199 related articles for article (PubMed ID: 23390086)
1. Cyclic sample pooling using two-dimensional liquid chromatography system enhances coverage in shotgun proteomics.
Kawashima Y; Satoh M; Saito T; Matsui T; Nomura F; Matsumoto H; Kodera Y
Biomed Chromatogr; 2013 Jun; 27(6):691-4. PubMed ID: 23390086
[TBL] [Abstract][Full Text] [Related]
2. Enhanced recovery of lyophilized peptides in shotgun proteomics by using an LC-ESI-MS compatible surfactant.
Kawashima Y; Takahashi N; Satoh M; Saito T; Kado S; Nomura F; Matsumoto H; Kodera Y
Proteomics; 2013 Mar; 13(5):751-5. PubMed ID: 23300112
[TBL] [Abstract][Full Text] [Related]
3. Shotgun proteome analysis utilising mixed mode (reversed phase-anion exchange chromatography) in conjunction with reversed phase liquid chromatography mass spectrometry analysis.
Phillips HL; Williamson JC; van Elburg KA; Snijders AP; Wright PC; Dickman MJ
Proteomics; 2010 Aug; 10(16):2950-60. PubMed ID: 20662100
[TBL] [Abstract][Full Text] [Related]
4. Analysis of peptides and protein digests by reversed phase high performance liquid chromatography-electrospray ionisation mass spectrometry using neutral pH elution conditions.
Yang Y; Boysen RI; Chowdhury J; Alam A; Hearn MT
Anal Chim Acta; 2015 May; 872():84-94. PubMed ID: 25892073
[TBL] [Abstract][Full Text] [Related]
5. Two-dimensional reversed-phase x ion-pair reversed-phase HPLC: an alternative approach to high-resolution peptide separation for shotgun proteome analysis.
Delmotte N; Lasaosa M; Tholey A; Heinzle E; Huber CG
J Proteome Res; 2007 Nov; 6(11):4363-73. PubMed ID: 17924683
[TBL] [Abstract][Full Text] [Related]
6. i-RUBY: a novel software for quantitative analysis of highly accurate shotgun-proteomics liquid chromatography/tandem mass spectrometry data obtained without stable-isotope labeling of proteins.
Wada K; Ogiwara A; Nagasaka K; Tanaka N; Komatsu Y
Rapid Commun Mass Spectrom; 2011 Apr; 25(7):960-8. PubMed ID: 21416533
[TBL] [Abstract][Full Text] [Related]
7. Microcapillary liquid chromatography/tandem mass spectrometry using alkaline pH mobile phases and positive ion detection.
Tomlinson AJ; Chicz RM
Rapid Commun Mass Spectrom; 2003; 17(9):909-16. PubMed ID: 12717763
[TBL] [Abstract][Full Text] [Related]
8. Fully automatable two-dimensional reversed-phase capillary liquid chromatography with online tandem mass spectrometry for shotgun proteomics.
Siu SO; Lam MP; Lau E; Kong RP; Lee SM; Chu IK
Proteomics; 2011 Jun; 11(11):2308-19. PubMed ID: 21548098
[TBL] [Abstract][Full Text] [Related]
9. Off-line two-dimensional liquid chromatography with maximized sample loading to reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry for shotgun proteome analysis.
Wang N; Xie C; Young JB; Li L
Anal Chem; 2009 Feb; 81(3):1049-60. PubMed ID: 19178338
[TBL] [Abstract][Full Text] [Related]
10. Multivariate comparison between peptide mass fingerprints obtained by liquid chromatography-electrospray ionization-mass spectrometry with different trypsin digestion procedures.
Bäckström D; Moberg M; Sjöberg PJ; Bergquist J; Danielsson R
J Chromatogr A; 2007 Nov; 1171(1-2):69-79. PubMed ID: 17927993
[TBL] [Abstract][Full Text] [Related]
11. Application of displacement chromatography for the proteome analysis of a human plasma protein fraction.
Ahrends R; Lichtner B; Bertsch A; Kohlbacher O; Hildebrand D; Trusch M; Schlüter H
J Chromatogr A; 2010 May; 1217(19):3321-9. PubMed ID: 19854443
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of enzymatic digestion and liquid chromatography-mass spectrometry peptide mapping of the integral membrane protein bacteriorhodopsin.
Hixson KK; Rodriguez N; Camp DG; Strittmatter EF; Lipton MS; Smith RD
Electrophoresis; 2002 Sep; 23(18):3224-32. PubMed ID: 12298094
[TBL] [Abstract][Full Text] [Related]
13. Protein identification assisted by the prediction of retention time in liquid chromatography/tandem mass spectrometry.
Wang Y; Zhang J; Gu X; Zhang XM
J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Nov; 826(1-2):122-8. PubMed ID: 16159714
[TBL] [Abstract][Full Text] [Related]
14. Integrated SDS removal and peptide separation by strong-cation exchange liquid chromatography for SDS-assisted shotgun proteome analysis.
Sun D; Wang N; Li L
J Proteome Res; 2012 Feb; 11(2):818-28. PubMed ID: 22214374
[TBL] [Abstract][Full Text] [Related]
15. Reversed-phase chromatography with multiple fraction concatenation strategy for proteome profiling of human MCF10A cells.
Wang Y; Yang F; Gritsenko MA; Wang Y; Clauss T; Liu T; Shen Y; Monroe ME; Lopez-Ferrer D; Reno T; Moore RJ; Klemke RL; Camp DG; Smith RD
Proteomics; 2011 May; 11(10):2019-26. PubMed ID: 21500348
[TBL] [Abstract][Full Text] [Related]
16. Shotgun analysis of membrane proteomes by an improved SDS-assisted sample preparation method coupled with liquid chromatography-tandem mass spectrometry.
Lin Y; Jiang H; Yan Y; Peng B; Chen J; Lin H; Liu Z
J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Dec; 911():6-14. PubMed ID: 23217299
[TBL] [Abstract][Full Text] [Related]
17. Development of online high-/low-pH reversed-phase-reversed-phase two-dimensional liquid chromatography for shotgun proteomics: a reversed-phase-strong cation exchange-reversed-phase approach.
Kong RP; Siu SO; Lee SS; Lo C; Chu IK
J Chromatogr A; 2011 Jun; 1218(23):3681-8. PubMed ID: 21531424
[TBL] [Abstract][Full Text] [Related]
18. Electrospray mass spectrometry for quantitative plasma proteome analysis.
Wang H; Hanash S
Methods Mol Biol; 2009; 564():227-42. PubMed ID: 19544026
[TBL] [Abstract][Full Text] [Related]
19. Peptide mapping with liquid chromatography using a basic mobile phase.
Liu H; Xu B; Ray MK; Shahrokh Z
J Chromatogr A; 2008 Nov; 1210(1):76-83. PubMed ID: 18838141
[TBL] [Abstract][Full Text] [Related]
20. Exploiting the complementary nature of LC/MALDI/MS/MS and LC/ESI/MS/MS for increased proteome coverage.
Bodnar WM; Blackburn RK; Krise JM; Moseley MA
J Am Soc Mass Spectrom; 2003 Sep; 14(9):971-9. PubMed ID: 12954165
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]