Related]  

  • 11. Mercurochrome interference with the Abbott TDx.
    Castellani WJ
    Clin Chem; 1992 Jun; 38(6):1190-1. PubMed ID: 1375874
    [No Abstract]   [Full Text] [Related]  

  • 12. An interlaboratory study of the determination of digoxin by immunoassay.
    Fast DM; Hannon WH; Burtis CA; Bayse DD
    Clin Chem; 1980 Mar; 26(3):480-6. PubMed ID: 6988112
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multicenter study of Abbott AxSYM Digoxin II assay and comparison with 6 methods for susceptibility to digoxin-like immunoreactive factors.
    Azzazy HM; Duh SH; Maturen A; Schaller E; Shaw L; Grimaldi R; Shock G; Christenson RH
    Clin Chem; 1997 Sep; 43(9):1635-40. PubMed ID: 9299945
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Laboratory intercomparison of commerical digoxin kits.
    Hansell JR
    Am J Clin Pathol; 1979 Aug; 72(2 Suppl):341-5. PubMed ID: 474512
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microgenics' Cedia assay for serum digoxin evaluated.
    Chan KM; Seifert EG; Endahl GL
    Clin Chem; 1988 Sep; 34(9):1932. PubMed ID: 3416472
    [No Abstract]   [Full Text] [Related]  

  • 16. Fluorescence polarization immunoassay of serum digoxin: comparison of the Abbott immunoassay with the Amerlex radioimmunoassay.
    Rawal N; Leung FY; Henderson AR
    Clin Chem; 1983 Mar; 29(3):586. PubMed ID: 6337747
    [No Abstract]   [Full Text] [Related]  

  • 17. Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.
    Porter WH; Haver VM; Bush BA
    Clin Chem; 1984 Nov; 30(11):1826-9. PubMed ID: 6207958
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative evaluation of the Abbott TDX, the Abbott ABA200, and the Syva LAB5000 for assay of serum gentamicin.
    Cheng AF; Lam AW; French GL
    J Antimicrob Chemother; 1987 Jan; 19(1):127-33. PubMed ID: 3549667
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An interlaboratory evaluation of the IFCC method for aspartate aminotransferase with use of purified enzyme materials.
    Sampson EJ; Whitner VS; Burtis CA; McKneally SS; Fast DM; Bayse DD
    Clin Chem; 1980 Jul; 26(8):1156-64. PubMed ID: 7389087
    [No Abstract]   [Full Text] [Related]  

  • 20. Syva Emit 2000 and Roche "on line" subject to less interference by digoxin-like factors than Abbott TDx FPIA in newborns and pregnant women.
    Sánchez BM; De Cos MA; Peralta FG; Arribas C; Armijo JA
    Clin Chem; 1996 Jun; 42(6 Pt 1):974-6. PubMed ID: 8665693
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.