386 related articles for article (PubMed ID: 23390037)
1. IS FlowMap, a novel tool to examine blood flow changes induced by flow diverter stent treatment: initial experiences with pipeline cases.
Chien A; Viñuela F
J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii43-7. PubMed ID: 23390037
[TBL] [Abstract][Full Text] [Related]
2. Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction.
Shobayashi Y; Tateshima S; Kakizaki R; Sudo R; Tanishita K; Viñuela F
J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii38-42. PubMed ID: 23048176
[TBL] [Abstract][Full Text] [Related]
3. Implantation of pipeline flow-diverting stents reduces aneurysm inflow without relevantly affecting static intra-aneurysmal pressure.
Kerl HU; Boll H; Fiebig T; Figueiredo G; Förster A; Nölte IS; Nonn A; Groden C; Brockmann MA
Neurosurgery; 2014 Mar; 74(3):321-34; discussion 334. PubMed ID: 24549048
[TBL] [Abstract][Full Text] [Related]
4. The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: computational fluid dynamics study.
Hassan T; Ahmed YM; Hassan AA
Acta Neurochir (Wien); 2011 Aug; 153(8):1633-40. PubMed ID: 21647821
[TBL] [Abstract][Full Text] [Related]
5. Neurovascular reconstruction with flow diverter stents for the treatment of 87 intracranial aneurysms: Clinical results.
Giacomini L; Piske RL; Baccin CE; Barroso M; Joaquim AF; Tedeschi H
Interv Neuroradiol; 2015 Jun; 21(3):292-9. PubMed ID: 25964435
[TBL] [Abstract][Full Text] [Related]
6. The Silk flow-diverter stent for endovascular treatment of intracranial aneurysms.
Alghamdi F; Morais R; Scillia P; Lubicz B
Expert Rev Med Devices; 2015; 12(6):753-62. PubMed ID: 26415045
[TBL] [Abstract][Full Text] [Related]
7. Aneurysm pressure measurement before and after placement of a Pipeline stent: feasibility study using a 0.014 inch pressure wire for coronary intervention.
Tateshima S; Jones JG; Mayor Basto F; Vinuela F; Duckwiler GR
J Neurointerv Surg; 2016 Jun; 8(6):603-7. PubMed ID: 24871764
[TBL] [Abstract][Full Text] [Related]
8. Hemodynamic Effect of Flow Diverter and Coils in Treatment of Large and Giant Intracranial Aneurysms.
Jing L; Zhong J; Liu J; Yang X; Paliwal N; Meng H; Wang S; Zhang Y
World Neurosurg; 2016 May; 89():199-207. PubMed ID: 26852712
[TBL] [Abstract][Full Text] [Related]
9. Using Leo Plus stent as flow diverter and endoluminal remodeling in endovascular treatment of intracranial fusiform aneurysms.
Pumar JM; Arias-Rivas S; Rodríguez-Yáñez M; Blanco M; Ageitos M; Vazquez-Herrero F; Castiñeira-Mourenza JA; Masso A
J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii22-7. PubMed ID: 23585639
[TBL] [Abstract][Full Text] [Related]
10. Treatment of two blood blister-like aneurysms with flow diverter stenting.
Consoli A; Nappini S; Renieri L; Limbucci N; Ricciardi F; Mangiafico S
J Neurointerv Surg; 2012 May; 4(3):e4. PubMed ID: 21990462
[TBL] [Abstract][Full Text] [Related]
11. [Application of Neuroform stent in the treatment of intracranial aneurysm].
Li YX; Li XF; Wu SC; Liu W
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2004 Dec; 26(6):647-50. PubMed ID: 15663225
[TBL] [Abstract][Full Text] [Related]
12. Utilization of the Navien distal intracranial catheter in 78 cases of anterior circulation aneurysm treatment with the Pipeline embolization device.
Colby GP; Lin LM; Huang J; Tamargo RJ; Coon AL
J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii16-21. PubMed ID: 23516269
[TBL] [Abstract][Full Text] [Related]
13. Visual outcomes with flow-diverter stents covering the ophthalmic artery for treatment of internal carotid artery aneurysms.
Rouchaud A; Leclerc O; Benayoun Y; Saleme S; Camilleri Y; D'Argento F; Boncoeur MP; Robert PY; Mounayer C
AJNR Am J Neuroradiol; 2015 Feb; 36(2):330-6. PubMed ID: 25339649
[TBL] [Abstract][Full Text] [Related]
14. SILK flow diverter for treatment of intracranial aneurysms: initial experience and cost analysis.
Shankar JJ; Vandorpe R; Pickett G; Maloney W
J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii11-5. PubMed ID: 23424227
[TBL] [Abstract][Full Text] [Related]
15. Endovascular treatment of very small intracranial aneurysms.
Chen Z; Feng H; Tang W; Liu Z; Miao H; Zhu G
Surg Neurol; 2008 Jul; 70(1):30-5; discussion 35. PubMed ID: 18262637
[TBL] [Abstract][Full Text] [Related]
16. Patency of the anterior choroidal artery covered with a flow-diverter stent.
Neki H; Caroff J; Jittapiromsak P; Benachour N; Mihalea C; Ikka L; Moret J; Spelle L
J Neurosurg; 2015 Dec; 123(6):1540-5. PubMed ID: 26047410
[TBL] [Abstract][Full Text] [Related]
17. Treatment of an internal carotid artery aneurysm with a flow diverter through a double lumen balloon catheter.
Amorim JM; Rosati S; Agid R; Pereira VM; Krings T
Interv Neuroradiol; 2017 Jun; 23(3):255-259. PubMed ID: 28604183
[TBL] [Abstract][Full Text] [Related]
18. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.
Cohen JE; Gomori JM; Moscovici S; Leker RR; Itshayek E
J Clin Neurosci; 2014 Jul; 21(7):1116-22. PubMed ID: 24524952
[TBL] [Abstract][Full Text] [Related]
19. Novel application of a balloon-anchoring technique for the realignment of a prolapsed pipeline embolization device: a technical report.
Crowley RW; Abla AA; Ducruet AF; McDougall CG; Albuquerque FC
J Neurointerv Surg; 2014 Jul; 6(6):439-44. PubMed ID: 23832416
[TBL] [Abstract][Full Text] [Related]
20. [Effects of flow diverter with low porosity on cerebral aneurysms: a numerical stimulative study].
Huang QH; Yang PF; Zhang X; Shi Y; Shao XM; Liu JM
Zhonghua Yi Xue Za Zhi; 2010 Apr; 90(15):1024-7. PubMed ID: 20646519
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]