These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 2339817)

  • 1. Complications related to the use of a heat and moisture exchanger.
    Prasad KK; Chen L
    Anesthesiology; 1990 May; 72(5):958. PubMed ID: 2339817
    [No Abstract]   [Full Text] [Related]  

  • 2. A dangerous defect in a heat and moisture exchanger.
    Prados W
    Anesthesiology; 1989 Nov; 71(5):804. PubMed ID: 2817482
    [No Abstract]   [Full Text] [Related]  

  • 3. Critical incident involving a heat and moisture exchanger with attached flexible connector.
    Mansor M; Chan L
    Anaesth Intensive Care; 1999 Feb; 27(1):114-5. PubMed ID: 10050234
    [No Abstract]   [Full Text] [Related]  

  • 4. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.
    Parmar V
    J Indian Med Assoc; 2008 Aug; 106(8):533-5, 537. PubMed ID: 18975515
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of a hygroscopic heat and moisture exchanger for paediatric use.
    Wilkinson KA; Cranston A; Hatch DJ; Fletcher ME
    Anaesthesia; 1991 Apr; 46(4):296-9. PubMed ID: 2024750
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Changes in ventilation during use of heat and humidity exchangers].
    Croci M; Corrado F; Sibilla E; Tiby A; Vercesi G; Proietti D; Vannucci A
    Minerva Anestesiol; 1991; 57(1-2):13-6. PubMed ID: 2057084
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resistance to gas flow in heat and moisture exchangers.
    Wilkes AR
    Anaesthesia; 1992 Dec; 47(12):1095-6. PubMed ID: 1489046
    [No Abstract]   [Full Text] [Related]  

  • 8. [Comparison of 2 exchangers of heat and humidity in anesthesia (Hygrobac vs Ultipor BB50)].
    Zamaro G; Romano E; Molassi M
    Minerva Anestesiol; 1989 Sep; 55(9):363-5. PubMed ID: 2633085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative ex vivo study on humidifying function of three speaking valves with integrated heat and moisture exchanger for tracheotomised patients.
    van den Boer C; Lansaat L; Muller SH; van den Brekel MW; Hilgers FJ
    Clin Otolaryngol; 2015 Dec; 40(6):616-21. PubMed ID: 25823941
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Humidity in a Low-Flow Dräger Fabius Anesthesia Workstation with or without Thermal Insulation or a Heat and Moisture Exchanger: A Prospective Randomized Clinical Trial.
    de Oliveira SA; Lucio LM; Modolo NS; Hayashi Y; Braz MG; de Carvalho LR; Braz LG; Braz JR
    PLoS One; 2017; 12(1):e0170723. PubMed ID: 28129353
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of humidifying devices on the measurement of tidal volume by mechanical ventilators.
    Fujita Y; Imanaka H; Fujino Y; Takeuchi M; Tomita T; Mashimo T; Nishimura M
    J Anesth; 2006; 20(3):166-72. PubMed ID: 16897234
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Heat and moisture exchangers and breathing filters.
    Hedley RM; Allt-Graham J
    Br J Anaesth; 1994 Aug; 73(2):227-36. PubMed ID: 7917741
    [No Abstract]   [Full Text] [Related]  

  • 13. [Prevention of contamination with a heat-and-moisture-exchanger (HME) and bacterial filter during clinical anesthesia].
    Shibata M; Asano M
    Masui; 1998 Dec; 47(12):1464-70. PubMed ID: 9990215
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficiency of airway heat and moisture exchangers in anesthetized humans.
    Bickler PE; Sessler DI
    Anesth Analg; 1990 Oct; 71(4):415-8. PubMed ID: 2400121
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of heat and moisture exchanger efficiency.
    Chandler M
    Anaesthesia; 2013 Sep; 68(9):953-60. PubMed ID: 24047355
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sterilization by heat.
    Schneierson SS
    Int Anesthesiol Clin; 1972; 10(2):67-83. PubMed ID: 4662524
    [No Abstract]   [Full Text] [Related]  

  • 17. An unusual cause of gas pipeline failure.
    Ewart IA
    Anaesthesia; 1990 Jun; 45(6):498. PubMed ID: 2382816
    [No Abstract]   [Full Text] [Related]  

  • 18. Do passive heat and moisture exchangers keep the patient warm?
    Haslam KR; Nielsen CH
    Anesthesiology; 1986 Mar; 64(3):379-81. PubMed ID: 3456733
    [No Abstract]   [Full Text] [Related]  

  • 19. Sudden complete obstruction of breathing circuit during postural change upon completion of thoracic spinal surgery in a pediatric patient.
    Wang YM; Chen CS; Chung NC; Ye XD; Liu K
    Acta Anaesthesiol Sin; 2003 Sep; 41(3):145-8. PubMed ID: 14601201
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical effects of airway humidification devices in difficult to wean patients.
    Girault C; Breton L; Richard JC; Tamion F; Vandelet P; Aboab J; Leroy J; Bonmarchand G
    Crit Care Med; 2003 May; 31(5):1306-11. PubMed ID: 12771595
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.