BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 23404014)

  • 1. A comparative evaluation of the dimensional accuracy of heat polymerized acrylic resin denture base clamped by the conventional method and by new-press technique and cured by long curing cycle: an in vitro study.
    Shankar T; Gowd S; Ahmed ST; Vinod V; Goud MV; Rao NV
    J Contemp Dent Pract; 2012 Nov; 13(6):842-9. PubMed ID: 23404014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparative evaluation of the dimensional accuracy of heat polymerised PMMA denture base cured by different curing cycles and clamped by R S technique and conventional method - An In-vitro study.
    Babu MR; Rao CS; Ahmed ST; Bharat JS; Rao NV; Vinod V
    J Int Oral Health; 2014 Apr; 6(2):68-75. PubMed ID: 24876705
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of the linear dimensional accuracy of denture bases cured the by conventional method and by the new press technique.
    Abby A; Kumar R; Shibu J; Chakravarthy R
    Indian J Dent Res; 2011; 22(2):200-4. PubMed ID: 21891885
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dimensional stability of record bases fabricated from light-polymerized composite using two methods.
    Boberick KG; McCool J
    J Prosthet Dent; 1998 Apr; 79(4):399-403. PubMed ID: 9576313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of Adaptability and Linear Dimensional Changes of Two Heat Cure Denture Base Resin with Different Cooling Techniques: An
    Kannaiyan K; Rathod A; Bhushan P; Mailankote S; Almuraikhi T; Daghriri A
    J Contemp Dent Pract; 2024 Mar; 25(3):241-244. PubMed ID: 38690697
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases.
    Consani RL; Domitti SS; Consani S
    J Prosthet Dent; 2002 Sep; 88(3):285-9. PubMed ID: 12426498
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of repair resin type and surface treatment on the repair strength of heat-polymerized denture base resin.
    Alkurt M; Yeşil Duymuş Z; Gundogdu M
    J Prosthet Dent; 2014 Jan; 111(1):71-8. PubMed ID: 24161257
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the fitting accuracy of thermoplastic denture base resins used in non-metal clasp dentures to a conventional heat-cured acrylic resin.
    Wada J; Fueki K; Yatabe M; Takahashi H; Wakabayashi N
    Acta Odontol Scand; 2015 Jan; 73(1):33-7. PubMed ID: 25314120
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The impact of polymerization method on tensile bond strength between denture base and acrylic teeth.
    Hashem M; Binmgren MA; Alsaleem SO; Vellappally S; Assery MK; Sukumaran A
    J Contemp Dent Pract; 2014 May; 15(3):315-8. PubMed ID: 25307813
    [TBL] [Abstract][Full Text] [Related]  

  • 10. How some ridge shapes affect the fit of denture bases.
    AlTarakemah Y; Soderholm KJ
    Eur J Prosthodont Restor Dent; 2012 Dec; 20(4):184-90. PubMed ID: 23495561
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of curing cycle on the tensile strength of the bond between heat cured denture base acrylic resin and acrylic resin denture teeth.
    Dalal A; Juszczyk AS; Radford DR; Clark RK
    Eur J Prosthodont Restor Dent; 2009 Dec; 17(4):146-9. PubMed ID: 20158054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dimensional stability of complete denture permanent acrylic resin denture bases; A comparison of dimensions before and after a second curing cycle.
    Fenlon MR; Juszczyk AS; Rodriguez JM; Curtis RV
    Eur J Prosthodont Restor Dent; 2010 Mar; 18(1):33-8. PubMed ID: 20397501
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of packing types on the dimensional accuracy of denture base resin cured by the conventional cycle in relation to post-pressing times.
    Consani RL; Domitti SS; Mesquita MF; Consani S
    Braz Dent J; 2004; 15(1):63-7. PubMed ID: 15322648
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Linear dimensional change of heat-cured acrylic resin complete dentures after reline and rebase.
    Pow EH; Chow TW; Clark RK
    J Prosthet Dent; 1998 Aug; 80(2):238-45. PubMed ID: 9710829
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of the impact strength of the denture base resin polymerized by various processing techniques.
    Jadhav R; Bhide SV; Prabhudesai PS
    Indian J Dent Res; 2013; 24(1):19-25. PubMed ID: 23852228
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The influence of heat/pressure polymerization method on the adaptation of complete denture base].
    Wang YH; Zhang JZ; Pan J
    Shanghai Kou Qiang Yi Xue; 2006 Aug; 15(4):419-22. PubMed ID: 16955172
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Palatal vault depth influence on the flexural strength of two heat cure acrylic denture base resins: an in vitro study.
    Reddy BM; Himabindu M; Padmaja BI; Sunil M; Reddy NR
    J Contemp Dent Pract; 2013 Nov; 14(6):1131-6. PubMed ID: 24858763
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of different curing temperatures on the distortion at the posterior peripheral seal: an in vitro study.
    Pasam N; Hallikerimath RB; Arora A; Gilra S
    Indian J Dent Res; 2012; 23(3):301-4. PubMed ID: 23059563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of storage period and effect of different brands of acrylic resin on the dimensional accuracy of the maxillary denture base.
    Miéssi AC; Goiato MC; dos Santos DM; Dekon SF; Okida RC
    Braz Dent J; 2008; 19(3):204-8. PubMed ID: 18949291
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of trichloromethane on the bond strengths between acrylic teeth and different heat-cured denture bases: a comparative study.
    Bharat JS; Naidu DL; Reddy MV; Naveen P; Rao NV
    J Contemp Dent Pract; 2012 Nov; 13(6):850-5. PubMed ID: 23404015
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.