These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 23400172)

  • 1. Simulation of the aortic valve deformation by considering blood flow reflection.
    Mukai N; Nakagawa M; Abe Y; Chang Y; Niki K; Takanashi S
    Stud Health Technol Inform; 2013; 184():286-92. PubMed ID: 23400172
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Particle Based Simulation of the Aortic Valve by Considering Heart's Pulsation.
    Mukai N; Abe Y; Chang Y; Niki K; Takanashi S
    Stud Health Technol Inform; 2014; 196():285-9. PubMed ID: 24732523
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Numerical validation of a new method to assess aortic pulse wave velocity from a single recording of a brachial artery waveform with an occluding cuff.
    Trachet B; Reymond P; Kips J; Swillens A; De Buyzere M; Suys B; Stergiopulos N; Segers P
    Ann Biomed Eng; 2010 Mar; 38(3):876-88. PubMed ID: 20127171
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A coupled fluid-structure finite element model of the aortic valve and root.
    Nicosia MA; Cochran RP; Einstein DR; Rutland CJ; Kunzelman KS
    J Heart Valve Dis; 2003 Nov; 12(6):781-9. PubMed ID: 14658821
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wall stress and deformation analysis in a numerical model of pulse wave propagation.
    He F; Hua L; Gao L
    Biomed Mater Eng; 2015; 26 Suppl 1():S527-32. PubMed ID: 26406044
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and validation of a computational fluid dynamics methodology for simulation of pulsatile left ventricular assist devices.
    Medvitz RB; Kreider JW; Manning KB; Fontaine AA; Deutsch S; Paterson EG
    ASAIO J; 2007; 53(2):122-31. PubMed ID: 17413548
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel wave reflection model of the human arterial system.
    Zhang H; Li JK
    Cardiovasc Eng; 2009 Jun; 9(2):39-48. PubMed ID: 19495973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The sinus of Valsalva relieves abnormal stress on aortic valve leaflets by facilitating smooth closure.
    Katayama S; Umetani N; Sugiura S; Hisada T
    J Thorac Cardiovasc Surg; 2008 Dec; 136(6):1528-35, 1535.e1. PubMed ID: 19114202
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analytical modeling of the instantaneous pressure gradient across the aortic valve.
    Garcia D; Pibarot P; Durand LG
    J Biomech; 2005 Jun; 38(6):1303-11. PubMed ID: 15863115
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional coupled fluid-structure simulation of pericardial bioprosthetic aortic valve function.
    Makhijani VB; Yang HQ; Dionne PJ; Thubrikar MJ
    ASAIO J; 1997; 43(5):M387-92. PubMed ID: 9360067
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Investigation of pulsatile flowfield in healthy thoracic aorta models.
    Wen CY; Yang AS; Tseng LY; Chai JW
    Ann Biomed Eng; 2010 Feb; 38(2):391-402. PubMed ID: 19890715
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On the opening mechanism of the aortic valve: some observations from simulations.
    Howard IC; Patterson EA; Yoxall A
    J Med Eng Technol; 2003; 27(6):259-66. PubMed ID: 14602517
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Neonatal aortic arch hemodynamics and perfusion during cardiopulmonary bypass.
    Pekkan K; Dur O; Sundareswaran K; Kanter K; Fogel M; Yoganathan A; Undar A
    J Biomech Eng; 2008 Dec; 130(6):061012. PubMed ID: 19045541
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro evaluation of the long-body On-X bileaflet heart valve.
    Hwang NH; Reul H; Reinhard P
    J Heart Valve Dis; 1998 Sep; 7(5):561-8. PubMed ID: 9793857
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimation of viscous dissipative stresses induced by a mechanical heart valve using PIV data.
    Li CP; Lo CW; Lu PC
    Ann Biomed Eng; 2010 Mar; 38(3):903-16. PubMed ID: 20020213
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fluid-structure interaction of a pulsatile flow with an aortic valve model: A combined experimental and numerical study.
    Sigüenza J; Pott D; Mendez S; Sonntag SJ; Kaufmann TAS; Steinseifer U; Nicoud F
    Int J Numer Method Biomed Eng; 2018 Apr; 34(4):e2945. PubMed ID: 29181891
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electric analog model of the aortic valve for calculation of continuous beat-to-beat aortic flow using a pressure gradient.
    Graen MD; Ewert DL; Glower JS; Gray LA; Koenig SC
    ASAIO J; 1999; 45(3):204-10. PubMed ID: 10360724
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Direct numerical simulation of a 2D-stented aortic heart valve at physiological flow rates.
    Dimakopoulos Y; Bogaerds AC; Anderson PD; Hulsen MA; Baaijens FP
    Comput Methods Biomech Biomed Engin; 2012; 15(11):1157-79. PubMed ID: 22185614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An approach to the simulation of fluid-structure interaction in the aortic valve.
    Carmody CJ; Burriesci G; Howard IC; Patterson EA
    J Biomech; 2006; 39(1):158-69. PubMed ID: 16271600
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of the aortic valve leaflets on the fluid-dynamics in aorta in presence of a normally functioning bicuspid valve.
    Bonomi D; Vergara C; Faggiano E; Stevanella M; Conti C; Redaelli A; Puppini G; Faggian G; Formaggia L; Luciani GB
    Biomech Model Mechanobiol; 2015 Nov; 14(6):1349-61. PubMed ID: 25943772
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.