443 related articles for article (PubMed ID: 23395242)
1. Evaluation of an electromagnetic image-fusion navigation system for biopsy of small lesions: assessment of accuracy in an in vivo swine model.
Appelbaum L; Solbiati L; Sosna J; Nissenbaum Y; Greenbaum N; Goldberg SN
Acad Radiol; 2013 Feb; 20(2):209-17. PubMed ID: 23395242
[TBL] [Abstract][Full Text] [Related]
2. Targeting liver lesions for radiofrequency ablation: an experimental feasibility study using a CT-US fusion imaging system.
Crocetti L; Lencioni R; Debeni S; See TC; Pina CD; Bartolozzi C
Invest Radiol; 2008 Jan; 43(1):33-9. PubMed ID: 18097275
[TBL] [Abstract][Full Text] [Related]
3. Electromagnetic navigation system for CT-guided biopsy of small lesions.
Appelbaum L; Sosna J; Nissenbaum Y; Benshtein A; Goldberg SN
AJR Am J Roentgenol; 2011 May; 196(5):1194-200. PubMed ID: 21512092
[TBL] [Abstract][Full Text] [Related]
4. Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy.
Krücker J; Xu S; Glossop N; Viswanathan A; Borgert J; Schulz H; Wood BJ
J Vasc Interv Radiol; 2007 Sep; 18(9):1141-50. PubMed ID: 17804777
[TBL] [Abstract][Full Text] [Related]
5. Freehand versus guided breast biopsy: comparison of accuracy, needle motion, and biopsy time in a tissue model.
Bluvol N; Kornecki A; Shaikh A; Del Rey Fernandez D; Taves DH; Fenster A
AJR Am J Roentgenol; 2009 Jun; 192(6):1720-5. PubMed ID: 19457840
[TBL] [Abstract][Full Text] [Related]
6. C-Arm Cone-Beam CT Combined with a New Electromagnetic Navigation System for Guidance of Percutaneous Needle Biopsies: Initial Clinical Experience.
Kickuth R; Reichling C; Bley T; Hahn D; Ritter C
Rofo; 2015 Jul; 187(7):569-76. PubMed ID: 26090650
[TBL] [Abstract][Full Text] [Related]
7. Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine.
Banovac F; Tang J; Xu S; Lindisch D; Chung HY; Levy EB; Chang T; McCullough MF; Yaniv Z; Wood BJ; Cleary K
Med Phys; 2005 Aug; 32(8):2698-705. PubMed ID: 16193801
[TBL] [Abstract][Full Text] [Related]
8. Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.
Shahriari N; Heerink W; van Katwijk T; Hekman E; Oudkerk M; Misra S
Med Eng Phys; 2017 Jul; 45():71-77. PubMed ID: 28512000
[TBL] [Abstract][Full Text] [Related]
9. Rapid freehand MR-guided percutaneous needle interventions: an image-based approach to improve workflow and feasibility.
Rothgang E; Gilson WD; Wacker F; Hornegger J; Lorenz CH; Weiss CR
J Magn Reson Imaging; 2013 May; 37(5):1202-12. PubMed ID: 23334924
[TBL] [Abstract][Full Text] [Related]
10. Comparison of Two Electromagnetic Navigation Systems For CT-Guided Punctures: A Phantom Study.
Putzer D; Arco D; Schamberger B; Schanda F; Mahlknecht J; Widmann G; Schullian P; Jaschke W; Bale R
Rofo; 2016 May; 188(5):470-8. PubMed ID: 27074422
[TBL] [Abstract][Full Text] [Related]
11. Improved targeting accuracy of lung tumor biopsies with scanning-beam digital x-ray tomosynthesis image guidance.
Nelson G; Wu M; Hinkel C; Krishna G; Funk T; Rosenberg J; Fahrig R
Med Phys; 2016 Dec; 43(12):6282. PubMed ID: 27908166
[TBL] [Abstract][Full Text] [Related]
12. CT-guided interventions using a free-hand, optical tracking system: initial clinical experience.
Schubert T; Jacob AL; Pansini M; Liu D; Gutzeit A; Kos S
Cardiovasc Intervent Radiol; 2013 Aug; 36(4):1055-62. PubMed ID: 23232857
[TBL] [Abstract][Full Text] [Related]
13. An electromagnetic navigation system for transbronchial interventions with a novel approach to respiratory motion compensation.
Gergel I; Hering J; Tetzlaff R; Meinzer HP; Wegner I
Med Phys; 2011 Dec; 38(12):6742-53. PubMed ID: 22149856
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of a CT-Guided Robotic System for Precise Percutaneous Needle Insertion.
Ben-David E; Shochat M; Roth I; Nissenbaum I; Sosna J; Goldberg SN
J Vasc Interv Radiol; 2018 Oct; 29(10):1440-1446. PubMed ID: 29628297
[TBL] [Abstract][Full Text] [Related]
15. Percutaneous punctures with MR imaging guidance: comparison between MR imaging-enhanced fluoroscopic guidance and real-time MR Imaging guidance.
Meyer BC; Brost A; Kraitchman DL; Gilson WD; Strobel N; Hornegger J; Lewin JS; Wacker FK
Radiology; 2013 Mar; 266(3):912-9. PubMed ID: 23297324
[TBL] [Abstract][Full Text] [Related]
16. Percutaneous radiofrequency ablation of virtual tumours in canine kidney using Global Positioning System-like technology.
Hung AJ; Ma Y; Zehnder P; Nakamoto M; Gill IS; Ukimura O
BJU Int; 2012 May; 109(9):1398-403. PubMed ID: 21992738
[TBL] [Abstract][Full Text] [Related]
17. A needle guidance system for biopsy and therapy using two-dimensional ultrasound.
Bluvol N; Sheikh A; Kornecki A; Fernandez Ddel R; Downey D; Fenster A
Med Phys; 2008 Feb; 35(2):617-28. PubMed ID: 18383683
[TBL] [Abstract][Full Text] [Related]
18. A novel accurate minioptical tracking system for percutaneous needle placement.
von Jako CR; Zuk Y; Zur O; Gilboa P
IEEE Trans Biomed Eng; 2013 Aug; 60(8):2222-5. PubMed ID: 23481683
[TBL] [Abstract][Full Text] [Related]
19. Navigation-based needle puncture of a cadaver using a hybrid tracking navigational system.
Khan MF; Dogan S; Maataoui A; Wesarg S; Gurung J; Ackermann H; Schiemann M; Wimmer-Greinecker G; Vogl TJ
Invest Radiol; 2006 Oct; 41(10):713-20. PubMed ID: 16971794
[TBL] [Abstract][Full Text] [Related]
20. Implementation of an electromagnetic tracking system for accurate intrahepatic puncture needle guidance: accuracy results in an in vitro model.
Levy EB; Tang J; Lindisch D; Glossop N; Banovac F; Cleary K
Acad Radiol; 2007 Mar; 14(3):344-54. PubMed ID: 17307668
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]