  • 1. Comparison between the Biflex III-Biotyper and the Axima-SARAMIS systems for yeast identification by matrix-assisted laser desorption ionization-time of flight mass spectrometry.
    Lohmann C; Sabou M; Moussaoui W; Prévost G; Delarbre JM; Candolfi E; Gravet A; Letscher-Bru V
    J Clin Microbiol; 2013 Apr; 51(4):1231-6. PubMed ID: 23390281
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Molecular and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based Characterization of Clinically Significant Melanized Fungi in India.
    Singh A; Singh PK; Kumar A; Chander J; Khanna G; Roy P; Meis JF; Chowdhary A
    J Clin Microbiol; 2017 Apr; 55(4):1090-1103. PubMed ID: 28100598
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of matrix-assisted laser desorption-time of flight mass spectrometry for identification of clinical yeast isolates.
    Rosenvinge FS; Dzajic E; Knudsen E; Malig S; Andersen LB; Løvig A; Arendrup MC; Jensen TG; Gahrn-Hansen B; Kemp M
    Mycoses; 2013 May; 56(3):229-35. PubMed ID: 22924975
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative evaluation of the Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry systems for identification of yeasts of medical importance.
    Mancini N; De Carolis E; Infurnari L; Vella A; Clementi N; Vaccaro L; Ruggeri A; Posteraro B; Burioni R; Clementi M; Sanguinetti M
    J Clin Microbiol; 2013 Jul; 51(7):2453-7. PubMed ID: 23678071
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative evaluation of the Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems for non-albicans Candida and uncommon yeast isolates.
    Teke L; Barış A; Bayraktar B
    J Microbiol Methods; 2021 Jun; 185():106232. PubMed ID: 33961963
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of clinically important yeast species.
    Stevenson LG; Drake SK; Shea YR; Zelazny AM; Murray PR
    J Clin Microbiol; 2010 Oct; 48(10):3482-6. PubMed ID: 20668126
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Misidentification of a Rare Species, Cryptococcus laurentii, by Commonly Used Commercial Biochemical Methods and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Systems: Challenges for Clinical Mycology Laboratories.
    Xiao M; Fan X; Chen XX; Wang H; Zhang L; Xu ZP; Kudinha T; Kong F; Xu YC
    J Clin Microbiol; 2016 Jan; 54(1):226-9. PubMed ID: 26560541
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a clinically comprehensive database and a simple procedure for identification of molds from solid media by matrix-assisted laser desorption ionization-time of flight mass spectrometry.
    Lau AF; Drake SK; Calhoun LB; Henderson CM; Zelazny AM
    J Clin Microbiol; 2013 Mar; 51(3):828-34. PubMed ID: 23269728
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison and optimization of two MALDI-TOF MS platforms for the identification of medically relevant yeast species.
    Pence MA; McElvania TeKippe E; Wallace MA; Burnham CA
    Eur J Clin Microbiol Infect Dis; 2014 Oct; 33(10):1703-12. PubMed ID: 24800928
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Advantages of using matrix-assisted laser desorption ionization-time of flight mass spectrometry as a rapid diagnostic tool for identification of yeasts and mycobacteria in the clinical microbiological laboratory.
    Chen JH; Yam WC; Ngan AH; Fung AM; Woo WL; Yan MK; Choi GK; Ho PL; Cheng VC; Yuen KY
    J Clin Microbiol; 2013 Dec; 51(12):3981-7. PubMed ID: 24048537
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of the Bruker MALDI Biotyper for identification of molds in the clinical mycology laboratory.
    Schulthess B; Ledermann R; Mouttet F; Zbinden A; Bloemberg GV; Böttger EC; Hombach M
    J Clin Microbiol; 2014 Aug; 52(8):2797-803. PubMed ID: 24850347
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of an expanded, in-house library and an optimized preparation method for the identification of fungal isolates using MALDI-TOF mass spectrometry.
    Zvezdanova ME; de Aledo MG; López-Mirones JI; Ortega J; Canut A; Castro C; Gomez C; Hernáez S; Oviaño M; Ercibengoa M; Alkorta M; Muñoz P; Rodriguez-Temporal D; Rodríguez-Sánchez B
    Med Mycol; 2023 Apr; 61(4):. PubMed ID: 37102224
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Candida guilliermondii and other species of candida misidentified as Candida famata: assessment by vitek 2, DNA sequencing analysis, and matrix-assisted laser desorption ionization-time of flight mass spectrometry in two global antifungal surveillance programs.
    Castanheira M; Woosley LN; Diekema DJ; Jones RN; Pfaller MA
    J Clin Microbiol; 2013 Jan; 51(1):117-24. PubMed ID: 23100350
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi.
    McMullen AR; Wallace MA; Pincus DH; Wilkey K; Burnham CA
    J Clin Microbiol; 2016 Aug; 54(8):2068-73. PubMed ID: 27225405
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of two matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems for the identification of Candida species.
    Lacroix C; Gicquel A; Sendid B; Meyer J; Accoceberry I; François N; Morio F; Desoubeaux G; Chandenier J; Kauffmann-Lacroix C; Hennequin C; Guitard J; Nassif X; Bougnoux ME
    Clin Microbiol Infect; 2014 Feb; 20(2):153-8. PubMed ID: 23594150
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved identification of yeast species directly from positive blood culture media by combining Sepsityper specimen processing and Microflex analysis with the matrix-assisted laser desorption ionization Biotyper system.
    Yan Y; He Y; Maier T; Quinn C; Shi G; Li H; Stratton CW; Kostrzewa M; Tang YW
    J Clin Microbiol; 2011 Jul; 49(7):2528-32. PubMed ID: 21543564
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) for rapid identification of micro-organisms in the routine clinical microbiology laboratory.
    Wattal C; Oberoi JK; Goel N; Raveendran R; Khanna S
    Eur J Clin Microbiol Infect Dis; 2017 May; 36(5):807-812. PubMed ID: 27987046
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of a New Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Platform, ASTA MicroIDSys, With Bruker Biotyper for Species Identification.
    Lee Y; Sung JY; Kim H; Yong D; Lee K
    Ann Lab Med; 2017 Nov; 37(6):531-535. PubMed ID: 28840993
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Matrix-assisted laser desorption/ionization-time of flight mass spectrometry: protocol standardization and database expansion for rapid identification of clinically important molds.
    Paul S; Singh P; Rudramurthy SM; Chakrabarti A; Ghosh AK
    Future Microbiol; 2017 Dec; 12():1457-1466. PubMed ID: 29073795
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry systems for the identification of clinical filamentous fungi.
    Huang Y; Zhang M; Zhu M; Wang M; Sun Y; Gu H; Cao J; Li X; Zhang S; Wang J; Lu X
    World J Microbiol Biotechnol; 2017 Jul; 33(7):142. PubMed ID: 28608323
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]