These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
122 related articles for article (PubMed ID: 23404643)
1. Can a central stitch over the Arantius' nodules provide a solution for preoperative severe native AI in LVAD patients. De Praetere H; Jacobs S; Rega F; Droogne W; Meyns B Int J Artif Organs; 2013 Mar; 36(3):220-4. PubMed ID: 23404643 [TBL] [Abstract][Full Text] [Related]
2. A modified Park's stitch to correct aortic insufficiency for bioprosthetic valve at time of left ventricular assist device implant: a case report. Kazui T; Sydow N; Friedman M; Kim S; Lick S; Khalpey Z J Cardiothorac Surg; 2016 Nov; 11(1):161. PubMed ID: 27899134 [TBL] [Abstract][Full Text] [Related]
3. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices. McKellar SH; Deo S; Daly RC; Durham LA; Joyce LD; Stulak JM; Park SJ J Thorac Cardiovasc Surg; 2014 Jan; 147(1):344-8. PubMed ID: 23246052 [TBL] [Abstract][Full Text] [Related]
4. Park's stitch for a bicuspid aortic valve in a patient on LVAD support. Maoz-Metzl D; Morsy M; Khalife WI; Lick SD J Card Surg; 2014 Nov; 29(6):843-5. PubMed ID: 25100071 [TBL] [Abstract][Full Text] [Related]
5. Influence of aortic valve opening in patients with aortic insufficiency after left ventricular assist device implantation. da Rocha E Silva JG; Meyer AL; Eifert S; Garbade J; Mohr FW; Strueber M Eur J Cardiothorac Surg; 2016 Mar; 49(3):784-7. PubMed ID: 26084757 [TBL] [Abstract][Full Text] [Related]
6. Efficacy and durability of central oversewing for treatment of aortic insufficiency in patients with continuous-flow left ventricular assist devices. Schechter MA; Joseph JT; Krishnamoorthy A; Finet JE; Ganapathi AM; Lodge AJ; Milano CA; Patel CB J Heart Lung Transplant; 2014 Sep; 33(9):937-42. PubMed ID: 24997496 [TBL] [Abstract][Full Text] [Related]
7. Safety and efficacy of aortic valvuloplasty for de novo aortic insufficiency in patients with a left-ventricular assist device. Tadokoro N; Kainuma S; Kawamoto N; Kakuta T; Tonai K; Shimizu H; Fujita T; Fukushima S Gen Thorac Cardiovasc Surg; 2024 May; 72(5):324-330. PubMed ID: 37709989 [TBL] [Abstract][Full Text] [Related]
8. Concomitant aortic valve repair with continuous-flow left ventricular assist devices: Results and implications. Fukuhara S; Takeda K; Chiuzan C; Han J; Polanco AR; Yuzefpolskaya M; Mancini DM; Colombo PC; Topkara VK; Kurlansky PA; Takayama H; Naka Y J Thorac Cardiovasc Surg; 2016 Jan; 151(1):201-9, 210.e1-2. PubMed ID: 26699773 [TBL] [Abstract][Full Text] [Related]
9. Surgical correction of aortic valve insufficiency after left ventricular assist device implantation. Atkins BZ; Hashmi ZA; Ganapathi AM; Harrison JK; Hughes GC; Rogers JG; Milano CA J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1247-52. PubMed ID: 23870154 [TBL] [Abstract][Full Text] [Related]
10. Percutaneous transcatheter aortic valve closure successfully treats left ventricular assist device-associated aortic insufficiency and improves cardiac hemodynamics. Parikh KS; Mehrotra AK; Russo MJ; Lang RM; Anderson A; Jeevanandam V; Freed BH; Paul JD; Karol J; Nathan S; Shah AP JACC Cardiovasc Interv; 2013 Jan; 6(1):84-9. PubMed ID: 23347865 [TBL] [Abstract][Full Text] [Related]
11. Pathological analysis of the aortic valve after long-term left ventricular assist device support. Hata H; Fujita T; Ishibashi-Ueda H; Nakatani T; Kobayashi J Eur J Cardiothorac Surg; 2014 Aug; 46(2):193-7. PubMed ID: 24335262 [TBL] [Abstract][Full Text] [Related]
12. Development of aortic insufficiency in patients supported with continuous flow left ventricular assist devices. Soleimani B; Haouzi A; Manoskey A; Stephenson ER; El-Banayosy A; Pae WE ASAIO J; 2012; 58(4):326-9. PubMed ID: 22569164 [TBL] [Abstract][Full Text] [Related]
13. The development of aortic insufficiency in continuous-flow left ventricular assist device-supported patients. Aggarwal A; Raghuvir R; Eryazici P; Macaluso G; Sharma P; Blair C; Tatooles AJ; Pappas PS; Bhat G Ann Thorac Surg; 2013 Feb; 95(2):493-8. PubMed ID: 23245444 [TBL] [Abstract][Full Text] [Related]
14. Aortic insufficiency in patients with sustained left ventricular systolic dysfunction after axial flow assist device implantation. Imamura T; Kinugawa K; Fujino T; Inaba T; Maki H; Hatano M; Kinoshita O; Nawata K; Kyo S; Ono M Circ J; 2015; 79(1):104-11. PubMed ID: 25381791 [TBL] [Abstract][Full Text] [Related]
15. Late aortic insufficiency related to poor prognosis during left ventricular assist device support. Toda K; Fujita T; Domae K; Shimahara Y; Kobayashi J; Nakatani T Ann Thorac Surg; 2011 Sep; 92(3):929-34. PubMed ID: 21871279 [TBL] [Abstract][Full Text] [Related]
16. Management of aortic valve insufficiency in patients supported by long-term continuous flow left ventricular assist devices. Morgan JA; Brewer RJ; Nemeh HW; Henry SE; Neha N; Williams CT; Lanfear DE; Tita C; Paone G Ann Thorac Surg; 2012 Nov; 94(5):1710-2. PubMed ID: 23098948 [TBL] [Abstract][Full Text] [Related]
17. Can Intraoperative Transesophageal Echocardiography Predict Postoperative Aortic Insufficiency in Patients Receiving Implantable Left Ventricular Assist Devices? Kellman SE; Feider AJ; Jeevanandam V; Chaney MA J Cardiothorac Vasc Anesth; 2015 Aug; 29(4):901-5. PubMed ID: 25939966 [TBL] [Abstract][Full Text] [Related]
19. Modified central closure technique for treatment of aortic insufficiency in patients on left ventricular assist device support. Morgan JA; Brewer RJ ASAIO J; 2012; 58(6):626-8. PubMed ID: 23103701 [TBL] [Abstract][Full Text] [Related]
20. Management of aortic insufficiency in patients with left ventricular assist devices: a simple coaptation stitch method (Park's stitch). Park SJ; Liao KK; Segurola R; Madhu KP; Miller LW J Thorac Cardiovasc Surg; 2004 Jan; 127(1):264-6. PubMed ID: 14752440 [No Abstract] [Full Text] [Related] [Next] [New Search]