170 related articles for article (PubMed ID: 2340214)
1. Computerized tomography with and without intraperitoneal contrast for determination of intraabdominal fluid distribution and diagnosis of complications in peritoneal dialysis patients.
Twardowski ZJ; Tully RJ; Ersoy FF; Dedhia NM
ASAIO Trans; 1990; 36(2):95-103. PubMed ID: 2340214
[TBL] [Abstract][Full Text] [Related]
2. Complications of continuous ambulatory peritoneal dialysis: evaluation with CT peritoneography.
Hollett MD; Marn CS; Ellis JH; Francis IR; Swartz RD
AJR Am J Roentgenol; 1992 Nov; 159(5):983-9. PubMed ID: 1344976
[TBL] [Abstract][Full Text] [Related]
3. Modified computed tomography peritoneography: clinical utility in continuous ambulatory peritoneal dialysis patients.
Hawkins SP; Homer JA; Murray BB; Voss DM; van der Merwe WM
Australas Radiol; 2000 Nov; 44(4):398-403. PubMed ID: 11103537
[TBL] [Abstract][Full Text] [Related]
4. Complications of peritoneal dialysis: evaluation with CT peritoneography.
Cochran ST; Do HM; Ronaghi A; Nissenson AR; Kadell BM
Radiographics; 1997; 17(4):869-78. PubMed ID: 9225388
[TBL] [Abstract][Full Text] [Related]
5. Transvaginal leak of peritoneal dialysate demonstrated by CT peritoneography.
Bradley AJ; Mamtora H; Pritchard N
Br J Radiol; 1997 Jun; 70(834):652-3. PubMed ID: 9227262
[TBL] [Abstract][Full Text] [Related]
6. Complications of continuous ambulatory peritoneal dialysis: evaluation with CT.
Cakir B; Kirbaş I; Cevik B; Ulu EM; Bayrak A; Coşkun M
Diagn Interv Radiol; 2008 Dec; 14(4):212-20. PubMed ID: 19061167
[TBL] [Abstract][Full Text] [Related]
7. CT peritoneography in evaluation of pediatric dialysis complications.
Magill HL; Roy S; Stapleton FB
AJR Am J Roentgenol; 1986 Aug; 147(2):325-8. PubMed ID: 3487950
[TBL] [Abstract][Full Text] [Related]
8. Computed tomographic peritoneography: CT manifestations in the investigation of leaks and abnormal collections in patients on CAPD.
Litherland J; Lupton EW; Ackrill PA; Venning M; Sambrook P
Nephrol Dial Transplant; 1994; 9(10):1449-52. PubMed ID: 7816259
[TBL] [Abstract][Full Text] [Related]
9. MR peritoneography in complications of continuous ambulatory peritoneal dialysis.
Yavuz K; Erden A; Ateş K; Erden I
Abdom Imaging; 2005; 30(3):361-8. PubMed ID: 15688110
[TBL] [Abstract][Full Text] [Related]
10. A CT evaluation of the intraperitoneal fluid distribution.
Wójtowicz J; Rzymski K; Czarnecki R
Rofo; 1982 Jul; 137(1):95-9. PubMed ID: 6213537
[TBL] [Abstract][Full Text] [Related]
11. Complications of continuous ambulatory peritoneal dialysis: findings on MR peritoneography.
Prokesch RW; Schima W; Schober E; Vychytil A; Fabrizii V; Bader TR
AJR Am J Roentgenol; 2000 Apr; 174(4):987-91. PubMed ID: 10749235
[TBL] [Abstract][Full Text] [Related]
12. CT in patients with blunt abdominal trauma: clinical significance of intraperitoneal fluid detected on a scan with otherwise normal findings.
Levine CD; Patel UJ; Wachsberg RH; Simmons MZ; Baker SR; Cho KC
AJR Am J Roentgenol; 1995 Jun; 164(6):1381-5. PubMed ID: 7754877
[TBL] [Abstract][Full Text] [Related]
13. Compatibility and stability of non-ionic iodinated contrast media in peritoneal dialysis solution and safe practice considerations for CT peritoneography.
Rappai J; Crabtree JH; Mancini A; Badugu SK; Kaushal A; Gellens ME
Perit Dial Int; 2023 Mar; 43(2):151-158. PubMed ID: 35505602
[TBL] [Abstract][Full Text] [Related]
14. [Diagnostic value of CT peritoneography for non-infectious complications of peritoneal dialysis].
Wang Q; Ni ZH; Zhu ML; Mou S; Cao LO; Fang W
Zhong Xi Yi Jie He Xue Bao; 2008 May; 6(5):478-81. PubMed ID: 18471411
[TBL] [Abstract][Full Text] [Related]
15. [The role of CT peritoneography as diagnostic tool in patient on peritoneal dialysis with dialysate leakage].
Markić D; Zivcić-Cosić S; Valencić M; Miletić D; Rahelić D; Krpina K; Maricić A; Pavlović I; Racki S; Fuckar Z
Acta Med Croatica; 2011 Oct; 65 Suppl 3():95-8. PubMed ID: 23120824
[TBL] [Abstract][Full Text] [Related]
16. [99mTc-MAA peritoneal scintigraphy in pleuroperitoneal comunication in peritoneal dialysis patients].
Hernández Martínez AC; Marín Ferrer MD; Coronado Poggio M; Escabias Del Pozo C; Coya Viña J; Martín Curto L
Rev Esp Med Nucl; 2010; 29(2):84-6. PubMed ID: 20117860
[TBL] [Abstract][Full Text] [Related]
17. Imaging work-up for peritoneal access care and peritoneal dialysis complications.
Scanziani R; Pozzi M; Pisano L; Santagostino Barbone G; Dozio B; Rovere G; Gabella P; Magrì F
Int J Artif Organs; 2006 Jan; 29(1):142-52. PubMed ID: 16485250
[TBL] [Abstract][Full Text] [Related]
18. Low attenuation of acute traumatic hemoperitoneum on CT scans.
Levine CD; Patel UJ; Silverman PM; Wachsberg RH
AJR Am J Roentgenol; 1996 May; 166(5):1089-93. PubMed ID: 8615249
[TBL] [Abstract][Full Text] [Related]
19. [Contribution of peritoneography combined with computerized tomography, in the assessment of abdominal complications in patients undergoing continuous peritoneal dialysis].
Caimi F; Rovere G; Philippson M; Battaglia E
Radiol Med; 1991 May; 81(5):656-9. PubMed ID: 2057592
[TBL] [Abstract][Full Text] [Related]
20. Value of magnetic resonance/computed tomography peritoneography technique in the evaluation of dialysate leakage and hernia following peritoneal dialysis.
Theodorou DJ; Theodorou SJ; Mantzoukis F; Androulaki M; Kokkolou E; Andrikos E; Sferopoulos G
Int J Artif Organs; 2020 Feb; 43(2):94-98. PubMed ID: 31544578
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]